Online Conductivity Controller LOCC-A10

Online Conductivity Controller LOCC-A10 features 3 points conductivity calibration system, TDS measurement mode, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, Temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. This controller measures Conductivity and TDS values in µS/ cm, and mS/ cm units.

  • Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cm
    Conductivity calibration points 1 to 3 points
    Conductivity accuracy ±1 % F.S.
    Conductivity resolution 0.001/ 0.01/ 0.1/ 1
    Conductivity calibration solutions 84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm
    TDS measurement range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS accuracy ±1 % F.S.
    TDS factor 0.1 to 1.0
    Temperature measurement range 0 to 100°C, 32 to 212°F
    Temperature accuracy 1°C
    Temperature resolution 0.1°C
    Temperature calibration points 1 point
    Temperature calibration range Measured value ± 10°C
    Signal output 4 to 200 mA
    Load Max. 500 Ω
    Low and high alarm limits 0.02 uS/ cm to 20.0 mS/ cm, selectable
    Interface RS485
    Connection terminals Detachable screw terminals
    Temperature compensation Automatic, 0 to 100°C , 32 to 212°F
    Cell constant K= 0.1, 1, 10
    Environmental conditions Ambient temperature to ≤ 60°C, RH ≤ 80%
    Reference temperature 25°C
    Display LCD
    Power DC 24 V
    Dimension (L*W*H) 96 × 96 × 75 mm
    Weight 350 g
    • Equipped with industrial conductivity electrode
    • 1 to 3 conductivity calibration points, 1 temperature calibration point
    • Selectable temperature units °C or °F for diff. applications
    • System menu allows setting of up to 9 parameters
    • Reset features to resumes all setting back to default
    • ATC mode for accurate readings over entire range
    • Low and high alarm limits set automatically activate an external device
    • Manual temperature calibration improves accuracy
  • Used to measure conductivity and TDS values required for quality checking and research purpose across water treatment plants, filtration units, RO treatment plants, Agriculture industry, Aquaculture industry and others.

  • Accessories no. Name Qty.
    1 Industrial Conductivity electrode 1
    2 Conductivity calibration solutions (bottle of 84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm) 1 each
  • Accessories no. Name Qty.
    1 Industrial Conductivity electrode for measuring pure water 1
    2 Industrial Conductivity electrode for measuring general liquids 1
    3 Industrial Conductivity electrode for measuring high conductivity liquids 1
    4 Conductivity calibration solutions (bottle of 84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm) 1 each

pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket pH tester LPPT-A10

  • 0.0 - 14.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point

Pocket pH tester LPPT-A12

  • 0.0 - 14.00 pHpH measurement range
  • Long distance planar pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point
Pocket pH tester LPPT-A11
  • 0.0 - 14.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point

Dissolved Oxygen Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket Dissolved oxygen tester LPKDO-A10
  • 0.0 to 20.0 mg/L (or ppm)Dissolved oxygen range
  • ± 0.5 mg/LDissolved oxygen accuracy
  • 0.0 to 200.0%% of saturation of oxygen
  • Polarographic dissolved oxygen probeSensor type

TDS Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket TDS tester LPTS-A12

  • 0.05 - 10.00 pptTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points

Pocket TDS tester LPTS-A10

  • 0.5 - 100.0 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points
Pocket TDS tester LPTS-A11
  • 5 - 1000 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points
BOD Meter LBOD-A10
  • 0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
    0 to 4000 mg/ L (need to dilute) (subsection measurement)
    Determination range
  • Less or less than 10 %Measurement error
  • 1 to 6Sample container/ bottle quantity
  • 1000 mlSample container/ bottle Capacity

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Multi-parameter Water Quality Meter LMPWM-A20

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
  • {"TDS range":"0-100 ppt. (max. 200 ppt., depending on factor setting)","TDS accuracy":"\u00b1 1 % F.S.","TDS factor":"0.1 - 1.0 (default 0.5)"}TDS measurement

Portable Multi-parameter Water Quality Meter LMPWM-A11

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"","Ion accuracy":"","Ion calibration points":"","Ion calibration solutions":""}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
Portable Multi-parameter Water Quality Meter LMPWM-A10
  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"0 to 19999 ppm, mg\/L, mol\/L","Ion accuracy":"\u00b1 0.5 % F.S. (monovalent), \u00b1 1 % F.S. (divalent)","Ion calibration points":"2 - 5 points","Ion calibration solutions":"0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol\/L, mg\/L"}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement