Pocket pH tester LPPT-A12

Pocket pH tester LPPT-A12 comes with 0.0 to 14.00 pH range. Its has long distance planar shape pH electrode. This pH tester has 2 points push button calibration system to automatically identify pH buffer. It is suitable for measuring pH of liquids and semi-solid substance in small vessels. Pocket pH meter is user friendly in nature & its waterproof performance protects the integrity of the instrument in harsh conditions.

  • pH measurement range 0.0 - 14.00 pH
    Shape of electrode Long distance planar pH electrode
    pH measurement accuracy ± 0.1 pH
    Calibration point 2 points
    Calibration solution USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
    Operating temperature
    Temperature accuracy
    Temperature compensation range
    Data hold function Manual or Automatic
    Connector 6 pin
    Shutdown mode Manual or automatic ( 8 minutes without key operations)
    Dimension (length × diameter) 185 × 40 mm
    Weight 100 g
    Power type 3 × 1.5 V G13A button battery 3
    Battery life About 150 hours
    • pH measurement range: 0.0 - 14.00 pH
      Long distance planar pH electrode
    • LCD screen display to show the readings
    • 2 points push button calibration to automatically identify pH buffer
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Automatic power off helps to reduce battery power consumption
    • Replaceable electrodes, cost effective maintenance
  • Pocket pH tester is suitable for measuring pH of water, waste water, potable water and other liquids and semi-solid substance in small vessels used in enviornmetal monitoring, agriculture, food & beverage industry.

  • pH standard buffer solutions (pH 4.0/7.00/10.01)
    G13A button battery
    Carrying box/case
  • pH standard buffer solutions USA (pH 4.0/7.00/10.01)
    Long distance planar shape pH electrode

Related Products of pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket pH tester LPPT-A20

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Multi purpose Pocket pH tester LPPT-B10

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Different electrodes can be connceted via BNC ConnectorShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A21

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point
Pocket pH tester LPPT-A32
  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Long distance planar pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point
Pocket pH tester LPPT-A30
  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A22

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Long distance planar pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A10

  • 0.0 - 14.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point

Pocket pH tester LPPT-A31

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point
Pocket pH tester LPPT-A11
  • 0.0 - 14.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point

Portable Water Hardness Meters

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable water hardness meter LPWM-A10

  • 0.05 mmol / L - 0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Water hardness range
  • ± 1 % F.S.Accuracy
  • 2 to 5 pointsCalibration points
  • 0.001, 0.01, 0.1 mmol / L, 0.001, 0.01, 0.1 mol / LCalibration solution

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for F, LBIM-A11

  • F range: 1 × 106M – saturation, 0.02 ppm to saturationIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Cl, LBIM-A10
  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Na, LBIM-A12
  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop pH meter LBPM-A11

  • 0.00 to 14.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 2 pointsCalibration points

Benchtop pH Meter LBPM-B11

  • 0 to 100°C, 32°F to 212°F Manual or AutomaticTemperature compensation
  • Manual or automatic endpoint detectionHold function
  • Standard or High-accuracyStability criteria
  • 10, 30, 60 seconds, 10, 30 minutes or OffInterval readings
Benchtop pH meter LBPM-A20
  • -1.00 to 15.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 1-3 pointsCalibration points
BOD Meter LBOD-A10
  • 0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
    0 to 4000 mg/ L (need to dilute) (subsection measurement)
    Determination range
  • Less or less than 10 %Measurement error
  • 1 to 6Sample container/ bottle quantity
  • 1000 mlSample container/ bottle Capacity

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

  • 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Water hardness range
  • ± 1 % F.S.Accuracy
  • 2 to 5 pointsCalibration points
  • 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/LCalibration solution