Pocket pH tester LPPT-A32

Pocket pH tester LPPT-A30 comes with 0.0 to 15.00 pH range. It has long distance planar shape pH electrode. It is suitable for measuring pH of liquids, solutions. Equipped with reset function to restore settings to default mode. This pH tester series comes with 1 - 3 points push button calibration system to automatically identify pH buffer. It has temperature accuracy ± 1 °C. Its built–in system menu can customize up to five parameters.

  • pH measurement range pH range: (-1.00) to 15.00 pH
    Shape of electrode Long distance planar pH electrode
    pH measurement accuracy ± 0.01 pH
    Calibration point 1 - 3 points
    Calibration solution USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
    Operating temperature 0 °C to 60 °C, 32 °F to 140 °F
    Temperature accuracy ± 1 °C
    Temperature compensation range 0 °C to 60 °C, Automatic
    Data hold function Manual or Automatic
    Connector 6 pin
    Shutdown mode Manual or automatic ( 8 minutes without key operations)
    Dimension (length × diameter) 185 × 40 mm
    Weight 100 g
    Power type 2 × 1.5 V AAA batteries
    Battery life About 200 hours
    • pH measurement range: 0.0 - 15.00 pH
      Long distance shape pH electrode
    • LCD screen display to show the readings
    • Temperature accuracy ± 1 °C
    • 1 - 3 points push button calibration to automatically identify pH buffer
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Automatic power off to reduce battery power consumption
    • Reset function to restore settings to default mode
    • Replaceable electrodes, cost effective maintenance
    • Alarm icon to indicate low battery
  • Pocket pH tester with temperature accuracy is suitable for measuring pH of water, waste water, potable water and other liquids and semi-solid substance in small vessels used in enviornmetal monitoring, agriculture, food & beverage industry.

  • pH standard buffer solutions (pH 4.0/7.00/10.01)
    AAA button battery
    Carrying box/case
  • long distance planar shape pH electrode
    pH standard buffer USA (pH 4.01/7.00/10.01), NIST (pH 4.01/6.86/9.18)

Related Products of pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Multi purpose Pocket pH tester LPPT-B10

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Different electrodes can be connceted via BNC ConnectorShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A30

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A11

  • 0.0 - 14.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point
Pocket pH tester LPPT-A20
  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point
Pocket pH tester LPPT-A10
  • 0.0 - 14.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point

Pocket pH tester LPPT-A21

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

Pocket pH tester LPPT-A12

  • 0.0 - 14.00 pHpH measurement range
  • Long distance planar pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point

Pocket pH tester LPPT-A31

  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point
Pocket pH tester LPPT-A22
  • pH range: (-1.00) to 15.00 pHpH measurement range
  • Long distance planar pH electrodeShape of electrode
  • ± 0.01 pHpH measurement accuracy
  • 1 - 3 pointsCalibration point

pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket pH tester LPPT-A10

  • 0.0 - 14.00 pHpH measurement range
  • Round glass pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point

Pocket pH tester LPPT-A12

  • 0.0 - 14.00 pHpH measurement range
  • Long distance planar pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point
Pocket pH tester LPPT-A11
  • 0.0 - 14.00 pHpH measurement range
  • Flat pH electrodeShape of electrode
  • ± 0.1 pHpH measurement accuracy
  • 2 pointsCalibration point
Multi parameter water quality analyzer LMWA-A10
  • {"COD determination range":"2 to 10000 mg\/ L","COD measurement accuracy":"COD < 50 mg\/ L, \u2264 \u00b1 10 % \nand \nCOD > 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}COD
  • {"Ammonia nitrogen determination range":"0.02 to 60 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}Ammonia nitrogen
  • {"Total phosphorous determination range":"0.002 to 20 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}Total phosphorous
  • {"Turbidity determination range":"0.5 to 400 NTU","Turbidity measurement accuracy":"\u2264 \u00b1 5 %","Turbidity minimum detection limit":"0.1 NTU","Turbidity measurement time":"1 minute","Turbidity repeatability":"\u2264 \u00b1 5 %","Consumables for colorimetric turbidity measurement":"Colorimetric Cuvette"}Turbidity

Multi parameter water quality analyzer LMWA-A11

  • {"COD determination range":"5 to 5000 mg\/ L","COD measurement accuracy":"COD < 50 mg\/ L, \u2264 \u00b1 10 % \nand \nCOD > 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}COD
  • {"Ammonia nitrogen determination range":"0.02 to 30 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"20 pcs","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}Ammonia nitrogen
  • {"Total phosphorous determination range":"0.002 to 10 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}Total phosphorous
  • {"Turbidity determination range":"0.5 to 400 NTU","Turbidity measurement accuracy":"\u2264 \u00b1 5 %","Turbidity minimum detection limit":"0.1 NTU","Turbidity measurement time":"1 minute","Turbidity repeatability":"\u2264 \u00b1 5 %","Consumables for colorimetric turbidity measurement":"Colorimetric Cuvette"}Turbidity

Online Conductivity Controller LOCC-A10

  • 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cmConductivity measurement range
  • 1 to 3 pointsConductivity calibration points
  • ±1 % F.S.Conductivity accuracy
  • 0.001/ 0.01/ 0.1/ 1Conductivity resolution

pH Meters (Portable)

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable pH/ORP meter LPRPM-A11
  • (-2.00) to 20.00 pHpH range
  • ± 0.002 pHpH accuracy
  • 0.1, 0.01, 0.001 pHpH resolution
  • 1 - 5 pointsCalibration points
Portable pH meter LPRPM-A10
  • (-2.00) to 16.00 pHpH range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 2 pointsCalibration points

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

  • 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Water hardness range
  • ± 1 % F.S.Accuracy
  • 2 to 5 pointsCalibration points
  • 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/LCalibration solution