Portable Dissolved oxygen meter LPRDO-A10

Portable Dissolved oxygen meter LPRDO-A10 is equipped with polarographic sensor to measure the dissolved oxygen content. The manual salinity & barometric pressure compensation helps in accurate measurement of dissolved oxygen. It can store up to 48 sets of data & it is transferrable to PC via USB interface. Due to its portable nature this meter can be used across water purification plants, waste water management plants for testing & quality analysis.

  • Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
    Dissolved oxygen accuracy ± 0.5 mg / L
    Resolution 0.1 mg / L
    Calibration points 1 - 2 points
    Sensor type Polarographic DO probe
    Temperature compensation range 0 to 40 °C, 32 °F to 104 °F
    Barometric pressure correction 60.0 to 112.5 kPa, 450 to 850 mmHg
    Salinity correction 0 - 35 g / L
    % of saturation of oxygen range 0.0 to 200.0 %
    % of saturation of oxygen accuracy ± 10 % F.S.
    % of saturation of oxygen resolution 0.001
    System menu
    Data hold function Manual
    Power off
    Reset function Yes
    Memory Stores up to 48 sets of data
    Output USB communication interface
    Display LCD screen
    Connector 4-pin mini plug
    Calibration due
    Stability connector
    Battery life Approximately 150 hours
    Power 1 x 9 V / 800 mA battery
    Dimension (L x W x H) 185 × 88 × 32 mm
    Weight 300 g
    • Equipped with polarographic sensor & LCD display
    • 1-2 points calibration using air saturated water & zero oxygen solution
    • Manual salinity & barometric pressure compensation for better measurement of dissolved oxygen
    • Stores up to 48 sets of data
    • Data is transferrable to PC via USB interface
    • Built-in real time clock stamps stores data to meet GLP standard
    • Automatic temperature compensation for accurate measured value over the entire range
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Reset function automatically resumes all the settings to default mode
    • Help message as an operational guide for quick beginning to the dissolved oxygen meter
  • Portable dissolved oxygen meter has applications in water & waste water management industry, environmental monitoring, surface ground water, research & development, education to detect content of dissolved oxygen.

  • Dissolved oxygen probe
    Dissolved oxygen Electrolyte solution
    Membrane cap
    1 x 9 V/ 800 mA battery
    Carrying case
  • Polarographic sensor
    30 mL electrolyte solution per bottle
    Membrane cap

Related Products of Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable dissolved oxygen meter LPRDO-A11

  • 0.0 - 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable dissolved oxygen meter LPRDO-A11

  • 0.0 - 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points

Portable Dissolved oxygen meter LPRDO-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points

Salinity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket Salinity tester LPST-A11
  • 0.00 to 80.00 pptSalinity measurement range
  • ± 1 % F.SSalinity accuracy
  • 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cmConductivity range
  • 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cmCalibration solutions
Pocket Salinity tester LPST-A10
  • 0.00 to 10.00 pptSalinity measurement range
  • ± 1 % F.SSalinity accuracy
  • 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cmConductivity range
  • 84 µS/cm, 1413 µS/cm, 12.88 mS/cmCalibration solutions

Portable Turbidity Meter LTM-A10

  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume

Portable turbidity meter LTM-A16

  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range
Portable Turbidity Meter LTM-A11
  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume

pH Meters (Portable)

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable pH/ORP meter LPRPM-A11
  • (-2.00) to 20.00 pHpH range
  • ± 0.002 pHpH accuracy
  • 0.1, 0.01, 0.001 pHpH resolution
  • 1 - 5 pointsCalibration points

Portable pH meter LPRPM-A10

  • (-2.00) to 16.00 pHpH range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 2 pointsCalibration points

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket Conductivity tester LPCT-A12

  • 0.1 to 19.99 mS/cmConductivity measurement range
  • High range conductivityType of conductivity
  • ± 1 % F.S.Conductivity accuracy
  • 1 pointConductivity calibration points
Pocket Conductivity tester LPCT-A11
  • 10 to 1999 µS/cmConductivity measurement range
  • Mid-range conductivityType of conductivity
  • ± 1 % F.S.Conductivity accuracy
  • 1 pointConductivity calibration points
Pocket Conductivity tester LPCT-A10
  • 1.0 to 199.9 µS/cmConductivity measurement range
  • Low range conductivityType of conductivity
  • ± 1 % F.S.Conductivity accuracy
  • 1 pointConductivity calibration points