Portable Turbidity Meter LTM-A11

Portable Turbidity meter LTM-A11 with microprocessor controlled system, utilizes 90° scattered light principle to measure water turbidity in nephelometric turbidity unit i.e. NTU. The formazine standard solution of turbidity mentioned in ISO 7027 is used for turbidity analysis. Portable meter, used in field and lab scale analysis, delivers highly accurate results as per the GLP standards.

  • Measuring range (NTU) 0 to 100, 0 to 200
    Minimum readout value (NTU) 0.01, 0.1
    Calibration point 4
    Sample volume 5 to 10 ml
    Principle method 90° scattered light
    Operating temperature 5 to 40°C
    Working temperature 5 to 40°C
    Light source Infrared-emitting diode (850 nm λ)
    Detector Silicon photodiode
    Error value ± 6 % (± 2 % F.S)
    Zero drift ± 0.5 % F.S.
    Reset functions Yes
    Memory Stores up to 20 sets data
    Output
    Dimension 370 × 260 × 150 mm
    Weight 1.5 kg
    Power batteries DC 1.5 V, 5 AA alkaline batteries
    Power supply AC 220 V, 50 Hz
    • Quick and automatic multi-points calibration
    • LCD display with touch keypad
    • Non- linear data processing and transfer
    • Selectable automatic or manual switch mode
    • High through put stability
    • Auto shut down system
    • Easy to use
    • Standard carrying case for field analysis
  • Used to test turbidity of water across water testing plants, water recycling units, and food and beverage units as a quality and research parameter.

  • Accessory No. Name Quantity
    1 Specimen bottle 3 pcs
    2 400 NTU (Formazine) turbidity standard solution 1 bottle
    3 Power cable 1 pc
    4 Carrying box 1 pc
  • Accessory No. Name
    1 USB communication interface

Portable Turbidity Meter LTM-A14

  • 0 to 100, 100 to 800Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 6Calibration point
  • 5 to 10 mlSample volume

Portable turbidity meter LTM-A16

  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range

Portable Turbidity Meter LTM-A15

  • 0 to 100, 100 to 1000Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 7Calibration point
  • 5 to 10 mlSample volume
Bench top Turbidity Meter (with built-in printer) LTM-C13
  • 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000Measuring range (NTU)
  • 0.01Minimum readout value (NTU)
  • 5Calibration point
  • 18 to 20 mlSample volume
Portable Turbidity Meter LTM-A13
  • 0 to 100, 100 to 500Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 6Calibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter LTM-B12

  • 0 to 50, 0 to 100, 0 to 200, 0 to 400Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter (with built-in printer) LTM-C12

  • 0 to 10, 0 to 100, 0 to 200, 0 to 500Measuring range (NTU)
  • 0.001Minimum readout value (NTU)
  • 4Calibration point
  • 18 to 20 mlSample volume

Portable Turbidity Meter LTM-A12

  • 0 to 100, 100 to 400Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 5Calibration point
  • 5 to 10 mlSample volume
Bench top Turbidity Meter (with built-in printer) LTM-C10
  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01Minimum readout value (NTU)
  • 2Calibration point
  • 18 to 20 mlSample volume
Bench top Turbidity Meter LTM-B10
  • 0 to 100Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 1Calibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter LTM-B11

  • 0 to 50, 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 3Calibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter (with built-in printer) LTM-C11

  • 0 to 100, 0 to 200, 0 to 500Measuring range (NTU)
  • 0.01Minimum readout value (NTU)
  • 3Calibration point
  • 18 to 20 mlSample volume

Bench top Turbidity Meter (with built-in printer) LTM-C14

  • 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000Measuring range (NTU)
  • 0.001Minimum readout value (NTU)
  • 5Calibration point
  • 18 to 20 mlSample volume
Bench top Turbidity Meter LTM-B13
  • 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 5Calibration point
  • 5 to 10 mlSample volume
Portable Turbidity Meter LTM-A10
  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable dissolved oxygen meter LPRDO-A11

  • 0.0 - 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points

Portable Dissolved oxygen meter LPRDO-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points
Benchtop Multi-parameter Water Quality Meter LMPWM-A31
  • pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
    pH Mode
  • mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
    mV Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
    Conductivity Mode
  • TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
    TDS Mode
Benchtop Multi-parameter Water Quality Meter LMPWM-A32
  • pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
    pH Mode
  • mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
    mV Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
    Conductivity Mode
  • Dissolved Oxygen Range 0.00 to 20.00 mg/ L
    Dissolved Oxygen Accuracy ± 0.2 mg/ L
    Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable
    Dissolved Oxygen Calibration Points 1 or 2 Points
    % Saturation Range 0.0 to 200.0 % with ± 2 % accuracy
    Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg
    Salinity correction 0 to 50 g/ L
    Dissolved Oxygen Mode

Benchtop Multi-parameter Water Quality Meter LMPWM-A30

  • pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
    pH Mode
  • mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
    mV Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
    Conductivity Mode
  • TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
    TDS Mode

Online pH Controller LOPC-A10

  • 01.00 to 15.00 pHpH measurement range
  • 1 to 3 pointspH calibration points
  • USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)pH Buffer Solutions
  • ± 0.01 pHpH accuracy
Water Activity Meter with sensor LWAM-A10
  • Water activity 0 to 0.980 aw (no condensing )Measuring range
  • 0 to 50°CTemperature range
  • ± 0.015 awMeasurement accuracy
  • ± 0.5°CTemperature accuracy
Water Activity Meter LWTM-A10
  • 0 to 1.0 awRange
  • 0 to 1.0 awResolution
  • ± 0.02 awAccuracy
  • Nonconductive humidity sensorSensor

Online Dissolved Oxygen Controller LODC-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • 1 - 2 pointsDissolved oxygen Calibration points
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LDissolved oxygen resolution