Benchtop Conductivity Meter LBCM-A13

Benchtop Conductivity Meter LBCM-A13 with 7 inch display conducts up to 5 point calibration, automatically recognizes calibration standards. Comes with 03 reading mode: fast, medium, strict, custom to balance the work operations. Complied with GLP specifications, meter allows user to carry data statistics, measure results, carry out and review, analyze, and compare statistics.

  • Conductivity measurement range 0.000 μS/cm to 3000mS/cm
    Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
    TDS measurement range 0.000 mg/L to 1000g/L
    Salinity measurement range 0.00 to 8.00 %
    Temperature measurement range -5.0 to 135.0 °C
    Conductivity accuracy ± 0.5 % FS
    Resistivity accuracy ± 0.5 % FS
    TDS accuracy ± 0.5 % FS
    Salinity accuracy ± 0.1 %
    Temperature accuracy ± 0.1  °C
    Automatic temperature compensation Yes
    Automatic calibration Yes
    Automatic range switching Yes
    Calibration function Yes
    Reading mode
    Timed reading Yes
    Balanced reading Yes
    Continuous reading Yes
    Data interface RS232, USB
    Data storage 1000 sets
    Complied with GLP specifications Yes
    Power supply (Input: AC 100 to 240 V, 1.35 A) (Output: DC 24 V, 3A)
    Dimension 280 × 280 × 130 mm
    Weight 2.5 kg
    • 7 inch color touch screen
    • Automatic temperature compensation and calibration
    • Electrode correction function
    • 5 point conductivity calibrations
    • Intelligent operating system
    • 100 sets of measurement data
    • Different conductivity compensation methods (includes pure water)
    • Different salinity compensation methods (includes saline , brine water)
    • Supports USB, RS232 connection with PC, serial printer
    • Supports firmware upgrade, support U disk hot swap
  • Used to test Conductivity, TDS, Salinity, resistivity values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose.

  • Accessories no. Name
    1 Conductivity Electrode
    2 Temperature sensor
    3 Electrode holder
    4 AC/DC Power Adapter
    5 USB Communication Line
  • Accessories No. Name
    1 Conductivity Probe (K=0.01)
    2 Conductivity Probe (K=0.1)
    3 Conductivity Probe (K=1)
    4 Conductivity Probe (K=10)

Related Products of Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11

  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cmConductivity measurement range
  • ± 1 % F.S.Conductivity accuracy
  • 0.01, 0.1, 1Conductivity resolution
  • 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cmConductivity calibration solutions

Benchtop Conductivity Meter LBCM-A14

  • {"Conductivity measurement range":"0.01-20.0, 200.0, 2000 \u00b5S\/cm, 20.00, 200.0 mS\/cm","Conductivity accuracy":"\u00b11% F.S.","Conductivity resolution":"0.001, 0.01, 0.1, 1","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm , 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm"}Conductivity Mode
  • {"TDS measurement Range":"0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS Accuracy":"\u00b1 1 % F.S.","TDS Factor":"0.01 to 1.00 (default 0.5)","TDS Calibration points":"3 points"}TDS Mode
  • {"Temperature range":"0 to 105\u00b0C, 32 to 221\u00b0F","Temperature accuracy":"\u00b11\u00b0C","Temperature resolution":"0.1\u00b0C, 0.1\u00b0F","Temperature calibration points":"1 point","Temperature Compensation Range and Mode":"Manual or Automatic, 0 to 100\u00b0C , 32 to 212\u00b0F","Temperature coefficient":"0.0 to 10.0 % per \u00b0C"}Temperature Mode
  • K=0.1, 1, 10Cell constant

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable dissolved oxygen meter LPRDO-A11

  • 0.0 - 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points

Portable Dissolved oxygen meter LPRDO-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points

pH Meters (Portable)

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable pH/ORP meter LPRPM-A11
  • (-2.00) to 20.00 pHpH range
  • ± 0.002 pHpH accuracy
  • 0.1, 0.01, 0.001 pHpH resolution
  • 1 - 5 pointsCalibration points
Portable pH meter LPRPM-A10
  • (-2.00) to 16.00 pHpH range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 2 pointsCalibration points

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

  • 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Water hardness range
  • ± 1 % F.S.Accuracy
  • 2 to 5 pointsCalibration points
  • 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/LCalibration solution

Portable Turbidity Meter LTM-A11

  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume
Portable Turbidity Meter LTM-A10
  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume
Portable turbidity meter LTM-A16
  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range

Dissolved Oxygen Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket Dissolved oxygen tester LPKDO-A10

  • 0.0 to 20.0 mg/L (or ppm)Dissolved oxygen range
  • ± 0.5 mg/LDissolved oxygen accuracy
  • 0.0 to 200.0%% of saturation of oxygen
  • Polarographic dissolved oxygen probeSensor type