Pocket ORP tester LPOT-A10

Pocket ORP tester LPOT-A10 is easy to use ORP meter equipped with a platinum sensor. It is suitable for measuring the oxidation reduction potential of liquids. The relative & absolute mV measurement modes are possible with this pocket ORP meter.

  • Sensor type Platinum sensor
    Connector 6 pin
    ORP measurement range (-999) to 999 mV
    ORP accuracy ± 2 mV
    ORP resolution 1 mV
    ORP calibration solutions mV & relative mV
    ORP calibration points 1 point (only for relative mV mode)
    Data hold function Manual or automatic endpoint detection
    Reset function Yes
    Display LCD screen
    Power off Manual or automatic (8 minutes after last key is pressed)
    Power 2 × 1.5V “AAA” batteries
    Battery life 200 hours
    Dimension (L*dia.) 175 × 40 mm
    Weight 100 g
    • Equipped with a platinum sensor
    • Equipped with 6 pin connector
    • 1 point offset calibration for adjusting display value to known standards
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Automatic power off helps to reduce battery power consumption
    • Reset function automatically resumes all the setting back to factory default options
    • Waterproof features guarantees protection against harsh conditions
  • Pocket ORP tester can be used for measurement of chromate reduction, cyanide oxidation, redox & oxidation reaction content in swimming pool water, aquaculture industry and drinking water.

  • ORP electrode
    AAA batteries
    Carrying case
    Plastic storage bottles
  • High purity platinum electorde

Related Products of ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket ORP tester LPOT-A11

  • BNCConnector
  • (-999) to 999 mVORP measurement range
  • ± 2 mVORP accuracy
  • 1 mVORP resolution

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop pH meter LBPM-A20

  • -1.00 to 15.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 1-3 pointsCalibration points

Benchtop pH meter LBPM-A11

  • 0.00 to 14.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 2 pointsCalibration points
Benchtop pH Meter LBPM-B11
  • 0 to 100°C, 32°F to 212°F Manual or AutomaticTemperature compensation
  • Manual or automatic endpoint detectionHold function
  • Standard or High-accuracyStability criteria
  • 10, 30, 60 seconds, 10, 30 minutes or OffInterval readings

pH Meters (Portable)

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable pH/ORP meter LPRPM-A11
  • (-2.00) to 20.00 pHpH range
  • ± 0.002 pHpH accuracy
  • 0.1, 0.01, 0.001 pHpH resolution
  • 1 - 5 pointsCalibration points

Portable pH meter LPRPM-A10

  • (-2.00) to 16.00 pHpH range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 2 pointsCalibration points

Portable Conductivity Meter LPCM-A10

  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation
  • LinearTemperature coefficient
Portable Conductivity Meter LPCM-A11
  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"TDS range":"0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS accuracy":"\u00b11 % F.S","TDS factor":"0.01 to 1.00 (Default 0.5)","TDS resolution":"0.01, 0.1, 1"}TDS
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation
Portable Conductivity Meter LPCM-A12
  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Salinity range":"0.00 to 80.00 ppt, 0.00 to 42.00 psu","Salinity accuracy":"\u00b11% F.S","Salinity measurement modes":"Practical Salinity (psu) or Natural Seawater (ppt)","Salinity resolution":"0.01, 0.1, 1"}Salinity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation

Online pH Controller LOPC-A10

  • 01.00 to 15.00 pHpH measurement range
  • 1 to 3 pointspH calibration points
  • USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)pH Buffer Solutions
  • ± 0.01 pHpH accuracy

Multi parameter water quality analyzer LMWA-A11

  • {"COD determination range":"5 to 5000 mg\/ L","COD measurement accuracy":"COD < 50 mg\/ L, \u2264 \u00b1 10 % \nand \nCOD > 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}COD
  • {"Ammonia nitrogen determination range":"0.02 to 30 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"20 pcs","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}Ammonia nitrogen
  • {"Total phosphorous determination range":"0.002 to 10 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}Total phosphorous
  • {"Turbidity determination range":"0.5 to 400 NTU","Turbidity measurement accuracy":"\u2264 \u00b1 5 %","Turbidity minimum detection limit":"0.1 NTU","Turbidity measurement time":"1 minute","Turbidity repeatability":"\u2264 \u00b1 5 %","Consumables for colorimetric turbidity measurement":"Colorimetric Cuvette"}Turbidity
Multi parameter water quality analyzer LMWA-A10
  • {"COD determination range":"2 to 10000 mg\/ L","COD measurement accuracy":"COD < 50 mg\/ L, \u2264 \u00b1 10 % \nand \nCOD > 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}COD
  • {"Ammonia nitrogen determination range":"0.02 to 60 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}Ammonia nitrogen
  • {"Total phosphorous determination range":"0.002 to 20 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}Total phosphorous
  • {"Turbidity determination range":"0.5 to 400 NTU","Turbidity measurement accuracy":"\u2264 \u00b1 5 %","Turbidity minimum detection limit":"0.1 NTU","Turbidity measurement time":"1 minute","Turbidity repeatability":"\u2264 \u00b1 5 %","Consumables for colorimetric turbidity measurement":"Colorimetric Cuvette"}Turbidity