Online pH Controller LOPC-A10

Online pH Controller LOPC-A10 features 1 to 3 points pH calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. The automatic electrode slope display helps user decide when to replace the sensor.

  • pH measurement range 01.00 to 15.00 pH
    pH calibration points 1 to 3 points
    pH Buffer Solutions USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
    pH accuracy ± 0.01 pH
    pH resolution 0.01 pH
    mV measurement range -1000 to 1000 mV
    mV accuracy ± 1 mV
    mV resolution 1 mV
    Temperature range 0 to 100°C , 32 to 212°F
    Temperature calibration points 1 point
    Temperature calibration range ± 10°C
    Temperature accuracy ± 1°C
    Temperature resolution 0.1°C
    Signal output 4 to 20 mA
    Load Max 500
    Low and high alarm limits 1.00 to 10.00 pH, selectable
    Connection Interface RS485
    Connection Terminals Detectable screw terminals
    Temperature compensation Automatic, 0 to 100°C , 32 to 212°F
    Environmental conditions Ambient temperature to ≤ 60°C, RH ≤ 80%
    Display LCD
    Power DC 24 V
    Dimension (L*W*H) 96 × 96 × 75 mm
    Weight 350 g
    • Equipped with industrial pH electrode
    • 1 to 3 pH calibration points with ‘Automatic buffer recognition’
    • ATC mode for accurate readings over entire range
    • Low high alarm limits set automatically activate an external device
    • Selectable temperature units °C or °F for diff. applications
    • System menu allows setting of up to 9 parameters
    • Reset features to resumes all setting back to default
    • Manual temperature calibration improves accuracy
  • Used to measure pH in waste water treatment and quality inspection plants, filtration systems, RO treatment water plants, Agriculture, Aquaculture, and research industry.

  • Accessories No. Name Qty.
    1 Industrial pH electrode 1
    2 pH buffer pouches (pH 4.01, 7.00, 10.01) 1

Portable Turbidity Meter LTM-A10

  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume

Portable Turbidity Meter LTM-A11

  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume
Portable turbidity meter LTM-A16
  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range
Water Activity Meter LWTM-A10
  • 0 to 1.0 awRange
  • 0 to 1.0 awResolution
  • ± 0.02 awAccuracy
  • Nonconductive humidity sensorSensor

Water Activity Meter with sensor LWAM-A10

  • Water activity 0 to 0.980 aw (no condensing )Measuring range
  • 0 to 50°CTemperature range
  • ± 0.015 awMeasurement accuracy
  • ± 0.5°CTemperature accuracy

Multi parameter water quality analyzer LMWA-A10

  • {"COD determination range":"2 to 10000 mg\/ L","COD measurement accuracy":"COD < 50 mg\/ L, \u2264 \u00b1 10 % \nand \nCOD > 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}COD
  • {"Ammonia nitrogen determination range":"0.02 to 60 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}Ammonia nitrogen
  • {"Total phosphorous determination range":"0.002 to 20 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}Total phosphorous
  • {"Turbidity determination range":"0.5 to 400 NTU","Turbidity measurement accuracy":"\u2264 \u00b1 5 %","Turbidity minimum detection limit":"0.1 NTU","Turbidity measurement time":"1 minute","Turbidity repeatability":"\u2264 \u00b1 5 %","Consumables for colorimetric turbidity measurement":"Colorimetric Cuvette"}Turbidity
Multi parameter water quality analyzer LMWA-A11
  • {"COD determination range":"5 to 5000 mg\/ L","COD measurement accuracy":"COD < 50 mg\/ L, \u2264 \u00b1 10 % \nand \nCOD > 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}COD
  • {"Ammonia nitrogen determination range":"0.02 to 30 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"20 pcs","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}Ammonia nitrogen
  • {"Total phosphorous determination range":"0.002 to 10 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}Total phosphorous
  • {"Turbidity determination range":"0.5 to 400 NTU","Turbidity measurement accuracy":"\u2264 \u00b1 5 %","Turbidity minimum detection limit":"0.1 NTU","Turbidity measurement time":"1 minute","Turbidity repeatability":"\u2264 \u00b1 5 %","Consumables for colorimetric turbidity measurement":"Colorimetric Cuvette"}Turbidity
Online pH Controller LOPC-A10
  • 01.00 to 15.00 pHpH measurement range
  • 1 to 3 pointspH calibration points
  • USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)pH Buffer Solutions
  • ± 0.01 pHpH accuracy

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11

  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cmConductivity measurement range
  • ± 1 % F.S.Conductivity accuracy
  • 0.01, 0.1, 1Conductivity resolution
  • 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cmConductivity calibration solutions

Benchtop Conductivity Meter LBCM-A13

  • 0.000 μS/cm to 3000mS/cmConductivity measurement range
  • 5.00 Ω·cm to 100.0 MΩ·cmResistivity measurement range
  • 0.000 mg/L to 1000g/LTDS measurement range
  • 0.00 to 8.00 %Salinity measurement range
Benchtop Conductivity Meter LBCM-A14
  • {"Conductivity measurement range":"0.01-20.0, 200.0, 2000 \u00b5S\/cm, 20.00, 200.0 mS\/cm","Conductivity accuracy":"\u00b11% F.S.","Conductivity resolution":"0.001, 0.01, 0.1, 1","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm , 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm"}Conductivity Mode
  • {"TDS measurement Range":"0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS Accuracy":"\u00b1 1 % F.S.","TDS Factor":"0.01 to 1.00 (default 0.5)","TDS Calibration points":"3 points"}TDS Mode
  • {"Temperature range":"0 to 105\u00b0C, 32 to 221\u00b0F","Temperature accuracy":"\u00b11\u00b0C","Temperature resolution":"0.1\u00b0C, 0.1\u00b0F","Temperature calibration points":"1 point","Temperature Compensation Range and Mode":"Manual or Automatic, 0 to 100\u00b0C , 32 to 212\u00b0F","Temperature coefficient":"0.0 to 10.0 % per \u00b0C"}Temperature Mode
  • K=0.1, 1, 10Cell constant