Benchtop Dissolved oxygen meter LBDO-A10

Benchtop Dissolved oxygen meter LBDO-A10 is equipped with polarographic sensor to measure the dissolved oxygen content. The manual salinity & barometric pressure compensation helps in accurate measurement of dissolved oxygen. The system menu of dissolved oxygen meter can set 6 parameters which includes the number of calibration points, temperature units etc.

  • Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
    Dissolved oxygen accuracy ± 0.5 mg / L
    Resolution 0.1 mg / L
    Calibration points 1 - 2 points
    Sensor type Polarographic DO probe
    Temperature compensation range 0 to 40 °C, 32 to 104 °F
    Barometric pressure correction 60.0 to 112.5 kPa, 450 to 850 mmHg
    Salinity correction 0 - 35 g / L
    % of saturation of oxygen range 0.0 to 200.0 %
    % of saturation of oxygen accuracy ± 10 % F.S.
    % of saturation of oxygen resolution 0.001
    System menu Allows setting of 6 parameters
    Data hold function Manual or automatic endpoint detection
    Power off Manual or automatic (180 minutes)
    Reset function Yes
    Memory
    Display Backlit LCD (135 × 75 mm)
    Connector 6 pin mini plug
    Stability conditions
    Calibration due
    Power DC 9 V, use of SC adapter, AC 220 V / 50 Hz
    Dimension (L × W × H) 210 × 205 × 75 mm
    Weight 1.5 kg
    • Equipped with polarographic sensor
    • Equipped with large backlit LCD display
    • 1-2 points calibration using air saturated water & zero oxygen solution
    • Manual salinity & barometric pressure compensation for better measurement of dissolved oxygen
    • System menu allows setting the 6 optional parameters
    • Automatic temperature compensation for accurate measured value over the entire range
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Reset function automatically resumes all the settings to default mode
    • Help message as an operational guide for quick beginning to the dissolved oxygen meter
  • Benchtop dissolved oxygen meter has applications in water & waste water management industry, environmental monitoring, surface ground water, research & development, education to detect content of dissolved oxygen.

  • Dissolved oxygen probe
    Dissolved oxygen Electrolyte solution
    Membrane cap
    DC 9 V power adapter
  • Polarographic sensor
    30 mL electrolyte solution per bottle
    Membrane cap

Related Products of Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A11

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points

Online Dissolved Oxygen Controller LODC-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • 1 - 2 pointsDissolved oxygen Calibration points
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LDissolved oxygen resolution

Benchtop Multi-parameter Water Quality Meter LMPWM-A32

  • pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
    pH Mode
  • mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
    mV Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
    Conductivity Mode
  • Dissolved Oxygen Range 0.00 to 20.00 mg/ L
    Dissolved Oxygen Accuracy ± 0.2 mg/ L
    Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable
    Dissolved Oxygen Calibration Points 1 or 2 Points
    % Saturation Range 0.0 to 200.0 % with ± 2 % accuracy
    Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg
    Salinity correction 0 to 50 g/ L
    Dissolved Oxygen Mode
Benchtop Multi-parameter Water Quality Meter LMPWM-A30
  • pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
    pH Mode
  • mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
    mV Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
    Conductivity Mode
  • TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
    TDS Mode
Benchtop Multi-parameter Water Quality Meter LMPWM-A31
  • pH range -2.00 to 20.00 pH
    pH Accuracy ± 0.002 pH
    pH Resolution 0.1/0.01/0.001 pH, selectable
    pH Calibration Points 1 to 5 Points
    pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
    pH Mode
  • mV Range -1999.9 to 1999.9 mV
    mV Accuracy ± 0.2 mV
    mV Resolution 0.1/1 mV, selectable
    mV Calibration Points 1 Point
    mV Mode
  • Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
    Conductivity Accuracy ± 0.5% F.S.
    Conductivity Resolution 0.01/0.1/1
    Conductivity Calibration Points 1 to 5 Points
    Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
    Conductivity Temperature coefficient 0.0 to 10.0 %/°C
    Compensation mode Linear or Pure Water
    Cell Constant K=0.1, 1, 10 or Custom
    Reference temperature 20 or 25°C
    Conductivity Mode
  • TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
    TDS Accuracy ± 1 % F.S.
    TDS Factor 0.1  to 1.0 (default 0.5)
    TDS Mode

Online Conductivity Controller LOCC-A10

  • 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cmConductivity measurement range
  • 1 to 3 pointsConductivity calibration points
  • ±1 % F.S.Conductivity accuracy
  • 0.001/ 0.01/ 0.1/ 1Conductivity resolution

Dissolved Oxygen Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket Dissolved oxygen tester LPKDO-A10

  • 0.0 to 20.0 mg/L (or ppm)Dissolved oxygen range
  • ± 0.5 mg/LDissolved oxygen accuracy
  • 0.0 to 200.0%% of saturation of oxygen
  • Polarographic dissolved oxygen probeSensor type

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Conductivity Meter LBCM-A13
  • 0.000 μS/cm to 3000mS/cmConductivity measurement range
  • 5.00 Ω·cm to 100.0 MΩ·cmResistivity measurement range
  • 0.000 mg/L to 1000g/LTDS measurement range
  • 0.00 to 8.00 %Salinity measurement range
Benchtop conductivity meter LBCM-A11
  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cmConductivity measurement range
  • ± 1 % F.S.Conductivity accuracy
  • 0.01, 0.1, 1Conductivity resolution
  • 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cmConductivity calibration solutions

Benchtop Conductivity Meter LBCM-A14

  • {"Conductivity measurement range":"0.01-20.0, 200.0, 2000 \u00b5S\/cm, 20.00, 200.0 mS\/cm","Conductivity accuracy":"\u00b11% F.S.","Conductivity resolution":"0.001, 0.01, 0.1, 1","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm , 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm"}Conductivity Mode
  • {"TDS measurement Range":"0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS Accuracy":"\u00b1 1 % F.S.","TDS Factor":"0.01 to 1.00 (default 0.5)","TDS Calibration points":"3 points"}TDS Mode
  • {"Temperature range":"0 to 105\u00b0C, 32 to 221\u00b0F","Temperature accuracy":"\u00b11\u00b0C","Temperature resolution":"0.1\u00b0C, 0.1\u00b0F","Temperature calibration points":"1 point","Temperature Compensation Range and Mode":"Manual or Automatic, 0 to 100\u00b0C , 32 to 212\u00b0F","Temperature coefficient":"0.0 to 10.0 % per \u00b0C"}Temperature Mode
  • K=0.1, 1, 10Cell constant