Portable water hardness meter LPWM-A10

Portable water hardness meter LPWM-A10 comes with LCD display, 2 to 5 points calibration system with low to high concentration range. It can measure salts of calcium, magnesium at mg/L, mmol/ scale. The calibration due reminder alerts user for calibration of the meter on regular basis. The System menu allows setting the 7 parameters like stability condition, auto-power off etc.

  • Water hardness range 0.05 mmol / L - 0.2 mol / L<br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Accuracy ± 1 % F.S.
    Calibration points 2 to 5 points
    Calibration solution 0.001, 0.01, 0.1 mmol / L, 0.001, 0.01, 0.1 mol / L
    Temperature compensation range 0 - 50 °C
    Compensation mode Manual or automatic
    Data hold function Manual or automatic endpoint detection
    Reset function Yes
    Stability condition Low or high
    Calibration due 0 to 31 days
    Memory Stores up to 500 sets of data
    Output USB communication interface
    Connector BNC
    Battery life Approximately 150 hours
    Power 3 × 1.5 V “AA” batteries
    Dimension (L × W × H) 170 × 85 × 30 mm
    Weight 300 g
    • Equipped with Large LCD display
    • 2 to 5 points calibration with low to high range
    • System menu with 7 parameters setting
    • Calibration due reminder for regular basis calibration of the meter
    • Stability indicator to automatically display current measurements
    • Manual temperature compensation for better measurement accuracy of meter
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Automatic temperature compensation for accurate measured value over the entire range
    • Reset function automatically resumes all the settings to default setting
    • Expanded memory can store up to 500 sets of data
    • Built-in real time clock stamps stored data to meet GLP standards
  • Portable water hardness meter is used in testing the hardness level of tap water, drinking water, filtered water, water used for different experiments and testing across food, textile, painting & other industries.

  • Water hardness electrode
    Temperature probe
    AA batteries
    Carrying case
  • Water hardness electrode range 0.00005 to 0.2 M

Portable Conductivity Meter LPCM-A12

  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Salinity range":"0.00 to 80.00 ppt, 0.00 to 42.00 psu","Salinity accuracy":"\u00b11% F.S","Salinity measurement modes":"Practical Salinity (psu) or Natural Seawater (ppt)","Salinity resolution":"0.01, 0.1, 1"}Salinity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation

Portable Conductivity Meter LPCM-A10

  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation
  • LinearTemperature coefficient
Portable Conductivity Meter LPCM-A11
  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"TDS range":"0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS accuracy":"\u00b11 % F.S","TDS factor":"0.01 to 1.00 (Default 0.5)","TDS resolution":"0.01, 0.1, 1"}TDS
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation

Dissolved Oxygen Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket Dissolved oxygen tester LPKDO-A10
  • 0.0 to 20.0 mg/L (or ppm)Dissolved oxygen range
  • ± 0.5 mg/LDissolved oxygen accuracy
  • 0.0 to 200.0%% of saturation of oxygen
  • Polarographic dissolved oxygen probeSensor type

Portable Turbidity Meter LTM-A11

  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume

Portable Turbidity Meter LTM-A10

  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume
Portable turbidity meter LTM-A16
  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11
  • 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cmConductivity measurement range
  • ± 1 % F.S.Conductivity accuracy
  • 0.01, 0.1, 1Conductivity resolution
  • 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cmConductivity calibration solutions

Benchtop Conductivity Meter LBCM-A14

  • {"Conductivity measurement range":"0.01-20.0, 200.0, 2000 \u00b5S\/cm, 20.00, 200.0 mS\/cm","Conductivity accuracy":"\u00b11% F.S.","Conductivity resolution":"0.001, 0.01, 0.1, 1","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm , 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm"}Conductivity Mode
  • {"TDS measurement Range":"0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS Accuracy":"\u00b1 1 % F.S.","TDS Factor":"0.01 to 1.00 (default 0.5)","TDS Calibration points":"3 points"}TDS Mode
  • {"Temperature range":"0 to 105\u00b0C, 32 to 221\u00b0F","Temperature accuracy":"\u00b11\u00b0C","Temperature resolution":"0.1\u00b0C, 0.1\u00b0F","Temperature calibration points":"1 point","Temperature Compensation Range and Mode":"Manual or Automatic, 0 to 100\u00b0C , 32 to 212\u00b0F","Temperature coefficient":"0.0 to 10.0 % per \u00b0C"}Temperature Mode
  • K=0.1, 1, 10Cell constant

Benchtop Conductivity Meter LBCM-A13

  • 0.000 μS/cm to 3000mS/cmConductivity measurement range
  • 5.00 Ω·cm to 100.0 MΩ·cmResistivity measurement range
  • 0.000 mg/L to 1000g/LTDS measurement range
  • 0.00 to 8.00 %Salinity measurement range

TDS Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket TDS tester LPTS-A12
  • 0.05 - 10.00 pptTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points
Pocket TDS tester LPTS-A11
  • 5 - 1000 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points

Pocket TDS tester LPTS-A10

  • 0.5 - 100.0 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points