Portable turbidity meter LTM-A16

Portable turbidity meter LTM-A16 is a device perceptively aimed with an LCD screen and an automatic power off function comprising of four AA batteries for ultimate usage. The instrument measures a range of 0.00-20.0; 20.01-200; 200.01-1000 NTU. This handy device also features an automatic range switchover that support zero-point and four-point calibration, coherent with ISO7027.The appearance being novel makes it expedient for users in field testing.

  • Light source LED/860 nm (Wavelength)
    Readings display LCD
    Unit switches NTU, FTU, EBC, ASBC
    Measurement range 0.00-20.0; 20.01-200; 200.01-1000 NTU
    Minimum reading 0.001
    Calibration modes 6
    Allowable error of indication ≤±6%
    Zero Drift ≤±0.5%FS
    Stability of indication ≤±0.5% FS
    Repeatability ≤0.5%
    Sample bottle Φ 25 mm×65 mm
    Sample volume 20-25 ml
    Interface USB
    Data storage 2000 sets
    Net Weight 650 gm
    • Implementing big-screen highly transparent LCD display, with comfortable readingbr
    • Entails a sample bottle measuring Φ 25 mm×65 mm
    • Offers a sample volume of 20-25 ml
    • Unique locative backlight set for transpiration
    • Subsidiary zero-point and four-point calibration for precisionism
    • Intended ISO7027 standard for quality presentation
    • Four AA batteries, external power supply, automatic power off function long lasting and effective use
    • Novel in appearance that makes convenient for users in field testing
    • Configured with automatic range switchover for prolong usage
  • Device is applicable for testing the turbidity of cloudiness in fluids caused by suspended solid particles in bacteriological and research laboratories, haziness in water, food beverages and other aqueous solutions.

Bench top Turbidity Meter (with built-in printer) LTM-C11

  • 0 to 100, 0 to 200, 0 to 500Measuring range (NTU)
  • 0.01Minimum readout value (NTU)
  • 3Calibration point
  • 18 to 20 mlSample volume

Portable Turbidity Meter LTM-A14

  • 0 to 100, 100 to 800Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 6Calibration point
  • 5 to 10 mlSample volume

Portable Turbidity Meter LTM-A15

  • 0 to 100, 100 to 1000Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 7Calibration point
  • 5 to 10 mlSample volume
Bench top Turbidity Meter LTM-B14
  • 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 6Calibration point
  • 5 to 10 mlSample volume
Bench top Turbidity Meter LTM-B11
  • 0 to 50, 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 3Calibration point
  • 5 to 10 mlSample volume

Portable Turbidity Meter LTM-A13

  • 0 to 100, 100 to 500Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 6Calibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter (with built-in printer) LTM-C14

  • 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000Measuring range (NTU)
  • 0.001Minimum readout value (NTU)
  • 5Calibration point
  • 18 to 20 mlSample volume

Bench top Turbidity Meter LTM-B12

  • 0 to 50, 0 to 100, 0 to 200, 0 to 400Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume
Bench top Turbidity Meter LTM-B10
  • 0 to 100Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 1Calibration point
  • 5 to 10 mlSample volume
Bench top Turbidity Meter (with built-in printer) LTM-C15
  • 0 to 10, 0 to 100Measuring range (NTU)
  • 0.001Minimum readout value (NTU)
  • 2Calibration point
  • 18 to 20 mlSample volume

Bench top Turbidity Meter (with built-in printer) LTM-C10

  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01Minimum readout value (NTU)
  • 2Calibration point
  • 18 to 20 mlSample volume

Bench top Turbidity Meter LTM-B13

  • 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 5Calibration point
  • 5 to 10 mlSample volume

Portable Turbidity Meter LTM-A10

  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume
Portable Turbidity Meter LTM-A11
  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume
Bench top Turbidity Meter (with built-in printer) LTM-C13
  • 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000Measuring range (NTU)
  • 0.01Minimum readout value (NTU)
  • 5Calibration point
  • 18 to 20 mlSample volume

Dissolved Oxygen Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket Dissolved oxygen tester LPKDO-A10

  • 0.0 to 20.0 mg/L (or ppm)Dissolved oxygen range
  • ± 0.5 mg/LDissolved oxygen accuracy
  • 0.0 to 200.0%% of saturation of oxygen
  • Polarographic dissolved oxygen probeSensor type

Water Activity Meter with sensor LWAM-A10

  • Water activity 0 to 0.980 aw (no condensing )Measuring range
  • 0 to 50°CTemperature range
  • ± 0.015 awMeasurement accuracy
  • ± 0.5°CTemperature accuracy
Water Activity Meter LWTM-A10
  • 0 to 1.0 awRange
  • 0 to 1.0 awResolution
  • ± 0.02 awAccuracy
  • Nonconductive humidity sensorSensor
Portable Chlorine Meter LPCL-A10
  • {"Range":"0.00 to 5.00 mg\/L","Accuracy":"0.001 mg\/L 0.001 ABS","Repeatability Lower detection limit":"\u22640.02 mg\/L"}Residual chlorine/total chlorine
  • {"Range":"0.00 to 10.00 mg\/L","Resolution":"0.001 mg\/L 0.001 ABS","Accuracy":"\u22642 mg\/L: \u00b10.10 mg\/L \u02c32 mg\/L: \u00b15 %","Lower detection limit":"\u22640.04 mg\/L"}Chlorine dioxide
  • LEDLight source
  • 515 nmWavelength of light

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for Cl, LBIM-A10

  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Na, LBIM-A12

  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for F, LBIM-A11
  • F range: 1 × 106M – saturation, 0.02 ppm to saturationIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
TSS Meter LTSS-A10
  • 20000 mg/L
    0.01 mg/L ~ 45000 mg/L
    0.01 mg/L ~ 120000 mg/L
    Measurement range
  • ± 2 % F.S. of its range ( Depending on the homogeneity of sludge)Measurement accuracy
  • ≤ 0.4 MpaPressure range
  • ≤ 2.5 m/s, 8.2 ft./sFlow rate