Bench top Turbidity Meter (with built-in printer) LTM-C15

Bench top turbidity meter (with built-in printer) LTM-C15 comes with microprocessor controlled system, works on 90° scattered light principle to measure water turbidity in nephelometric turbidity unit i.e. NTU. The formazine standard solution of turbidity mentioned in ISO 7027 is used for turbidity analysis. This turbidity meter delivers highly accurate results with better numerical calculations to meet GLP standards.

  • Measuring range (NTU) 0 to 10, 0 to 100
    Minimum readout value (NTU) 0.001
    Calibration point 2
    Sample volume 18 to 20 ml
    Principle method 90° scattered light
    Operating temperature Room Temperature
    Working temperature Room Temperature
    Light source Infrared-emitting diode (850 nm λ)
    Detector Silicon photodiode
    Error value (F.S) ±2%, ±3%,±5% 
    Zero drift (F.S) ±0.5% (0.02 NTU)
    Reset functions No
    Memory Nil
    Output RS232 data communication interface
    Dimension 415 × 375 × 200 mm
    Weight 4 kg
    Power batteries DC 1.5 V, 5 AA alkaline batteries
    Power supply AC 220 V, 50 Hz
    • Equipped with Built-in printer
    • Touch keypad backlight LCD display
    • Wide turbidity measurement range
    • High through put stability
    • Quick and automatic multi-points calibration
    • Auto power off function
    • Easy to operate
  • Used in water treatment plants, swimming pool, water recycling units, research and quality testing laboratories of pharmacy, life science, food, and beverage industry.

  • Accessory No. Name Quantity
    1 Specimen bottle 3 pcs
    2 400 NTU (Formazine) turbidity standard solution 1 bottle
    3 Power cable 1 pc

Portable Turbidity Meter LTM-A10

  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter LTM-B12

  • 0 to 50, 0 to 100, 0 to 200, 0 to 400Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter LTM-B10

  • 0 to 100Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 1Calibration point
  • 5 to 10 mlSample volume
Portable Turbidity Meter LTM-A15
  • 0 to 100, 100 to 1000Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 7Calibration point
  • 5 to 10 mlSample volume
Portable Turbidity Meter LTM-A14
  • 0 to 100, 100 to 800Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 6Calibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter (with built-in printer) LTM-C12

  • 0 to 10, 0 to 100, 0 to 200, 0 to 500Measuring range (NTU)
  • 0.001Minimum readout value (NTU)
  • 4Calibration point
  • 18 to 20 mlSample volume

Bench top Turbidity Meter (with built-in printer) LTM-C13

  • 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000Measuring range (NTU)
  • 0.01Minimum readout value (NTU)
  • 5Calibration point
  • 18 to 20 mlSample volume

Bench top Turbidity Meter LTM-B11

  • 0 to 50, 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 3Calibration point
  • 5 to 10 mlSample volume
Bench top Turbidity Meter (with built-in printer) LTM-C10
  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01Minimum readout value (NTU)
  • 2Calibration point
  • 18 to 20 mlSample volume
Portable turbidity meter LTM-A16
  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range

Portable Turbidity Meter LTM-A12

  • 0 to 100, 100 to 400Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 5Calibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter LTM-B13

  • 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 5Calibration point
  • 5 to 10 mlSample volume

Bench top Turbidity Meter (with built-in printer) LTM-C14

  • 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000Measuring range (NTU)
  • 0.001Minimum readout value (NTU)
  • 5Calibration point
  • 18 to 20 mlSample volume
Bench top Turbidity Meter (with built-in printer) LTM-C11
  • 0 to 100, 0 to 200, 0 to 500Measuring range (NTU)
  • 0.01Minimum readout value (NTU)
  • 3Calibration point
  • 18 to 20 mlSample volume
Portable Turbidity Meter LTM-A13
  • 0 to 100, 100 to 500Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 6Calibration point
  • 5 to 10 mlSample volume

TDS Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket TDS tester LPTS-A11

  • 5 - 1000 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points

Pocket TDS tester LPTS-A12

  • 0.05 - 10.00 pptTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points
Pocket TDS tester LPTS-A10
  • 0.5 - 100.0 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Multi-parameter Water Quality Meter LMPWM-A10
  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"0 to 19999 ppm, mg\/L, mol\/L","Ion accuracy":"\u00b1 0.5 % F.S. (monovalent), \u00b1 1 % F.S. (divalent)","Ion calibration points":"2 - 5 points","Ion calibration solutions":"0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol\/L, mg\/L"}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement

Portable Multi-parameter Water Quality Meter LMPWM-A20

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
  • {"TDS range":"0-100 ppt. (max. 200 ppt., depending on factor setting)","TDS accuracy":"\u00b1 1 % F.S.","TDS factor":"0.1 - 1.0 (default 0.5)"}TDS measurement

Portable Multi-parameter Water Quality Meter LMPWM-A11

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"","Ion accuracy":"","Ion calibration points":"","Ion calibration solutions":""}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for Na, LBIM-A12
  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for F, LBIM-A11
  • F range: 1 × 106M – saturation, 0.02 ppm to saturationIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Cl, LBIM-A10

  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Online Conductivity Controller LOCC-A10

  • 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cmConductivity measurement range
  • 1 to 3 pointsConductivity calibration points
  • ±1 % F.S.Conductivity accuracy
  • 0.001/ 0.01/ 0.1/ 1Conductivity resolution

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10
  • 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Water hardness range
  • ± 1 % F.S.Accuracy
  • 2 to 5 pointsCalibration points
  • 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/LCalibration solution