Online Dissolved Oxygen Controller LODC-A10

Online Dissolved Oxygen Controller LODC-A10 features 1 to 2 points dissolved oxygen calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. It measures the amount of dissolved oxygen in mg/l, ppm units or in % of saturation. The accuracy of measurement is improved by manual salinity and barometric pressure compensation mode.

  • Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
    Dissolved oxygen Calibration points 1 - 2 points
    Dissolved oxygen accuracy ± 0.5 mg / L
    Dissolved oxygen resolution 0.1 mg / L
    % of saturation of oxygen range 0.0 to 200.0 %
    % of saturation of oxygen accuracy ± 10 % F.S. ± 2.0%
    % of saturation of oxygen resolution 0.001
    Calibration solutions Saturated anhydrous sodium sulfite solution and air saturated water
    Temperature compensation range 0 to 40 °C, 32 °F to 104 °F
    Barometric pressure correction 60.0 to 112.5 kPa, 450 to 850 mmHg
    Salinity correction 0 - 35 g / L
    Signal output 4 to 20 mA
    Load Maximum 500 Ω
    Low and high alarm limits 1.00 to 18.00 mg/L (selectable)
    Connection Interface RS485
    Connection terminal Detectable screw terminals
    Display LCD screen
    Ambient Temperature <60°C
    Relative Humidity <80%
    Power supply DC 24 V
    Dimension (L x W x H) 96 × 96 × 75 mm
    Weight 350 g
    • Equipped with a polarographic electrode
    • Use of Zero oxygen solution, air saturated water for calibration
    • 1 to 2 dissolved oxygen calibration points
    • Controller with 4 multifunctional keys with names and symbols
    • ATC mode for accurate readings over entire range
    • Low and high alarm limits set automatically activate an external device
    • System menu allows setting up to 10 parameters
    • Reset features to resumes all setting back to default
  • Used in water treatment applications across waste water plants, filtration systems, RO treatment water plants, Agriculture, and Aquaculture industry.

  • Accessories no. Name Qty.
    1 DO Electrolyte solution ml 1 bottle
    2 Industrial dissolved oxygen probe 1
    3 DO Membrane cap 1

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

  • 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Water hardness range
  • ± 1 % F.S.Accuracy
  • 2 to 5 pointsCalibration points
  • 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/LCalibration solution

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Multi-parameter Water Quality Meter LMPWM-A10

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"0 to 19999 ppm, mg\/L, mol\/L","Ion accuracy":"\u00b1 0.5 % F.S. (monovalent), \u00b1 1 % F.S. (divalent)","Ion calibration points":"2 - 5 points","Ion calibration solutions":"0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol\/L, mg\/L"}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
Portable Multi-parameter Water Quality Meter LMPWM-A20
  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
  • {"TDS range":"0-100 ppt. (max. 200 ppt., depending on factor setting)","TDS accuracy":"\u00b1 1 % F.S.","TDS factor":"0.1 - 1.0 (default 0.5)"}TDS measurement
Portable Multi-parameter Water Quality Meter LMPWM-A11
  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"","Ion accuracy":"","Ion calibration points":"","Ion calibration solutions":""}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement

BOD Meter LBOD-A10

  • 0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
    0 to 4000 mg/ L (need to dilute) (subsection measurement)
    Determination range
  • Less or less than 10 %Measurement error
  • 1 to 6Sample container/ bottle quantity
  • 1000 mlSample container/ bottle Capacity

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop pH meter LBPM-A11

  • 0.00 to 14.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 2 pointsCalibration points
Benchtop pH Meter LBPM-B11
  • 0 to 100°C, 32°F to 212°F Manual or AutomaticTemperature compensation
  • Manual or automatic endpoint detectionHold function
  • Standard or High-accuracyStability criteria
  • 10, 30, 60 seconds, 10, 30 minutes or OffInterval readings
Benchtop pH meter LBPM-A20
  • -1.00 to 15.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 1-3 pointsCalibration points

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A11

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points

Benchtop Dissolved oxygen meter LBDO-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points