Pocket Conductivity tester LPCT-A12

Pocket Conductivity tester LPCT-A12 is equipped with platinum sensor & 1 point push button calibration system. The easy to use pocket conductivity meter comes with waterproof features design for protection against harsh conditions. Conductivity meter on the basis of its low, mid and high conductivity measurement range can be used for measuring conductivity of drinking water, waste water, brine water and liquids with high, low conductivity.

  • Conductivity measurement range 0.1 to 19.99 mS/cm
    Type of conductivity High range conductivity
    Conductivity accuracy ± 1 % F.S.
    Conductivity calibration points 1 point
    Conductivity calibration solutions 12.88 mS/cm
    Sensor type Platinum sensor
    Temperature compensation 0 °C - 50 °C
    Temperature coefficient 2 % per °C
    Cell constant K=1
    Normalization temperature 25 °C
    Data hold function Manual
    Display LCD screen
    Power off Manual or automatic (8 minutes after last key is pressed)
    Power 3 × 1.5 V “G134” batteries
    Battery life Approximately 150 hours
    Dimension (L*dia.) 185 × 40 mm
    Weight 100 g
    • Equipped with platinum sensor
    • High conductivity range
    • 1 point push button calibration to adjust the display value to known standard
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Automatic temperature compensation for accurate measured value over the entire range
    • Automatic power off helps to reduce battery power consumption
    • Waterproof features guarantees protection against harsh conditions
    • Replaceable electrode module to reduce the maintenance , replacement cost
  • Pocket Conductivity tester on the basis of its low, mid and high conductivity measurement range can be used for testing conductivity of pure water, drinking water , waste water, brine solutions and liquids.

  • 146.5 µS/cm, 1413 µS/cm, 12.88 mS/cm conductivity standard solutions
    G134 batteries
    Carrying box
  • 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm conductivity standard solutions
    Platinum conductivity electrode

Related Products of Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket Conductivity tester LPCT-A11

  • 10 to 1999 µS/cmConductivity measurement range
  • Mid-range conductivityType of conductivity
  • ± 1 % F.S.Conductivity accuracy
  • 1 pointConductivity calibration points

Pocket Conductivity tester LPCT-A10

  • 1.0 to 199.9 µS/cmConductivity measurement range
  • Low range conductivityType of conductivity
  • ± 1 % F.S.Conductivity accuracy
  • 1 pointConductivity calibration points

BOD Meter LBOD-A10

  • 0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
    0 to 4000 mg/ L (need to dilute) (subsection measurement)
    Determination range
  • Less or less than 10 %Measurement error
  • 1 to 6Sample container/ bottle quantity
  • 1000 mlSample container/ bottle Capacity

Portable Turbidity Meter LTM-A10

  • 0 to 200Measuring range (NTU)
  • 0.1Minimum readout value (NTU)
  • NilCalibration point
  • 5 to 10 mlSample volume
Portable turbidity meter LTM-A16
  • LED/860 nm (Wavelength)Light source
  • LCDReadings display
  • NTU, FTU, EBC, ASBCUnit switches
  • 0.00-20.0; 20.01-200; 200.01-1000 NTUMeasurement range
Portable Turbidity Meter LTM-A11
  • 0 to 100, 0 to 200Measuring range (NTU)
  • 0.01, 0.1Minimum readout value (NTU)
  • 4Calibration point
  • 5 to 10 mlSample volume

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

  • 0.05 mmol / L -0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Water hardness range
  • ± 1 % F.S.Accuracy
  • 2 to 5 pointsCalibration points
  • 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/LCalibration solution

Multi parameter water quality analyzer LMWA-A10

  • {"COD determination range":"2 to 10000 mg\/ L","COD measurement accuracy":"COD < 50 mg\/ L, \u2264 \u00b1 10 % \nand \nCOD > 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}COD
  • {"Ammonia nitrogen determination range":"0.02 to 60 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}Ammonia nitrogen
  • {"Total phosphorous determination range":"0.002 to 20 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}Total phosphorous
  • {"Turbidity determination range":"0.5 to 400 NTU","Turbidity measurement accuracy":"\u2264 \u00b1 5 %","Turbidity minimum detection limit":"0.1 NTU","Turbidity measurement time":"1 minute","Turbidity repeatability":"\u2264 \u00b1 5 %","Consumables for colorimetric turbidity measurement":"Colorimetric Cuvette"}Turbidity
Multi parameter water quality analyzer LMWA-A11
  • {"COD determination range":"5 to 5000 mg\/ L","COD measurement accuracy":"COD < 50 mg\/ L, \u2264 \u00b1 10 % \nand \nCOD > 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}COD
  • {"Ammonia nitrogen determination range":"0.02 to 30 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"20 pcs","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}Ammonia nitrogen
  • {"Total phosphorous determination range":"0.002 to 10 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}Total phosphorous
  • {"Turbidity determination range":"0.5 to 400 NTU","Turbidity measurement accuracy":"\u2264 \u00b1 5 %","Turbidity minimum detection limit":"0.1 NTU","Turbidity measurement time":"1 minute","Turbidity repeatability":"\u2264 \u00b1 5 %","Consumables for colorimetric turbidity measurement":"Colorimetric Cuvette"}Turbidity

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Dissolved oxygen meter LPRDO-A10
  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points

Portable dissolved oxygen meter LPRDO-A11

  • 0.0 - 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points