Benchtop Ion meter for Cd, LBIM-A28

Benchtop Ion meter for Cd, LBIM-A28 comes with (Cd) cadmium ion selective electrode for cadmium ion concentration measurement. This Ion meter comes with ± 1 % F.S. measurement accuracy. Its direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.

  • Ion measurement range Cd range: 1×10<sup>6</sup>– 1M, 0.01-11200 ppm
    Ion measurement accuracy ± 1 % F.S.
    Resolution 0.001, 0.01, 0.1, 1
    Calibration points 2 to 5 points
    Calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
    mV range (-1999.9) to 1999.9 mV
    mV accuracy ± 0.2 mV
    mV resolution 0.1 mV
    Temperature measurement range 0 to 105 °C, 32 to 221 °F
    Temperature accuracy ± 0.5 °C, ± 0.9 °F
    Temperature resolution 0.1°C
    Temperature compensation 0 to 100 °C, 32 to 212 °F
    Compensation mode Manual or automatic
    Data hold function Manual or automatic endpoint detection
    Reset function Yes
    Stability condition Low or high
    Calibration due 0 to 31 days
    Power off Manual or automatic (10,20,30 minutes)
    Memory Stores up to 500 sets of data
    Output USB communication interface
    Connector BNC
    Display LCD (130 × 110 mm)
    Power DC 5 V, using AC adapter, AC 220 V / 50 Hz
    Dimension (L × W × H) 210 × 188 × 60 mm
    Weight 1.5 kg
    • Large LCD display
    • 2 - 5 points calibration from low to high concentration
    • Direct ion concentration readout for elaborate measurement process
    • Selectable concentration units from ppm, mg / L, mol / L
    • mV measurements to check the performance of ion selective electrode
    • Temperature compensation provides accurate reading over the entire range
    • Stability indicator to show current measurement status
    • Calibration due reminder for regular calibration of the meter
    • Auto hold function to freeze stable reading for better viewing & recording
    • Automatic electrode diagnosis shows the slope of the sensor
    • Reset setting function
    • Expanded memory stores and recalls up to 500 readings
    • Built –in real time clock stamps
    • USB communication interface to transfer stored data to PC
  • Benchtop Ion meter is used to measure the cadmium ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.

  • Cd Ion selective electrode
    Temperature probe
    Standard solution (1000 ppm)
    Ionic strength adjuster (30 mL)
    USB cable
    DC 5 V Power adapter
  • Ion selective electrode: Cd range: 1×106– 1M, 0.01-11200 ppm
    Ion standard solutions: 480 mL / bottle
    Ionic strength adjuster: 480 mL / bottle
    Temperature probe with sensor

Related Products of Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for Cn, LBIM-A21

  • Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for K, LBIM-A23

  • K range: 1×106 - 1M, 0.04 -39000 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for NH<sub>4</sub>, LBIM-A15

  • NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Br, LBIM-A14
  • Br range: 5 × 106 - 1 M, 0.4 - 79900 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Pb, LBIM-A25
  • Pb range: 1×108 – 0.1M, 0.2-20700 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Ag, LBIM-A22

  • Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for F, LBIM-A11

  • F range: 1 × 106M – saturation, 0.02 ppm to saturationIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Ca, LBIM-A13

  • Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for NH<sub>3</sub> , LBIM-A20
  • NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Na, LBIM-A12
  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for I, LBIM-A26

  • I range: 1×108- 1M, 0.06 -127000 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Cu, LBIM-A27

  • Cu range: 1×108 - 1M, 0.06-6400 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for S, LBIM-A24

  • S range: 1×107 - 1M, 0.003-32100 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Cl, LBIM-A10
  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Online Conductivity Controller LOCC-A10

  • 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cmConductivity measurement range
  • 1 to 3 pointsConductivity calibration points
  • ±1 % F.S.Conductivity accuracy
  • 0.001/ 0.01/ 0.1/ 1Conductivity resolution

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Multi-parameter Water Quality Meter LMPWM-A20

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
  • {"TDS range":"0-100 ppt. (max. 200 ppt., depending on factor setting)","TDS accuracy":"\u00b1 1 % F.S.","TDS factor":"0.1 - 1.0 (default 0.5)"}TDS measurement
Portable Multi-parameter Water Quality Meter LMPWM-A10
  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"0 to 19999 ppm, mg\/L, mol\/L","Ion accuracy":"\u00b1 0.5 % F.S. (monovalent), \u00b1 1 % F.S. (divalent)","Ion calibration points":"2 - 5 points","Ion calibration solutions":"0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol\/L, mg\/L"}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
Portable Multi-parameter Water Quality Meter LMPWM-A11
  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"","Ion accuracy":"","Ion calibration points":"","Ion calibration solutions":""}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement

ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket ORP tester LPOT-A10

  • Platinum sensorSensor type
  • 6 pinConnector
  • (-999) to 999 mVORP measurement range
  • ± 2 mVORP accuracy

Pocket ORP tester LPOT-A11

  • BNCConnector
  • (-999) to 999 mVORP measurement range
  • ± 2 mVORP accuracy
  • 1 mVORP resolution
TSS Meter LTSS-A10
  • 20000 mg/L
    0.01 mg/L ~ 45000 mg/L
    0.01 mg/L ~ 120000 mg/L
    Measurement range
  • ± 2 % F.S. of its range ( Depending on the homogeneity of sludge)Measurement accuracy
  • ≤ 0.4 MpaPressure range
  • ≤ 2.5 m/s, 8.2 ft./sFlow rate

Portable Water Hardness Meters

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable water hardness meter LPWM-A10
  • 0.05 mmol / L - 0.2 mol / L
    (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
    (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
    Water hardness range
  • ± 1 % F.S.Accuracy
  • 2 to 5 pointsCalibration points
  • 0.001, 0.01, 0.1 mmol / L, 0.001, 0.01, 0.1 mol / LCalibration solution