Benchtop Ion meter for Cn, LBIM-A21

Benchtop Ion meter for Cn, LBIM-A21 comes with (Cn ) cyanide ion selective electrode for cyanide ion concentration measurement. This Ion meter comes with ± 1 % F.S. measurement accuracy. Its direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.

  • Ion measurement range Cn range: 5 × 10<sup>6</sup> – 0.01 M, 0.2 – 260 ppm
    Ion measurement accuracy ± 1 % F.S.
    Resolution 0.001, 0.01, 0.1, 1
    Calibration points 2 to 5 points
    Calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
    mV range (-1999.9) to 1999.9 mV
    mV accuracy ± 0.2 mV
    mV resolution 0.1 mV
    Temperature measurement range 0 to 105 °C, 32 to 221 °F
    Temperature accuracy ± 0.5 °C, ± 0.9 °F
    Temperature resolution 0.1°C
    Temperature compensation 0 to 100 °C, 32 to 212 °F
    Compensation mode Manual or automatic
    Data hold function Manual or automatic endpoint detection
    Reset function Yes
    Stability condition Low or high
    Calibration due 0 to 31 days
    Power off Manual or automatic (10,20,30 minutes)
    Memory Stores up to 500 sets of data
    Output USB communication interface
    Connector BNC
    Display LCD (130 × 110 mm)
    Power DC 5 V, using AC adapter, AC 220 V / 50 Hz
    Dimension (L × W × H) 210 × 188 × 60 mm
    Weight 1.5 kg
    • Large LCD display
    • 2 - 5 points calibration from low to high concentration
    • Direct ion concentration readout for elaborate measurement process
    • Selectable concentration units from ppm, mg / L, mol / L
    • mV measurements to check the performance of ion selective electrode
    • Temperature compensation provides accurate reading over the entire range
    • Stability indicator to show current measurement status
    • Calibration due reminder for regular calibration of the meter
    • Auto hold function to freeze stable reading for better viewing & recording
    • Automatic electrode diagnosis shows the slope of the sensor
    • Reset setting function
    • Expanded memory stores and recalls up to 500 readings
    • Built –in real time clock stamps
    • USB communication interface to transfer stored data to PC
  • Benchtop Ion meter is used to measure the cyanide ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.

  • Cn Ion selective electrode
    Temperature probe
    Standard solution (1000 ppm)
    Ionic strength adjuster (30 mL)
    USB cable
    DC 5 V Power adapter
  • Ion selective electrode: Cn range: 0.2 – 260 ppm
    Ion standard solutions: 480 mL / bottle
    Ionic strength adjuster: 480 mL / bottle
    Temperature probe with sensor

Related Products of Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for NH<sub>4</sub>, LBIM-A15

  • NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for I, LBIM-A26

  • I range: 1×108- 1M, 0.06 -127000 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Ag, LBIM-A22

  • Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Cl, LBIM-A10
  • Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Na, LBIM-A12
  • Na range: 1 × 105 - 1 M, 0.1 - 23000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for NH<sub>3</sub> , LBIM-A20

  • NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Cd, LBIM-A28

  • Cd range: 1×106– 1M, 0.01-11200 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Ca, LBIM-A13

  • Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for S, LBIM-A24
  • S range: 1×107 - 1M, 0.003-32100 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for Br, LBIM-A14
  • Br range: 5 × 106 - 1 M, 0.4 - 79900 ppmIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for F, LBIM-A11

  • F range: 1 × 106M – saturation, 0.02 ppm to saturationIon measurement range
  • ± 0.5 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Pb, LBIM-A25

  • Pb range: 1×108 – 0.1M, 0.2-20700 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Ion meter for Cu, LBIM-A27

  • Cu range: 1×108 - 1M, 0.06-6400 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points
Benchtop Ion meter for K, LBIM-A23
  • K range: 1×106 - 1M, 0.04 -39000 ppmIon measurement range
  • ± 1 % F.S.Ion measurement accuracy
  • 0.001, 0.01, 0.1, 1Resolution
  • 2 to 5 pointsCalibration points

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A10

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points

Benchtop Dissolved oxygen meter LBDO-A11

  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points
Portable Conductivity Meter LPCM-A12
  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Salinity range":"0.00 to 80.00 ppt, 0.00 to 42.00 psu","Salinity accuracy":"\u00b11% F.S","Salinity measurement modes":"Practical Salinity (psu) or Natural Seawater (ppt)","Salinity resolution":"0.01, 0.1, 1"}Salinity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation
Portable Conductivity Meter LPCM-A10
  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation
  • LinearTemperature coefficient

Portable Conductivity Meter LPCM-A11

  • {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 5 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}Conductivity
  • {"TDS range":"0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS accuracy":"\u00b11 % F.S","TDS factor":"0.01 to 1.00 (Default 0.5)","TDS resolution":"0.01, 0.1, 1"}TDS
  • {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}Temperature
  • 0 to 100 °C, 32 to 212 ° F, Manual or AutomaticTemperature compensation

Online pH Controller LOPC-A10

  • 01.00 to 15.00 pHpH measurement range
  • 1 to 3 pointspH calibration points
  • USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)pH Buffer Solutions
  • ± 0.01 pHpH accuracy

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Dissolved oxygen meter LPRDO-A10
  • 0.0 to 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.5 mg / LDissolved oxygen accuracy
  • 0.1 mg / LResolution
  • 1 - 2 pointsCalibration points
Portable dissolved oxygen meter LPRDO-A11
  • 0.0 - 20.0 mg / L (or ppm)Dissolved oxygen range
  • ± 0.2 mg / LDissolved oxygen accuracy
  • 0.01 mg / LResolution
  • 1 - 2 pointsCalibration points

Portable Chlorine Meter LPCL-A10

  • {"Range":"0.00 to 5.00 mg\/L","Accuracy":"0.001 mg\/L 0.001 ABS","Repeatability Lower detection limit":"\u22640.02 mg\/L"}Residual chlorine/total chlorine
  • {"Range":"0.00 to 10.00 mg\/L","Resolution":"0.001 mg\/L 0.001 ABS","Accuracy":"\u22642 mg\/L: \u00b10.10 mg\/L \u02c32 mg\/L: \u00b15 %","Lower detection limit":"\u22640.04 mg\/L"}Chlorine dioxide
  • LEDLight source
  • 515 nmWavelength of light