Water Purification System LWPS-C11

Water Purification System LWPS-C11 is top choice of high flux ultrapure water system from tap to ultrapure water, integrating pretreatment, RO and terminal filter into one. Its output ranges up to 90 liters/hour and offers flow rate up to 2 liters/minute (when tank is full). Features with tap water inlet, it can produce second stage RO water and EDI module, center EDI ultrapure water system. The 2nd stage RO water’s conductivity can stay 1 to 5 µs/cm, and the ultrapure water’s resistivity is more absolutely to 18.2 MΩ.cm. It completely meets the highest grades and offers ASTM standards. Designed with 7.0 inch touch LCD display, to detect the quality of 3 way water sensor, 2 way flow sensor ultrapure water. Equipped with Ultrafiltration module, effectively eliminate endotoxin and suitable for precise cell cultivating and IVF. It is auto self-flushing of RO membrane function, extend RO membrane life.

  • Output 2nd stage RO water 90 liters/hour
    Output ultrapure water Up to 2 liters/minute (when tank is full)
    Ultrapure Water Quality Resistivity (25°C) 18.2 M Ω cm<br/> TOC: < 3ppb<br/> Bacteria: <0.1 cfu/ml<br/> Particle (>0.2 µm): <1/ml<br/> Endotoxin: <0.001EU/ml<br/> RNases: <1pg/ml<br/> DNases: <5pg/ml
    EDI Resistivity >10.2 M Ω cm<br/> TOC: < 30ppb<br/> Silicone rejection rate: >99.9 %
    RO Water Quality Conductivity 1st stage RO water: Feed water Conductivity ×5 %<br/> Conductivity 2nd stage RO water: 1 to 5 µs/cm
    Feed water requirements Tap water, Temperature 5 to 45°C, Pressure 1.0 to 4.0 Kgf/cm2
    Dimension 610 × 585 × 1580 mm 
    Power Consumption 480 W
    Power Supply AC110 to 240 V, 50/60 Hz
    Weight about 75 kg
    Standard configuration Main body (Including 1 set of cartridge) +20 liters Pressure Tank and 20 liters pressure tank
    • Water Purification is unique and easy-to-install prefiltration pack system
    • Integrate with EDI module, without softener, chemical regeneration and replacing any DI cartridge
    • Self-maintenance of the reverse osmosis membrane
    • The system recirculates water when the system is not in use in order to maintain water quality
    • Built in 20 liters Pressure Tank and 20 liters plastic pressure water tank
    • Designed with graphic display clearly indicates all parameters
    • 3 doors and easy to replacing cartridge design, convenient to maintain system and replace cartridges
    • RO module with DOWs membrane, ensure long life, stable operation and high desalinization rate
    • Designed with multiple alarm function
    • Offers data storage and RS 232/USB communication port
    • Equipped with range of filters and cartridges are available for the system to match your water requirements of bacteria-free, pyrogen-free or nuclease-free
    • Ultrafiltration module, effectively eliminate endotoxin and suitable for precise cell cultivating and IVF
    • Easy to maintain and operate
  • Water Purification System is used in Molecular biology and life sciences, Animal cells and plant cell culture, Tissue culture, IVF, Electrophoresis, gel analysis, medium preparation etc. across Healthcare, Food & Beverage and Biochemistry microanalysis etc.

Water Purification System LWPS-A10

  • One stage (Type I)Water quality
  • RO water /Distilled water
    Water temperature: 5 ~ 40℃
    Feed water
  • 18.25 MΩ.cm @ 25 ℃Resistivity
  • < 5ppbTOC

Water Purification System LWPS-A11

  • Two stage(Type III and type I)Water quality
  • Tap waterTDS≤400ppm
    Water temperature: 5-40℃
    Type 3 water ≥10L/h
    Feed water
  • <5 μs/cm@25℃Conectivity
  • 18.25 MΩ.cm @ 25 ℃Resistivity

Water Purification System LWPS-C10

  • 90 liters/hourOutput 2nd stage RO water
  • Up to 2 liters/minute (when tank is full)Output ultrapure water
  • Resistivity (25°C) 18.2 M Ω cm
    TOC: < 3ppb
    Bacteria: <0.1 cfu/ml
    Particle (>0.2 µm): <1/ml
    Endotoxin: <0.001EU/ml
    RNases: <1pg/ml
    DNases: <5pg/ml
    Ultrapure Water Quality
  • Conductivity 1st stage RO water: Feed water Conductivity ×5 %
    Conductivity 2nd stage RO water: 1 to 5 µs/cm
    RO Water Quality

Type I and Type III Water Purification System

This water purification system is a combinational system that produces Type III water after RO and Type I water after deionization in one cycle

Type I and Type III RO Water Purification System LOTW-B11

  • ≥ 20 L / hr.Output of Pure water
  • Type I and Type IIIWater Type
  • 30 LWater Tank capacity
  • BenchtopConfiguration

Type I and Type III RO Water Purification System LOTW-B10

  • ≥ 10 L / hr.Output of Pure water
  • Type I and Type IIIWater Type
  • 30 LWater Tank capacity
  • BenchtopConfiguration
Type I and Type III RO Water Purification System LOTW-B12
  • ≥ 30 L / hr.Output of Pure water
  • Type I and Type IIIWater Type
  • 30 LWater Tank capacity
  • BenchtopConfiguration

UV Water Purification System

UV water purification systems destroy the DNA of micro-organisms making the water contamination free. Water produced from UV water purification is contamination free water which is potable for consumption

UV Water Purification System LUVW-B12
  • ≥ 30 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • BenchtopConfiguration
  • 30 LWater Tank capacity

UV Water Purification System LUVW-B10

  • ≥ 10 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • BenchtopConfiguration
  • 30 LWater Tank capacity

UV Water Purification System LUVW-B11

  • ≥ 20 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • BenchtopConfiguration
  • 30 LWater Tank capacity

Type II Water Purification System

This water purification system provides Type II level water with consistency and reliability. It removes approximately 98% of inorganic ions and 99 % of all dissolved organic substances

Type II Water Purification System LTWP-B11
  • ≥ 20 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • Type IIWater Type
  • 30 LWater Tank capacity
Type II Water Purification System LTWP-B10
  • ≥ 10 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • Type IIWater Type
  • 30 LWater Tank capacity

Type II Water Purification System LTWP-B12

  • ≥ 30 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • Type IIWater Type
  • 30 LWater Tank capacity

Type III Water Purification System

It provides Type III level water which is required for chemical and physical inspection or for washing lab glassware’s

Type III Water Purification System LHWP-B11

  • ≥ 20 L / hr.Output of Pure water
  • Type IIIWater Type
  • BenchtopConfiguration
  • Double Pass RO systemProcess
Type III Water Purification System LHWP-B12
  • ≥ 30 L / hr.Output of Pure water
  • Type IIIWater Type
  • BenchtopConfiguration
  • Double Pass RO systemProcess
Type III Water Purification System LHWP-B10
  • ≥ 10 L / hr.Output of Pure water
  • Type IIIWater Type
  • BenchtopConfiguration
  • Double Pass RO systemProcess

Deionized Water System LDIN-A10

  • 30 liters/hourOutput
  • Up to 2 liters/minute (with pressure tank)Flow rate
  • 2 reverse osmosis water, deionized waterPure water outlet
  • Resistivity: 16 to 18.2 M Ω cm
    Bacteria: N/A
    Particle (>0.1 µm): N/A
    Deionized Water Quality

Deionized Water System LDIN-A20

  • 30 liters/hourOutput
  • Up to 2 liters/minute (with pressure tank)Flow rate
  • 2 reverse osmosis water, deionized waterPure water outlet
  • Resistivity: 16 to 18.2 M Ω cm
    Bacteria: N/A
    Particle (>0.1 µm): N/A
    Deionized Water Quality