Water Purification System LWPS-A11

Water Purification System LWPS-A11 mainly consists of two stages of water quality and its feed water is tap water. It follows type III and type I systems. Features pretreatment system, RO system, ultrapure water system conveying unit and control system. Fully automatic control over the whole process, e.g. automatic water preparation, when water tank is full, automatically stop the system and cut off the power and water. Built-in RO membrane timing automatic flush procedures, and manual RO membrane cleaning button is available.

  • Water quality Two stage(Type III and type I)
    Feed water Tap waterTDS≤400ppm<hr> Water temperature: 5-40℃<hr> Type 3 water ≥10L/h
    Conectivity <5 μs/cm@25℃
    Resistivity 18.25 MΩ.cm @ 25 ℃
    TOC < 5ppb
    Bacteria < 0.1 cfu/ml
    Endotoxin < 0.001 EU/ml
    Particle ( > 0.22μm) <1/ml
    Absorbance (254nm,1cm optical distance) < 0.001 EU/ml
    Reactive Silica(SiO2) < 0.01 ppm
    RNases < 0.01 ng/ml
    DNases < 4 pg/μl
    Temperature 5 ℃ ~ 40 ℃
    Humidity 10 % ~ 80 %
    Water production rate Type 1 water flow rate: 1-1.5L/min
    Micro filtration Millipore Millipak 0.22μm membrane or hollowed fiber membrane filter
    Power supply 230 V/50 Hz 150 W
    Main body Dimension (L × W × H) 340 × 550 × 530 mm (bench type)
    • Millipore BioPak UF membrane to reduce the pyrogen, RNase, DNase
    • Ultra-purification system: Millipore ion exchange resin cartridge and special flow design, high ultra-purify efficiency
    • Effectively remove the trace ions in water; guarantee the stability of water quality
    • Micro filtration: Making the particles content (larger than 0.22μm) is <1/ml and bacteria less than 0.1CFU/ml
    • Built-in manual water cycling program and ultrapure water auto-cycle program to keep the water quality of ultrapure water
    • Water resistance on-line monitoring, realizing man-machine conversation
    • System can be installed on the lab bench
    • 30L PE water reservoir with vent valve
  • Used for Medical device injection to human body, DNA/RHA preparation, DNA testing, HPLC (test and analysis of amino acid, penicillin; Organic ingredients), GCMS, ICP, IC, gas chromatography, AAS etc.

Water Purification System LWPS-C11

  • 90 liters/hourOutput 2nd stage RO water
  • Up to 2 liters/minute (when tank is full)Output ultrapure water
  • Resistivity (25°C) 18.2 M Ω cm
    TOC: < 3ppb
    Bacteria: <0.1 cfu/ml
    Particle (>0.2 µm): <1/ml
    Endotoxin: <0.001EU/ml
    RNases: <1pg/ml
    DNases: <5pg/ml
    Ultrapure Water Quality
  • Resistivity >10.2 M Ω cm
    TOC: < 30ppb
    Silicone rejection rate: >99.9 %
    EDI

Water Purification System LWPS-A10

  • One stage (Type I)Water quality
  • RO water /Distilled water
    Water temperature: 5 ~ 40℃
    Feed water
  • 18.25 MΩ.cm @ 25 ℃Resistivity
  • < 5ppbTOC

Water Purification System LWPS-C10

  • 90 liters/hourOutput 2nd stage RO water
  • Up to 2 liters/minute (when tank is full)Output ultrapure water
  • Resistivity (25°C) 18.2 M Ω cm
    TOC: < 3ppb
    Bacteria: <0.1 cfu/ml
    Particle (>0.2 µm): <1/ml
    Endotoxin: <0.001EU/ml
    RNases: <1pg/ml
    DNases: <5pg/ml
    Ultrapure Water Quality
  • Conductivity 1st stage RO water: Feed water Conductivity ×5 %
    Conductivity 2nd stage RO water: 1 to 5 µs/cm
    RO Water Quality

Radio Frequency Identification Water Purification System

Radio Frequency Identification Water Purifier are equipped with a RFID Radio Frequency Identification Chip which helps keeping a check on the quality of water in real time. This helps in monitoring of parameters for the purifier

Radio Frequency Identification Water Purification System LRFW-B10

  • ≥ 10 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • BenchtopConfiguration
  • 30 LWater Tank capacity

Radio Frequency Identification Water Purification System LRFW-B11

  • ≥ 20 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • BenchtopConfiguration
  • 30 LWater Tank capacity
Radio Frequency Identification Water Purification System LRFW-B12
  • ≥ 30 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • BenchtopConfiguration
  • 30 LWater Tank capacity
Water Purification System LWPS-A10
  • One stage (Type I)Water quality
  • RO water /Distilled water
    Water temperature: 5 ~ 40℃
    Feed water
  • 18.25 MΩ.cm @ 25 ℃Resistivity
  • < 5ppbTOC

Water Purification System LWPS-C10

  • 90 liters/hourOutput 2nd stage RO water
  • Up to 2 liters/minute (when tank is full)Output ultrapure water
  • Resistivity (25°C) 18.2 M Ω cm
    TOC: < 3ppb
    Bacteria: <0.1 cfu/ml
    Particle (>0.2 µm): <1/ml
    Endotoxin: <0.001EU/ml
    RNases: <1pg/ml
    DNases: <5pg/ml
    Ultrapure Water Quality
  • Conductivity 1st stage RO water: Feed water Conductivity ×5 %
    Conductivity 2nd stage RO water: 1 to 5 µs/cm
    RO Water Quality

Water Purification System LWPS-A11

  • Two stage(Type III and type I)Water quality
  • Tap waterTDS≤400ppm
    Water temperature: 5-40℃
    Type 3 water ≥10L/h
    Feed water
  • <5 μs/cm@25℃Conectivity
  • 18.25 MΩ.cm @ 25 ℃Resistivity

UV Water Purification System

UV water purification systems destroy the DNA of micro-organisms making the water contamination free. Water produced from UV water purification is contamination free water which is potable for consumption

UV Water Purification System LUVW-B10
  • ≥ 10 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • BenchtopConfiguration
  • 30 LWater Tank capacity
UV Water Purification System LUVW-B12
  • ≥ 30 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • BenchtopConfiguration
  • 30 LWater Tank capacity

UV Water Purification System LUVW-B11

  • ≥ 20 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • BenchtopConfiguration
  • 30 LWater Tank capacity

Deionized Water System LDIN-A10

  • 30 liters/hourOutput
  • Up to 2 liters/minute (with pressure tank)Flow rate
  • 2 reverse osmosis water, deionized waterPure water outlet
  • Resistivity: 16 to 18.2 M Ω cm
    Bacteria: N/A
    Particle (>0.1 µm): N/A
    Deionized Water Quality
Deionized Water System LDIN-A20
  • 30 liters/hourOutput
  • Up to 2 liters/minute (with pressure tank)Flow rate
  • 2 reverse osmosis water, deionized waterPure water outlet
  • Resistivity: 16 to 18.2 M Ω cm
    Bacteria: N/A
    Particle (>0.1 µm): N/A
    Deionized Water Quality

Type II Water Purification System

This water purification system provides Type II level water with consistency and reliability. It removes approximately 98% of inorganic ions and 99 % of all dissolved organic substances

Type II Water Purification System LTWP-B10
  • ≥ 10 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • Type IIWater Type
  • 30 LWater Tank capacity

Type II Water Purification System LTWP-B12

  • ≥ 30 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • Type IIWater Type
  • 30 LWater Tank capacity

Type II Water Purification System LTWP-B11

  • ≥ 20 L / hr.Output of Pure water
  • Double Pass RO systemProcess
  • Type IIWater Type
  • 30 LWater Tank capacity