Benchtop pH meter LBPM-B10

Benchtop pH meter LBPM-B10 comes with -2.000 to 20.000 pH range and is suitable for daily pH measurement, testing. 1 to 5 points push button calibration is performed using standard USA or NIST pH buffers & 1 point calibration to measure ORP. It offers automatic or manual temperature compensation mode of pH measurements. The pH meter with sleek design has easy to read backlit LCD screen which shows pH measurements & temperature simultaneously.

  • pH measurement range -2.000 to 20.000 pH
    pH accuracy ± 0.002 pH
    pH resolution
    Calibration points 1-5 points
    Calibration solutions USA, NIST, DIN or user defined
    ORP measurement range -1999.9 to 1999.9 mV
    ORP accuracy ±0.2 mV
    ORP calibration points 1 point
    ORP calibration range ±200 mV
    ORP calibration solutions mV & relative mV
    Temperature compensation 0 to 100°C, 32 to 212°F
    Compensation mode Manual or automatic
    mV range
    mV accuracy
    mV resolution
    Temperature range
    Temperature accuracy
    Stability conditions Low or high
    Calibration due 0 to 31 days
    memory Stores up to 500 data sets
    Output USB communication interface
    Temperature resolution
    Hold function
    Power off
    Reset function
    Connector BNC
    Display LCD
    Dimension (L*W*H) 210×188×60 mm
    Weight 1.5 kg
    Power DC5V using AC adapter, AC220V /50 Hz
    • pH Mode Features:
    • Equipped with white backlit LCD display
    • pH measurement range -2.000 to 20.000 pH
    • 1 to 5 points push button calibration to automatically identify pH buffer
    • Automatic electrode slope display, helps the operator when to replace the sensor
    • Automatic temperature compensation for accurate measured value over the entire range
    • Universal BNC connector
    • Built-in solution holder
    • ORP Mode Features:
    • ORP measurement range -1999.9 to 1999.9 mV
    • Single point offset calibration to adjust the display value to a known standard
    • Relative & absolute mV measurements for accurate ORP readings
    • Common Features:
    • Calibration due reminder informs operator to calibrate the meter regularly
    • Stability indicator displays the status of current measurement
    • Auto hold function freezes stable, final readings for better viewing and recording
    • Manual temperature calibration to rectify the deviations in temperature
    • Automatic temperature compensation for accurate measured value over the entire range
    • Selectable temperature units (°C or °F) for different application requirements
    • Expanded memory stores and recalls up to 500 readings
    • Help message as an operational guide, helps users for quick access to the parameters
    • Reset function automatically resumes all the setting back to factory default options
    • Store data is transferrable into computer via USB communication interface
  • The benchtop pH meter can be used for daily measurement of pH, ORP & temperature at schools, colleges & research laboratories & water testing plants.

  • BNC pH Electrode
    Temperature probe
    pH buffer pouches (pH 4.01/7.00/10.01)
    USB cable
    Dc5V power adapter
  • pH Electrode
    pH buffer pouches (pH 4.01/6.98/9.18) NIST
    pH buffer pouches (pH 4.01/7.00/10.01) USA
    Temperature probe

Related Products of pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop pH Meter LBPM-B11

  • 0 to 100°C, 32°F to 212°F Manual or AutomaticTemperature compensation
  • Manual or automatic endpoint detectionHold function
  • Standard or High-accuracyStability criteria
  • 10, 30, 60 seconds, 10, 30 minutes or OffInterval readings

Benchtop pH meter LBPM-A20

  • -1.00 to 15.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 1-3 pointsCalibration points

Benchtop pH meter LBPM-A11

  • 0.00 to 14.00 pHpH measurement range
  • ± 0.01 pHpH accuracy
  • 0.01 pHpH resolution
  • 2 pointsCalibration points

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Portable Multi-parameter Water Quality Meter LMPWM-A20

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
  • {"TDS range":"0-100 ppt. (max. 200 ppt., depending on factor setting)","TDS accuracy":"\u00b1 1 % F.S.","TDS factor":"0.1 - 1.0 (default 0.5)"}TDS measurement

Portable Multi-parameter Water Quality Meter LMPWM-A10

  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"0 to 19999 ppm, mg\/L, mol\/L","Ion accuracy":"\u00b1 0.5 % F.S. (monovalent), \u00b1 1 % F.S. (divalent)","Ion calibration points":"2 - 5 points","Ion calibration solutions":"0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol\/L, mg\/L"}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
Portable Multi-parameter Water Quality Meter LMPWM-A11
  • {"pH measurement range":"(-2.000) to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH calibration points":"1 - 5 points","pH calibration solutions":"USA, NIST, DIN or user defined"}pH mode
  • {"ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration solutions":"mV & relative mV"}ORP measurement
  • {"Ion measurement range":"","Ion accuracy":"","Ion calibration points":"","Ion calibration solutions":""}Ion measurement
  • {"Conductivity measurement range":"0 - 20.00, 200.0, 2000 \u00b5S \/ cm, 20.00, 200.2 mS \/ cm","Conductivity accuracy":"\u00b1 0.5 % F.S.","Conductivity calibration points":"1 - 5 points","Conductivity calibration solutions":"10 \u00b5S \/ cm, 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88mS \/ cm, 111.8mS \/ cm","Temperature coefficient":"0.0 to 10.0 % \/ \u00b0C","Compensation modes":"Linear or pre water","Cell constant":"K = 0.1, 1, 10 or user-defined","Normalization temperature":"20 \u00b0C or 25 \u00b0C"}Conductivity measurement
BOD Meter LBOD-A10
  • 0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
    0 to 4000 mg/ L (need to dilute) (subsection measurement)
    Determination range
  • Less or less than 10 %Measurement error
  • 1 to 6Sample container/ bottle quantity
  • 1000 mlSample container/ bottle Capacity

TDS Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket TDS tester LPTS-A12

  • 0.05 - 10.00 pptTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points

Pocket TDS tester LPTS-A11

  • 5 - 1000 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points
Pocket TDS tester LPTS-A10
  • 0.5 - 100.0 ppmTDS range
  • ± 1 % F.S.TDS accuracy
  • 0.4 to 1.0 (default 0.5)TDS factor
  • 1 pointCalibration points
Portable Chlorine Meter LPCL-A10
  • {"Range":"0.00 to 5.00 mg\/L","Accuracy":"0.001 mg\/L 0.001 ABS","Repeatability Lower detection limit":"\u22640.02 mg\/L"}Residual chlorine/total chlorine
  • {"Range":"0.00 to 10.00 mg\/L","Resolution":"0.001 mg\/L 0.001 ABS","Accuracy":"\u22642 mg\/L: \u00b10.10 mg\/L \u02c32 mg\/L: \u00b15 %","Lower detection limit":"\u22640.04 mg\/L"}Chlorine dioxide
  • LEDLight source
  • 515 nmWavelength of light

Online pH Controller LOPC-A10

  • 01.00 to 15.00 pHpH measurement range
  • 1 to 3 pointspH calibration points
  • USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)pH Buffer Solutions
  • ± 0.01 pHpH accuracy