Rapid Low Temperature Circulating Bath LRTB-A20

Rapid Low Temperature Circulating Bath LRTB-A20 is a microcomputer controlled 5 L bath with refrigeration system and a temperature range of - 40 °C to 200 °C. Equipped with dual red and green LED windows with upper window measuring red value and lower measuring green value. Features internal and external cycles with external cycles discharging thermostatic liquid outside the bath raising the temperature of the external vessel.

  • Volume 5 L
    Temperature range - 40 °C to 200 °C
    Refrigerating capacity 1322 W
    Pump flow 20 L / min
    Temperature stability ± 0.1 °C
    Head of delivery 10 m
    Temperature control tier number 32
    Heating power 800 W
    • Volume - 5 L
    • Low temperature cooling pump
    • Microcomputer controlled temperature
    • Temperature and time LCD display
    • Built-in liquid level monitor
    • Refrigeration unit with relay , protector and capacitor
    • Anti-corrosive circulatory system

Rapid Low Temperature Circulating Bath LRTB-A11

  • 3 LVolume
  • - 10 °CTemperature range
  • 673 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A31

  • 7 LVolume
  • - 10 °CTemperature range
  • 1365 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A12

  • 3 LVolume
  • - 20 °CTemperature range
  • 782 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A30
  • 7 LVolume
  • - 5 °CTemperature range
  • 1122 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A40
  • 7 LVolume
  • - 40 °C to 200 °CTemperature range
  • 2329 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A71

  • 20 LVolume
  • - 20 °CTemperature range
  • 5008 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A73

  • 30 LVolume
  • - 40 °CTemperature range
  • 11808 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A51

  • 10 LVolume
  • - 10 °CTemperature range
  • 2458WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A32
  • 7 LVolume
  • - 20 °CTemperature range
  • 1538 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-B10
  • 13 LVolume
  • -50°C to 100°CTemperature Range
  • ± 0.2°CTemperature Stability
  • 8 L/ minPump Flow (flux)

Rapid Low Temperature Circulating Bath LRTB-A33

  • 7 LVolume
  • - 40 °CTemperature range
  • 2052 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A50

  • 10 LVolume
  • - 5 °CTemperature range
  • 2250 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A10

  • 3 LVolume
  • - 5 °CTemperature range
  • 500 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A70
  • 20 LVolume
  • - 10 °CTemperature range
  • 3960 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A52
  • 10 LVolume
  • - 20 °CTemperature range
  • 2651 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A12

  • 3 LVolume
  • - 20 °CTemperature range
  • 782 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A11

  • 3 LVolume
  • - 10 °CTemperature range
  • 673 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A10
  • 3 LVolume
  • - 5 °CTemperature range
  • 500 WRefrigerating capacity
  • 20 L / minPump flow
Water Bath LBC-A20
  • 34 LChamber volume
  • RT ( + 5 ℃ ~ 99 ℃ )Temperature range
  • ± 0.5 ℃Temperature stability
  • 1 ~ 999 minTiming range

Water bath LBC-A10

  • 11 LChamber volume
  • RT ( + 5 ℃ ~ 99 ℃ )Temperature range
  • ± 0.5 ℃Temperature stability
  • 1 ~ 999 minTiming range

High Temperature Oil Bath LHOB-A20

  • 20 LCapacity
  • RT to 300 °CTemperature range
  • ± 0.1 °CTemperature resolution
  • ± 0.1 °CTemperature fluctuation
High Temperature Oil Bath LHOB-A10
  • 15 LCapacity
  • 20 AElectric Leakage Switch
  • RT to 300℃Temperature Control Range
  • 0.1℃Temperature Resolution
High Temperature Oil Bath LHOB-A21
  • 20 LCapacity
  • RT to 300 °CTemperature range
  • ± 0.01 °CTemperature resolution
  • ± 0.05 °CTemperature fluctuation

Heating Circulating Bath LEMC-A20

  • 27 LChamber volume
  • RT ( + 5 ℃ ~ 70 ℃ )Temperature range
  • ± 0.3 ℃Temperature stability
  • 1 ~ 999 minTiming range

Heating Circulating Bath LEMC-A11

  • 30 LChamber volume
  • RT ( + 5 ℃ ~ 70 ℃ )Temperature range
  • ± 0.3 ℃Temperature stability
  • 1 ~ 999 minTiming range
Heating circulating bath LEMC-A10
  • 22 LChamber volume
  • RT ( + 5 ℃ ~ 70 ℃ )Temperature range
  • ± 0.3 ℃Temperature stability
  • 1 ~ 999 minTiming range
Thermostatic Water Bath LOTB-B12
  • 21 LCapacity
  • 6 holesHoles
  • 3Rows
  • Ф92 mmCover aperture

Thermostatic Water Bath LOTB-B11

  • 9 LCapacity
  • 4 holesHoles
  • 2Rows
  • Ф92 mmCover aperture

Thermostatic Water Bath LOTB-B10

  • 5 LCapacity
  • 2 holesHoles
  • 1Rows
  • Ф12 mmCover aperture