Rapid Low Temperature Circulating Bath LRTB-A51

Rapid Low Temperature Circulating Bath LRTB-A51 is a microcomputer controlled 10 L bath with cold ring liquid circulation and cryogenic liquid with a temperature range of -10 °C. Refrigeration unit with low temperature cooling pump facilitates consistent high pressure and maintenance of low temperature under working conditions of reaction experiments. Equipped with anti-corrosive circulatory system preventing traffic flow, high pressure and low pump body temperature.

  • Volume 10 L
    Temperature range - 10 °C
    Refrigerating capacity 2458W
    Pump flow 20 L / min
    Temperature stability ± 0.5 °C
    Head of delivery 10 m
    Temperature control tier number
    Heating power
    • Volume - 10 L
    • Low temperature cooling pump
    • Microcomputer controlled temperature
    • Temperature and time LCD display
    • Built-in liquid level monitor
    • Refrigeration unit with relay , protector and capacitor
    • Anti-corrosive circulatory system

Rapid Low Temperature Circulating Bath LRTB-A72

  • 20 LVolume
  • - 40 °CTemperature range
  • 7939 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A31

  • 7 LVolume
  • - 10 °CTemperature range
  • 1365 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A60

  • 10 LVolume
  • - 40 °C to 200 °CTemperature range
  • 3610 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A20
  • 5 LVolume
  • - 40 °C to 200 °CTemperature range
  • 1322 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A70
  • 20 LVolume
  • - 10 °CTemperature range
  • 3960 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A40

  • 7 LVolume
  • - 40 °C to 200 °CTemperature range
  • 2329 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A10

  • 3 LVolume
  • - 5 °CTemperature range
  • 500 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A12

  • 3 LVolume
  • - 20 °CTemperature range
  • 782 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A30
  • 7 LVolume
  • - 5 °CTemperature range
  • 1122 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A50
  • 10 LVolume
  • - 5 °CTemperature range
  • 2250 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A52

  • 10 LVolume
  • - 20 °CTemperature range
  • 2651 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A11

  • 3 LVolume
  • - 10 °CTemperature range
  • 673 WRefrigerating capacity
  • 20 L / minPump flow

Rapid Low Temperature Circulating Bath LRTB-A71

  • 20 LVolume
  • - 20 °CTemperature range
  • 5008 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A33
  • 7 LVolume
  • - 40 °CTemperature range
  • 2052 WRefrigerating capacity
  • 20 L / minPump flow
Rapid Low Temperature Circulating Bath LRTB-A73
  • 30 LVolume
  • - 40 °CTemperature range
  • 11808 WRefrigerating capacity
  • 20 L / minPump flow

Constant Temperature Water Bath LCTW-A10

  • 3.4 LInner chamber volume
  • RT +5°C to 100°CTemperature range
  • 0.1°CTemperature resolution
  • ±0.5°CTemperature motion

Constant Temperature Water Bath LCTW-A21

  • RT to 99.9°CTemperature range
  • 15 LChamber capacity
  • Ø 65 mm, 20 holesStructure
  • 0.01°CDisplay Precision
Constant Temperature Water Bath LCTW-A20
  • RT to 99.9°CTemperature range
  • 20 LChamber capacity
  • Ø 75 mm, 20 holesStructure
  • 0.01°CDisplay Precision
Heating Circulating Bath LEMC-A11
  • 30 LChamber volume
  • RT ( + 5 ℃ ~ 70 ℃ )Temperature range
  • ± 0.3 ℃Temperature stability
  • 1 ~ 999 minTiming range

Heating circulating bath LEMC-A10

  • 22 LChamber volume
  • RT ( + 5 ℃ ~ 70 ℃ )Temperature range
  • ± 0.3 ℃Temperature stability
  • 1 ~ 999 minTiming range

Heating Circulating Bath LEMC-A20

  • 27 LChamber volume
  • RT ( + 5 ℃ ~ 70 ℃ )Temperature range
  • ± 0.3 ℃Temperature stability
  • 1 ~ 999 minTiming range
Transparent Thermostatic Water Bath LTWB-A11
  • 8 LCapacity
  • RT to 100°CTemp. Range
  • 0.5°CTemp. Fluctuation
  • ≤ ± 1°CTemp. Accuracy
Transparent Thermostatic Water Bath LTWB-A10
  • 6 LCapacity
  • RT to 100°CTemp. Range
  • 0.5°CTemp. Fluctuation
  • ≤ ± 1°CTemp. Accuracy

Transparent Thermostatic Water Bath LTWB-A12

  • 20 LCapacity
  • RT to 100°CTemp. Range
  • 0.5°CTemp. Fluctuation
  • ≤ ± 1°CTemp. Accuracy

Water bath LBC-A10

  • 11 LChamber volume
  • RT ( + 5 ℃ ~ 99 ℃ )Temperature range
  • ± 0.5 ℃Temperature stability
  • 1 ~ 999 minTiming range
Water Bath LBC-A20
  • 34 LChamber volume
  • RT ( + 5 ℃ ~ 99 ℃ )Temperature range
  • ± 0.5 ℃Temperature stability
  • 1 ~ 999 minTiming range
Refrigerated Thermostatic Bath and Heating Circulators LRBC-A10
  • - 5 °C to 100 °CTemperature range
  • ± 0.05 °CTemperature stability
  • 260 x 200 x 140 mm3Tank size
  • 0 ~ 20 L / minPump flow

Refrigerated Thermostatic Bath and Heating Circulators LRBC-A12

  • - 10 °C to 100 °CTemperature range
  • ± 0.05 °CTemperature stability
  • 260 x 200 x 140 mm3Tank size
  • 0 ~ 20 L / minPump flow

Refrigerated Thermostatic Bath and Heating Circulators LRBC-A11

  • - 6 °C to 100 °CTemperature range
  • ± 0.05 °CTemperature stability
  • 260 x 200 x 140 mm3Tank size
  • 0 ~ 20 L / minPump flow