Horizontal Laboratory Autoclave LHA-A11

Horizontal Laboratory Autoclave LHA-A11 is a 500 L capacited top loading compact and robust high pressure steam sterilizing unit. The complete leak proof chamber provides efficient sterilization process resulting in destruction of all living organisms due to the high pressure and temperature maintained. It is equipped with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety.

  • Capacity 500 L
    Sterilization Temperature 134 °C
    Sterilization Pressure 0.22 Mpa
    Steam Pressure and the Consumption
    Water Source Pressure and the Consumption
    Timer Range 0 - 99 minutes
    Heat Average ≤ ± 1 ℃
    Dry Procedure
    Compressed Air Pressure
    Chamber Dimensions ( Φ × D )
    Product Dimension ( L × W × H ) 500 × 510 × 1010 mm
    Inner Chamber Dimension ( L × W × H )
    Outer Dimension ( L × W × H )
    Overall Size ( L × W × H ) 650 × 650 × 1200 mm
    Input Power
    Net Weight 375 kg
    Gross Weight 450 kg
    Power Supply 16 kW / AC 220 V 50 Hz
    • Digital LCD display to monitor working status and parameters
    • Working pressure : 0.22 MPa
    • Working temperature : 134 ℃
    • Automated drying function
    • Safe door lock system ensuring safety / protection during sterilization
    • Automatic power cut off with alarm with low water levels indication
    • Built in two pressure gages to indicate inner and interlayer pressure
  • It is suitable for medical, laboratory, microbiological, clinical use and to sterile the waste before discarding.

Related Products of Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-B11

  • 200 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 60 minutesTimer Range

Horizontal Laboratory Autoclave LHA-A10

  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-D16

  • 2000 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 55 kgSteam Pressure and the Consumption
Horizontal Autoclave LHA-I14
  • 180 LCapacity
  • 150°CDesign Temperature
  • 0.26 MPaDesign Pressure
  • 108 to 136°CSterilization Temperature Range
Horizontal Laboratory Autoclave LHA-F14
  • 1200 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 40 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-B10

  • 150 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 60 minutesTimer Range

Horizontal Laboratory Autoclave LHA-F11

  • 360 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 20 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-F12

  • 600 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 30 kgSteam Pressure and the Consumption
Horizontal Laboratory Autoclave LHA-B12
  • 280 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 60 minutesTimer Range
Horizontal Autoclave LHA-I12
  • 120 LCapacity
  • 150°CDesign Temperature
  • 0.26 MPaDesign Pressure
  • 107 to 136°CSterilization Temperature Range

Horizontal Laboratory Autoclave LHA-D11

  • 360 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 20 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-G11

  • 200 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 60 minutesTimer Range

Horizontal Autoclave LHA-I10

  • 60 LCapacity
  • 150°CDesign Temperature
  • 0.26 MPaDesign Pressure
  • 105 to 136°CSterilization Temperature Range
Horizontal Laboratory Autoclave LHA-F10
  • 250 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 15 kgSteam Pressure and the Consumption
Horizontal Laboratory Autoclave LHA-D15
  • 1500 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 50 kgSteam Pressure and the Consumption

Ethylene Oxide Sterilizer LEOS-A12

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 220 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A11

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 120 LCapacity
  • 50℃ ± 3℃Sterilization temperature
Ethylene Oxide Sterilizer LEOS-A10
  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 80 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-A11
  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-A10

  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal autoclave LHA-D18

  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure
Portable Autoclave LPOA-A11
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Portable Autoclave LPOA-A12
  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A13

  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Medical Autoclave

We offer Medical autoclave with user-friendly features which will not only sterilize the medical tools but can also be used for sterilizing medical waste prior to disposal with respect to the standards of municipal solid waste management.

Medical Autoclave LMA-A11

  • 17 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays
Medical Autoclave LMA-A10
  • 14 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays
Medical Autoclave LMA-A12
  • 23 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays

Plasma Autoclave LPA-A11

  • 120 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply

Plasma Autoclave LPA-A10

  • 80 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply
Plasma Autoclave LPA-A12
  • 240 LCapacity
  • Rectangular, double doorDoor type
  • Anti rust aluminum alloyChamber material