Horizontal Laboratory Autoclave LHA-B13

Horizontal Laboratory Autoclave LHA-B13 is a microprocessor controlled automatic autoclave.It has a capacity of 400 L and a maximum working temperature of 134 °C. Equipped with safety features like automatic shutoff preventing overload of current, auto protection against raised temperature and pressure making a reliable and user friendly device.

  • Capacity 400 L
    Sterilization Temperature 134 °C
    Sterilization Pressure 0.22 MPa
    Steam Pressure and the Consumption
    Water Source Pressure and the Consumption
    Timer Range 0 - 60 minutes
    Heat Average ≤ ± 1 ℃
    Dry Procedure
    Compressed Air Pressure
    Chamber Dimensions ( Φ × D ) 700 × 1100 mm
    Product Dimension ( L × W × H ) 1430 × 880 × 1830 mm
    Inner Chamber Dimension ( L × W × H )
    Outer Dimension ( L × W × H )
    Overall Size ( L × W × H )
    Input Power
    Net Weight 420 kg
    Gross Weight 530 kg
    Power Supply 18 kW / AC 380 V 50 Hz
    • Microprocessor control with fully automatic cycles
    • Digital LCD display to monitor working status and parameters
    • Working pressure : 0.22 MPa
    • Working temperature : 134 ℃
    • Automated drying function
    • Door lock feature : Door cannot be opened till the pressure inside the chamber doesn’t fall to 0.027 MPa
    • Safe door lock system ensuring safety / protection during sterilization
    • Automatic power cut off with alarm with low water levels indication
  • Horizontal autoclave with cylindrical shape is suitable for medical, laboratory, microbiological, clinical use and to sterile the waste before discarding.

Related Products of Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-F12

  • 600 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 30 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-F11

  • 360 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 20 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-A10

  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal Laboratory Autoclave LHA-F10
  • 250 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 15 kgSteam Pressure and the Consumption
Horizontal Laboratory Autoclave LHA-B10
  • 150 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 60 minutesTimer Range

Horizontal Laboratory Autoclave LHA-F14

  • 1200 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 40 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-F16

  • 2000 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 65 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-G12

  • 280 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0-60 minutesTimer Range
Horizontal Laboratory Autoclave LHA-D12
  • 600 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 30 kgSteam Pressure and the Consumption
Horizontal Laboratory Autoclave LHA-D10
  • 250 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 15 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-D13

  • 800 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 40 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-D16

  • 2000 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 55 kgSteam Pressure and the Consumption

Horizontal autoclave LHA-D18

  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure
Horizontal Laboratory Autoclave LHA-H10
  • 150 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal Laboratory Autoclave LHA-F15
  • 1500 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 55 kgSteam Pressure and the Consumption

Table Top

We deliver a wide range of Table Top autoclaves with user-friendly operating system and a capacity ranging from 20L to 50L. These are highly accurate, reliable and in compliance with Class N European Standards.

Tabletop Laboratory Autoclave LTTA-A11

  • 24 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure

Tabletop Laboratory Autoclave LTTA-A12

  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure
Tabletop Laboratory Autoclave LTTA-A13
  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure
Portable Autoclave LPOA-A11
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A12

  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A13

  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Ethylene Oxide Sterilizer LEOS-A10
  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 80 LCapacity
  • 50℃ ± 3℃Sterilization temperature
Ethylene Oxide Sterilizer LEOS-A11
  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 120 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A12

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 220 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-A11

  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal autoclave LHA-D18
  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure
Horizontal Laboratory Autoclave LHA-A10
  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-C11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-C10

  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 318 × 450 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C12
  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )