Horizontal Laboratory Autoclave LHA-F12

Horizontal Laboratory autoclave LHA-F12 is a 600 L capacited pulse vacuum single door autoclave. With a maximum working temperature of 134 °C it effectively sterilizes media, liquids and waste to be discarded. High quality insulation and air sealed structure makes it efficient for large scale sterilization. Equipped with safety features like automatic shutoff preventing overload of current, auto protection against raised temperature and pressure making a reliable and user friendly device.

  • Capacity 600 L
    Sterilization Temperature 139 °C
    Sterilization Pressure 0.25MPa
    Steam Pressure and the Consumption 0.4 - 0.6 MPa / 30 kg
    Water Source Pressure and the Consumption 0.2 to 0.3 MPa / 200 kgs
    Timer Range
    Heat Average
    Dry Procedure
    Compressed Air Pressure 0.6 - 0.8 MPa
    Chamber Dimensions ( Φ × D )
    Product Dimension ( L × W × H )
    Inner Chamber Dimension ( L × W × H ) 1200 × 610 × 910 mm
    Outer Dimension ( L × W × H ) 1500 × 1350 × 1950 mm
    Overall Size ( L × W × H )
    Input Power
    Net Weight 1100 kg
    Gross Weight
    Power Supply 36 kW
    • Digital LCD display to monitor working status and parameters
    • Working pressure : 0.22 MPa
    • Working temperature : 134 ℃
    • Door lock feature : Door cannot be opened till the pressure inside the chamber doesn’t fall to 0.027 MPa
    • Self-inflating leak proof chamber
    • Safe door lock system ensuring safety / protection during sterilization
    • Automatic power cut off with alarm with low water levels indication
  • Horizontal autoclave is widely used in pharmaceuticals, medical & clinical research laboratories, and life science industry to sterile material to be used and also to sterile the waste before discarding

Related Products of Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-H11

  • 200 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-H12

  • 280 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-B12

  • 280 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 60 minutesTimer Range
Horizontal Laboratory Autoclave LHA-D13
  • 800 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 40 kgSteam Pressure and the Consumption
Horizontal autoclave LHA-D18
  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure

Horizontal Laboratory Autoclave LHA-F13

  • 800 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 40 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-D11

  • 360 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 20 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-B10

  • 150 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 60 minutesTimer Range
Horizontal Laboratory Autoclave LHA-A11
  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal Laboratory Autoclave LHA-H10
  • 150 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-D10

  • 250 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 15 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-G12

  • 280 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0-60 minutesTimer Range

Horizontal Laboratory Autoclave LHA-E11

  • 200 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal Laboratory Autoclave LHA-F16
  • 2000 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 65 kgSteam Pressure and the Consumption
Horizontal Autoclave LHA-I10
  • 60 LCapacity
  • 150°CDesign Temperature
  • 0.26 MPaDesign Pressure
  • 105 to 136°CSterilization Temperature Range

Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-A10

  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-A11

  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal autoclave LHA-D18
  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure
Ethylene Oxide Sterilizer LEOS-A10
  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 80 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A12

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 220 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A11

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 120 LCapacity
  • 50℃ ± 3℃Sterilization temperature
Portable Autoclave LPOA-A12
  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Portable Autoclave LPOA-A11
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A13

  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Table Top

We deliver a wide range of Table Top autoclaves with user-friendly operating system and a capacity ranging from 20L to 50L. These are highly accurate, reliable and in compliance with Class N European Standards.

Tabletop Laboratory Autoclave LTTA-A13

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure
Tabletop Laboratory Autoclave LTTA-A12
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure
Tabletop Laboratory Autoclave LTTA-A11
  • 24 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure

Medical Autoclave

We offer Medical autoclave with user-friendly features which will not only sterilize the medical tools but can also be used for sterilizing medical waste prior to disposal with respect to the standards of municipal solid waste management.

Medical Autoclave LMA-A11

  • 17 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays

Medical Autoclave LMA-A10

  • 14 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays
Medical Autoclave LMA-A12
  • 23 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays