Horizontal Laboratory Autoclave LHA-B12

Horizontal Laboratory Autoclave LHA-B12 is a microprocessor controlled automatic autoclave.It has a capacity of 280 L and a maximum working temperature of 134 °C. Equipped with safety features like automatic shutoff preventing overload of current, auto protection against raised temperature and pressure making a reliable and user friendly device.

  • Capacity 280 L
    Sterilization Temperature 134 °C
    Sterilization Pressure 0.22 MPa
    Steam Pressure and the Consumption
    Water Source Pressure and the Consumption
    Timer Range 0 - 60 minutes
    Heat Average ≤ ± 1 ℃
    Dry Procedure
    Compressed Air Pressure
    Chamber Dimensions ( Φ × D ) 600 × 1000 mm
    Product Dimension ( L × W × H ) 1400 × 770 × 1780 mm
    Inner Chamber Dimension ( L × W × H )
    Outer Dimension ( L × W × H )
    Overall Size ( L × W × H )
    Input Power
    Net Weight 365 kg
    Gross Weight 465kg
    Power Supply 12 kW / AC 380 V 50 Hz
    • Microprocessor control with fully automatic cycles
    • Digital LCD display to monitor working status and parameters
    • Working pressure : 0.22 MPa
    • Working temperature : 134 ℃
    • Automated drying function
    • Door lock feature : Door cannot be opened till the pressure inside the chamber doesn’t fall to 0.027 MPa
    • Safe door lock system ensuring safety / protection during sterilization
    • Automatic power cut off with alarm with low water levels indication
  • Horizontal autoclave with cylindrical shape is suitable for medical, laboratory, microbiological, clinical use and to sterile the waste before discarding.

Related Products of Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-H11

  • 200 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-B10

  • 150 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 60 minutesTimer Range

Horizontal Laboratory Autoclave LHA-G12

  • 280 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0-60 minutesTimer Range
Horizontal Laboratory Autoclave LHA-G10
  • 150 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 60 minutesTimer Range
Horizontal autoclave LHA-D18
  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure

Horizontal Autoclave LHA-I14

  • 180 LCapacity
  • 150°CDesign Temperature
  • 0.26 MPaDesign Pressure
  • 108 to 136°CSterilization Temperature Range

Horizontal Laboratory Autoclave LHA-H12

  • 280 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-F10

  • 250 LCapacity
  • 139 °CSterilization Temperature
  • 0.25MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 15 kgSteam Pressure and the Consumption
Horizontal Laboratory Autoclave LHA-D10
  • 250 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 15 kgSteam Pressure and the Consumption
Horizontal Laboratory Autoclave LHA-B14
  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 60 minutesTimer Range

Horizontal Laboratory Autoclave LHA-G11

  • 200 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 60 minutesTimer Range

Horizontal Laboratory Autoclave LHA-D12

  • 600 LCapacity
  • 139 °CSterilization Temperature
  • 0.22MPaSterilization Pressure
  • 0.4 - 0.6 MPa / 30 kgSteam Pressure and the Consumption

Horizontal Laboratory Autoclave LHA-E12

  • 280 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal Autoclave LHA-I12
  • 120 LCapacity
  • 150°CDesign Temperature
  • 0.26 MPaDesign Pressure
  • 107 to 136°CSterilization Temperature Range
Horizontal Laboratory Autoclave LHA-B11
  • 200 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 0 - 60 minutesTimer Range

Plasma Autoclave LPA-A12

  • 240 LCapacity
  • Rectangular, double doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply

Plasma Autoclave LPA-A10

  • 80 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply
Plasma Autoclave LPA-A11
  • 120 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply
Ethylene Oxide Sterilizer LEOS-A11
  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 120 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A12

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 220 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A10

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 80 LCapacity
  • 50℃ ± 3℃Sterilization temperature
Portable Autoclave LPOA-A11
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Portable Autoclave LPOA-A13
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A12

  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-C11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C12
  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C10
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 318 × 450 mmChamber Dimension ( Φ × D )

Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-A10

  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-A11

  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal autoclave LHA-D18
  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure