Viscometer LVM-D10

Viscometer LVM-D10 is adopted with advanced micro-processor based technology to control speed, test operations, data collection and interpretation. The highly sensitive viscometer comes with 25 mPa.s to 1×10000000 mPa.s measurement range, is easy to operate and provides accurate, reliable results. Equipped with white backlight LCD display enables user to view viscosity test parameters like no. of samples, rotors specification, speed & other important information.

  • Measurement range 25 mPa.s to 1×10000000 mPa.s
    Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
    Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
    Temperature control range 45 to 200°C
    Temperature control accuracy ± 0.1°C
    Sample cylinder 20 ml
    Measurement error
    Measurement mode Automatic
    Print output Thermal printer
    Connection to PC RS232 interface
    Power supply AC 220V ± 10%, 50 Hz
    Relative humidity ≤ 80%
    Ambient temperature 5 to 35°C
    Dimension 460 × 410 × 450 mm
    Gross weight 14 kg
    HS Code 90278099
    • Equivalent to Brookfield Viscometer
    • Different rotors selection as per test requirement
    • 11 grades of rotational speed
    • Measurement range 25 mPa.s to 1×10000000 mPa.s
    • Equipped with Thermal printer
    • Connection to PC via RS232 interface
    • Easy to operate
  • Used to determine viscosities of asphalt, paraffin, high polymer, pharmaceutical drugs & other liquids in paint & oil industry, pharmaceuticals, food & beverage industry, high polymer and other industries.

  • Accessories No Name
    1 Water Bath
    2 Rotor No. 30
    3 300°C heating furnace
    4 Standard viscosity oil- 200 ml
    5 Rotor No. 21, 27, 28, 29
    6 Rotor No. 0

Viscometer LVM-B10

  • 0.1 to 100,000 mPa.sMeasuring range
  • 6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)

Viscometer LVM-A40

  • 3 to 1600000 M (mPa.s)Viscosity Range
  • 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpmRotation speed range
  • 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 mlSpindles
  • 18#,25#,31#,34# (standard configuration)Rotor

Viscometer LVM-B11

  • 0.1 to 2,000,000 mPa.sMeasuring range
  • 0.3/0.6/1.5/3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)
Viscometer LVM-D11
  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range
Viscometer LVM-A23
  • HB: 800 to 104000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0 % (of full range)Accuracy

Viscometer LVM-C12

  • 1 to 200000 mPa.sMeasuring range
  • 0.3/0.6/1.5/3.6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)

Viscometer LVM-A41

  • 0.3 to 100 rpmRotational speed range
  • Rotor R2 to R7 (6, Standard), R1 (Apolegamy)Standard Rotor
  • Rotor R2 to R7:100 to 4000 M (mPa.s)Viscosity measurement range
  • Rotor R1 to R7: 500 mlStandard Rotor Sample Dosage

Viscometer LVM-C10

  • 1 to 100000 mPa.sMeasuring range
  • 3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)
Viscometer LVM-D20
  • 40.2 KU to 141.0 KU
    32 g to 1099 g
    27 to 5250 CP
    Viscosity Range
  • 200±0.1 rpmRotation speed range
  • ± 3 %Accuracy
  • ±1.5 %Repeatability
Viscometer LVM-C11
  • 1 to 100000 mPa.sMeasuring range
  • 3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±0.5%Measuring Error (Newtonian liquid)

Viscometer LVM-D12

  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-A21

  • RV: 100 to 13000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0 % (of full range)Accuracy

Viscometer LVM-A20

  • LV: 1 to 2000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • LV: (1#, 2#, 3#, 4# spindles) (0# is optional)Spindles
  • ± 1.0 % (of full range)Accuracy
Viscometer LVM-A31
  • RV: 100 to 40000000 mPa.sViscosity Range
  • 0.1 to 250 rpmRotation speed range
  • (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0% (of full range)Accuracy
Viscometer LVM-A10
  • 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cPMeasuring range
  • 0.1 - 200 rpmRotating speed
  • ± 1.0 % full rangeMeasuring Error (Newtonian liquid)
  • ± 0.5 %Repeatability error (Newtonian liquid))

Cone Plate Viscometer LCPV-A10

  • ± 2 % (F.S)Accuracy
  • -1℃ to 150℃ (± 0.1℃)Temperature
  • Spindle No CAP-01 CAP-04
    Shear Rate 13.3 N 3.3 N
    Sample Volume 67µL 134µL
    LCPV-A10 (400rpm) 47-469 300-3,750
    LCPV-A10 (750rpm) 25-250 200-2,000
    LCPV-A10 (900rpm) 20-208 170-1,667
    Spindle Details
  • rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.sNote

Viscometer LVM-D12

  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range
Viscometer LVM-D11
  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range
Viscometer LVM-D10
  • 25 mPa.s to 1×10000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/minRotor speed
  • 45 to 200°CTemperature control range

Ubbelohde Viscometer LUV-A10

  • 0.3 - 50000 mm2/sMeasuring range
  • 2Measure position
  • 25 LBath volume
  • 0.01 sTiming accuracy

Ubbelohde Viscometer LUV-A12

  • 0.3 - 50000 mm2/sMeasuring range
  • 6Measure position
  • 41 LBath volume
  • 0.01 sTiming accuracy
Ubbelohde Viscometer LUV-A11
  • 0.3 - 50000 mm2/sMeasuring range
  • 4Measure position
  • 33 LBath volume
  • 0.01 sTiming accuracy