Ubbelohde Viscometer LUV-A10

Ubbelohde Viscometer LUV-A10 has LCD display screen to show the running status of each measurement unit, precisely 6 units at the same time. It has 2 measuring positions & it can obtain intrinsic viscosity through one point method. There is no need to monitor the process after the start in this viscometer, the auto test runs continuously until the test gets completed. It accurately controls the temperature, time & flow rate of fluid tested. It meets FDA & GLP regulations on experiment data management.

  • Measuring range 0.3 - 50000 mm<sup>2</sup>/s
    Measure position 2
    Bath volume 25 L
    Timing accuracy 0.01 s
    Temperature range 5 °C - 95 °C
    Temperature fluctuation & uniformity ± 0.01 °C
    Temperature accuracy Better than ± 0.01 °C
    Water bath Inner dimension 540 × 170 × 320 mm
    Water bath Outer dimension 610 × 270 × 500 mm
    Heating power 1 kW, 220 V
    Material applicable PET, PS, SAN, PBT, PMMA, PCT, PA, PIB, TPU, PAM, PSU, PEN, PC, PLA,CA, PVC, SB, Chitin, PAN, TP etc.
    • Display screen controls 6 units at the same time
    • One point method / single concentration method
    • Composed of Stainless steel material
    • Automatic cleaning instead of manual cleaning
    • No need to disassemble ubbelohde viscometer to avoid manmade damage
    • All viscosity formulas present in the system, testing personnel can use them conveniently
    • Data statistics function
    • Provision of basic data for controlling quality of the products
    • Can obtain intrinsic viscosity through one point method
  • Ubbelohde viscometer helps in obtaining kinetic viscosity, Dynamic viscosity, Relative viscosity, Viscosity ratio, DP, intrinsic viscosity & average molecular weight of chemical fluids, polymers and biological fluids.

  • Viscometer tube washer

Ubbelohde Viscometer LUV-A12

  • 0.3 - 50000 mm2/sMeasuring range
  • 6Measure position
  • 41 LBath volume
  • 0.01 sTiming accuracy

Ubbelohde Viscometer LUV-A11

  • 0.3 - 50000 mm2/sMeasuring range
  • 4Measure position
  • 33 LBath volume
  • 0.01 sTiming accuracy

Automatic (high temperature) Ubbelohde Viscometer LUV-B20

  • 1Measure position
  • PolydimethylsiloxaneOil bath medium
  • 10 °C to 180 °COil bath temperature range
  • 8 LBath volume
Automatic Ubbelohde viscometer LUV-B10
  • 0.35 to 5000 mm2/sMeasuring range
  • 2 (4 units measuring position at option)Measure position
  • 12 LBath volume
  • 0.01 sTiming accuracy

Ubbelohde Viscometer LUV-A11

  • 0.3 - 50000 mm2/sMeasuring range
  • 4Measure position
  • 33 LBath volume
  • 0.01 sTiming accuracy

Ubbelohde Viscometer LUV-A12

  • 0.3 - 50000 mm2/sMeasuring range
  • 6Measure position
  • 41 LBath volume
  • 0.01 sTiming accuracy
Ubbelohde Viscometer LUV-A10
  • 0.3 - 50000 mm2/sMeasuring range
  • 2Measure position
  • 25 LBath volume
  • 0.01 sTiming accuracy
Cone Plate Viscometer LCPV-A10
  • ± 2 % (F.S)Accuracy
  • -1℃ to 150℃ (± 0.1℃)Temperature
  • Spindle No CAP-01 CAP-04
    Shear Rate 13.3 N 3.3 N
    Sample Volume 67µL 134µL
    LCPV-A10 (400rpm) 47-469 300-3,750
    LCPV-A10 (750rpm) 25-250 200-2,000
    LCPV-A10 (900rpm) 20-208 170-1,667
    Spindle Details
  • rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.sNote

Viscometer LVM-D11

  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range

Viscometer LVM-D12

  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range
Viscometer LVM-D10
  • 25 mPa.s to 1×10000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/minRotor speed
  • 45 to 200°CTemperature control range