Automatic Ubbelohde viscometer LUV-B10

Automatic ubbelohde viscometer LUV-B10 with high temperature has 180°C heated oil design, measures viscosity of polymers with high temperature and it has 2 units for measurement. This viscometer is complied in accordance with ISO, ASTM, DIN standards. In this model everything from cleaning the capillary tube to testing is done automatically.

  • Measuring range 0.35 to 5000 mm<sup>2</sup>/s
    Measure position 2 (4 units measuring position at option)
    Oil bath medium
    Oil bath temperature range
    Bath volume 12 L
    Bath power
    Timing accuracy 0.01 s
    Temperature accuracy Better than ± 0.01 °C
    Sample tray
    Temperature range 5 °C - 95 °C
    Heating power 1 kW,220 V
    Dimension (L × W × H) 660 × 320 × 680 mm
    Material available PET, PS, SAN, PBT, PMMA, PCT, PA, PIB, TPU, PAM, PSU, PEN, PC, PLA,CA, PVC, SB, Chitin, PAN, TP etc.
    • 2 Measurement unit
    • Composed of stainless steel material
    • Polymer viscosity testing
    • Automatic injection
    • Provision of on line automatic cleaning instead of manual cleaning
    • Less reagent consumption
    • No need to disassemble ubbelohde viscometer to avoid manmade damage
  • This ubbelohde viscometer is designed for viscosity testing of high temperature (kinetic viscosity, Dynamic viscosity, Relative viscosity) polymers.

Ubbelohde Viscometer LUV-A11

  • 0.3 - 50000 mm2/sMeasuring range
  • 4Measure position
  • 33 LBath volume
  • 0.01 sTiming accuracy

Ubbelohde Viscometer LUV-A10

  • 0.3 - 50000 mm2/sMeasuring range
  • 2Measure position
  • 25 LBath volume
  • 0.01 sTiming accuracy

Ubbelohde Viscometer LUV-A12

  • 0.3 - 50000 mm2/sMeasuring range
  • 6Measure position
  • 41 LBath volume
  • 0.01 sTiming accuracy
Automatic (high temperature) Ubbelohde Viscometer LUV-B20
  • 1Measure position
  • PolydimethylsiloxaneOil bath medium
  • 10 °C to 180 °COil bath temperature range
  • 8 LBath volume

Ubbelohde Viscometer LUV-A11

  • 0.3 - 50000 mm2/sMeasuring range
  • 4Measure position
  • 33 LBath volume
  • 0.01 sTiming accuracy

Ubbelohde Viscometer LUV-A10

  • 0.3 - 50000 mm2/sMeasuring range
  • 2Measure position
  • 25 LBath volume
  • 0.01 sTiming accuracy
Ubbelohde Viscometer LUV-A12
  • 0.3 - 50000 mm2/sMeasuring range
  • 6Measure position
  • 41 LBath volume
  • 0.01 sTiming accuracy
Cone Plate Viscometer LCPV-A10
  • ± 2 % (F.S)Accuracy
  • -1℃ to 150℃ (± 0.1℃)Temperature
  • Spindle No CAP-01 CAP-04
    Shear Rate 13.3 N 3.3 N
    Sample Volume 67µL 134µL
    LCPV-A10 (400rpm) 47-469 300-3,750
    LCPV-A10 (750rpm) 25-250 200-2,000
    LCPV-A10 (900rpm) 20-208 170-1,667
    Spindle Details
  • rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.sNote

Viscometer LVM-D11

  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range

Viscometer LVM-D10

  • 25 mPa.s to 1×10000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/minRotor speed
  • 45 to 200°CTemperature control range
Viscometer LVM-D12
  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range