Viscometer LVM-A42

Viscometer LVM-A42 a floor standing rotational digital viscometer used to measure viscosity of liquid sample, semi-solid sample at specified shear rates. Adapted with new ARM technology, built-in Linus system, offers R2 to R7 Rotors (6 standard rotors), viscosity range 200 to 26 M (mPa.s) and 0.3 to 100 rpm rotation speed range (total of 998 speed options). Features a 5-inch color touch screen with visual display of variety of parameters and working conditions to guide users through test creation and data gathering for fast and easy viscosity measurements. It offers several advantages, like measuring multiple parameters, rich display content, convenient operation, intuitive reading, high measuring precision, stable rotational speed, strong anti-interference performance, showing the curve of shear rate, and viscosity, and so on. Each viscosity measuring range is automatically calibrated by a computer with high precision, and less errors.

  • Rotational speed range 0.3 to 100 rpm
    Standard Rotor Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
    Viscosity measurement range Rotor R2 to R7:200 to 26 M (mPa.s)
    Standard Rotor Sample Dosage Rotor R1 to R7: 500 ml
    Measurement error ± 1 %
    Repetitive error ± 0.5 %
    Display 5 inch color touch screen
    Standard configuration Shows shear response, timing function
    Real time display viscosity curve Time-viscosity curve (standard), Temperature-viscosity curve (optional temperature probe)
    Kinematic viscosity Density of samples to be entered
    Temperature measurement function Standard temperature probe interface
    Automatic scanning function Automatically scan and recommend the preferred combination of rotor and rotation speed
    Maximum measurement range Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range
    Memory Built-in 30 program groups (includes rotor speed, temperature, time, etc.)
    Put a seal on Data, curve can be printed (standard print interface, need to buy printer)
    Data output interface USB, insertion of U disk, Copying data , RS232, Connection to Computer
    Power Supply AC 110V/50 HZ, AC220V/50Hz
    Dimension 300 × 300 × 450 mm
    Net Weight 6 kg
    • Adapted with new ARM technology, built-in Linus system
    • Stepless debugging (speed regulation), measures high viscosity samples
    • 5-inch touch screen with variety of parameters, working conditions: dynamic and Kinetic viscosity, shear rate, shear stress, temperature measurement, and visual display (graphic of curve, range overflow alarm, automatic scanning, date, time etc.)
    • Buil-in 30 group program measurement, real time display of viscosity curves, with data printing
    • High precision automatic measurement, range calibration by computer
    • Equipped with timing measurement function, convenient adjustment of test paramters
    • Standard USB interace, insertion of U disk to copy data directly
    • Optional Pt100 temeprature probe with wide temperature range from -20 to 300°C
  • Viscometer also known as rheometer is a measuring instrument used to determine a fluid's internal flow resistance or viscosity. It finds application in adhesive, latex, paint, cosmetics, ink, pulp, food, oil, starch, solvent, biochemical products and other industries.

  • Optional Rotors Details
    Optional Rotors Enhanced ultra-low viscosity adapter ULR,
    Small sample adapters (Rotor 21, 27, 28, 29)
    Optional Rotor Viscosity Measurement Range URL: 12.8 to 1 K
    Rotor 21: 100 to 333 K
    Rotor 27: 500 to 1.7 K
    Rotor 28: 1K to 3.3 M
    Rotor 29: 2K to 6.6 M
    Optional Rotor Sample Dosage URL: 21 ml, Rotor 21: 7.8 ml, Rotor 27: 11.3ml, Rotor 28: 12.6 ml, Rotor 29: 11.5 ml

Viscometer LVM-A10

  • 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cPMeasuring range
  • 0.1 - 200 rpmRotating speed
  • ± 1.0 % full rangeMeasuring Error (Newtonian liquid)
  • ± 0.5 %Repeatability error (Newtonian liquid))

Viscometer LVM-D10

  • 25 mPa.s to 1×10000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-C12

  • 1 to 200000 mPa.sMeasuring range
  • 0.3/0.6/1.5/3.6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)
Viscometer LVM-C10
  • 1 to 100000 mPa.sMeasuring range
  • 3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)
Viscometer LVM-D12
  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-A41

  • 0.3 to 100 rpmRotational speed range
  • Rotor R2 to R7 (6, Standard), R1 (Apolegamy)Standard Rotor
  • Rotor R2 to R7:100 to 4000 M (mPa.s)Viscosity measurement range
  • Rotor R1 to R7: 500 mlStandard Rotor Sample Dosage

Viscometer LVM-C11

  • 1 to 100000 mPa.sMeasuring range
  • 3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±0.5%Measuring Error (Newtonian liquid)

Viscometer LVM-A23

  • HB: 800 to 104000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0 % (of full range)Accuracy
Viscometer LVM-D11
  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range
Viscometer LVM-A22
  • HA: 200 to 26000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0 % (of full range)Accuracy

Viscometer LVM-A40

  • 3 to 1600000 M (mPa.s)Viscosity Range
  • 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpmRotation speed range
  • 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 mlSpindles
  • 18#,25#,31#,34# (standard configuration)Rotor

Viscometer LVM-B11

  • 0.1 to 2,000,000 mPa.sMeasuring range
  • 0.3/0.6/1.5/3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)

Viscometer LVM-A31

  • RV: 100 to 40000000 mPa.sViscosity Range
  • 0.1 to 250 rpmRotation speed range
  • (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0% (of full range)Accuracy
Viscometer LVM-A20
  • LV: 1 to 2000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • LV: (1#, 2#, 3#, 4# spindles) (0# is optional)Spindles
  • ± 1.0 % (of full range)Accuracy
Viscometer LVM-D20
  • 40.2 KU to 141.0 KU
    32 g to 1099 g
    27 to 5250 CP
    Viscosity Range
  • 200±0.1 rpmRotation speed range
  • ± 3 %Accuracy
  • ±1.5 %Repeatability

Ubbelohde Viscometer LUV-A10

  • 0.3 - 50000 mm2/sMeasuring range
  • 2Measure position
  • 25 LBath volume
  • 0.01 sTiming accuracy

Ubbelohde Viscometer LUV-A12

  • 0.3 - 50000 mm2/sMeasuring range
  • 6Measure position
  • 41 LBath volume
  • 0.01 sTiming accuracy
Ubbelohde Viscometer LUV-A11
  • 0.3 - 50000 mm2/sMeasuring range
  • 4Measure position
  • 33 LBath volume
  • 0.01 sTiming accuracy
Viscometer LVM-D10
  • 25 mPa.s to 1×10000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-D12

  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-D11

  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range
Cone Plate Viscometer LCPV-A10
  • ± 2 % (F.S)Accuracy
  • -1℃ to 150℃ (± 0.1℃)Temperature
  • Spindle No CAP-01 CAP-04
    Shear Rate 13.3 N 3.3 N
    Sample Volume 67µL 134µL
    LCPV-A10 (400rpm) 47-469 300-3,750
    LCPV-A10 (750rpm) 25-250 200-2,000
    LCPV-A10 (900rpm) 20-208 170-1,667
    Spindle Details
  • rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.sNote