Viscometer LVM-B11

Viscometer LVM-B11 is used to determine a fluid's internal flow resistance or viscosity. This viscometer has bright, easy to read LCD digital display. The viscometer is useful in any area that requires the study of flow of liquids properties. It is user-friendly, and portable in nature.

  • Measuring range 0.1 to 2,000,000 mPa.s
    Rotating speed 0.3/0.6/1.5/3/6/12/30/60 (r/min)
    Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
    Measuring Error (Newtonian liquid) ±1%
    Repeatability error (Newtonian liquid)) ±0.5%
    Time function
    Power 110 V/60 Hz or 220 V/50 Hz
    Data output RS232C/USB
    Dimension 300 ×300 ×450 mm
    Net weight 7.5 kg
    Gross weight 8 kg
    • LCD panel displays measurement data without secondary calculations
    • Optional temperature probe for the real time measurement
    • Automatic scanner for selecting the best combination of rotor and rotating speed for the test
    • Optional data processing software with real-time recording of viscosity
  • Viscometer finds major applications in chemical and material industry, cosmetics, petroleum industry, research institutes, for analysis of fluids.

  • Accessories No. Name
    1 Rotor protection frame
    2 (1, 2, 3, 4) number rotor
  • Accessories No. Name
    1 Constant temperature water bath, 10 to 100°C, only 220 V
    2 Thermal Printer (with 1 roller paper)
    3 Temperature probe
    4 Ultra-low viscosity adapter (0 # rotor)
    5 Thermostatic cup
    6 PC Software RS232-USB Line
    7 Calibrate silicone oil 400ml

Viscometer LVM-D11

  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range

Viscometer LVM-A42

  • 0.3 to 100 rpmRotational speed range
  • Rotor R2 to R7 (6, Standard), R1 (Apolegamy)Standard Rotor
  • Rotor R2 to R7:200 to 26 M (mPa.s)Viscosity measurement range
  • Rotor R1 to R7: 500 mlStandard Rotor Sample Dosage

Viscometer LVM-C10

  • 1 to 100000 mPa.sMeasuring range
  • 3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)
Viscometer LVM-A31
  • RV: 100 to 40000000 mPa.sViscosity Range
  • 0.1 to 250 rpmRotation speed range
  • (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0% (of full range)Accuracy
Viscometer LVM-A20
  • LV: 1 to 2000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • LV: (1#, 2#, 3#, 4# spindles) (0# is optional)Spindles
  • ± 1.0 % (of full range)Accuracy

Viscometer LVM-A21

  • RV: 100 to 13000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0 % (of full range)Accuracy

Viscometer LVM-D12

  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-D10

  • 25 mPa.s to 1×10000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/minRotor speed
  • 45 to 200°CTemperature control range
Viscometer LVM-B10
  • 0.1 to 100,000 mPa.sMeasuring range
  • 6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)
Viscometer LVM-A22
  • HA: 200 to 26000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0 % (of full range)Accuracy

Viscometer LVM-C12

  • 1 to 200000 mPa.sMeasuring range
  • 0.3/0.6/1.5/3.6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)

Viscometer LVM-A30

  • LV: 1 to 6000000 mPa.sViscosity Range
  • 0.1 to 250 rpmRotation speed range
  • (1#, 2#, 3#, 4# spindles) (0# is optional)Spindles
  • ± 1.0% (of full range)Accuracy

Viscometer LVM-A40

  • 3 to 1600000 M (mPa.s)Viscosity Range
  • 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpmRotation speed range
  • 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 mlSpindles
  • 18#,25#,31#,34# (standard configuration)Rotor
Viscometer LVM-D20
  • 40.2 KU to 141.0 KU
    32 g to 1099 g
    27 to 5250 CP
    Viscosity Range
  • 200±0.1 rpmRotation speed range
  • ± 3 %Accuracy
  • ±1.5 %Repeatability
Viscometer LVM-C11
  • 1 to 100000 mPa.sMeasuring range
  • 3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±0.5%Measuring Error (Newtonian liquid)

Cone Plate Viscometer LCPV-A10

  • ± 2 % (F.S)Accuracy
  • -1℃ to 150℃ (± 0.1℃)Temperature
  • Spindle No CAP-01 CAP-04
    Shear Rate 13.3 N 3.3 N
    Sample Volume 67µL 134µL
    LCPV-A10 (400rpm) 47-469 300-3,750
    LCPV-A10 (750rpm) 25-250 200-2,000
    LCPV-A10 (900rpm) 20-208 170-1,667
    Spindle Details
  • rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.sNote

Ubbelohde Viscometer LUV-A11

  • 0.3 - 50000 mm2/sMeasuring range
  • 4Measure position
  • 33 LBath volume
  • 0.01 sTiming accuracy
Ubbelohde Viscometer LUV-A10
  • 0.3 - 50000 mm2/sMeasuring range
  • 2Measure position
  • 25 LBath volume
  • 0.01 sTiming accuracy
Ubbelohde Viscometer LUV-A12
  • 0.3 - 50000 mm2/sMeasuring range
  • 6Measure position
  • 41 LBath volume
  • 0.01 sTiming accuracy

Viscometer LVM-D12

  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-D11

  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range
Viscometer LVM-D10
  • 25 mPa.s to 1×10000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/minRotor speed
  • 45 to 200°CTemperature control range