Xenon Test Chamber LXC-A22

Xenon Test Chamber LXC-A22 is a benchtop model with single xenon arc lamp and is available with optional automatic water supply. A large spectrum of environmental condition based test materials can be tested using this model.

  • Temperature Range RT+50℃ to 70℃
    Temperature Fluctuation ±3℃
    Cooling Way Air-cooled
    Raining Time 0-99min adjustable
    Irradiation Strength 400-700w/m2
    Wavelength 290-800nm
    Dimming Range 5%-100%
    Lamp Power 2.5kW
    Total Power 4.5kW
    Power Supply AC380V±10% 50±0.5Hz (three-phase five wire system)
    Interior Size(W×D×H) 500×320×300mm
    Exterior Size(W×D×H) 900×800×750mm
    Standard Configurations Stainless steel sample holder, one air-cooled xenon lamp, one portable irradiation meter
    • Microcomputer PID temperature controller
    • PT100 platinum resistance thermometer as temperature sensor
    • Temperature auto-monitoring
    • Possess function of automatic calculus
    • Air cooled xenon arc lamp as light source
    • Has hand-held irradiator meter
    • Outer case made up of high quality A3 color plates through CNC machine surface sprayed with plastics
    • Inner case made up of SUS304 high-grade stainless steel
    • Contact-less heating through SSR(Solid State Relay)
    • Over temperature, leakage, short circuit protection, overload short circuit protection, lack of water protector, alarms
  • It is used in different industries such as plastic, paint, dyeing, automobile, motorcycle, petrochemical, textile, leather products etc.

Related Products of Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Xenon Test Chamber LXC-A21

  • 300 - 420Bandwidth Measurement (nm)
  • 34Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range

Xenon Test Chamber LXC-A20

  • 280 ~ 800Bandwidth Measurement (nm)
  • 28Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range

Xenon Test Chamber LXC-A10

  • 280 ~ 800Bandwidth Measurement (nm)
  • 28Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range
Xenon Test Chamber LXC-A11
  • 300 - 420Bandwidth Measurement (nm)
  • 34Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A21

  • RT + 100 °C ~ 630 °CTemperature Range
  • 30 % ~ 85 % RHHumidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 VTesting Voltage

UV Test Chamber LUVC-A20

  • RT + 100 °C ~ 850 °CTemperature Range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %Humidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 V (135 V)Testing Voltage
UV Test Chamber LUVC-A10
  • 50 °C to 75 °CUV Temperature
  • 48 piece (75 x 150 mm); 50 piece (75x 150 mm)Testing Capacity
  • 136 kgWeight
  • Distilled water, 8liters per dayWater Consumption

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A10
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
  • ± 0.5 ℃Temperature fluctuation
  • Ambient ~ 0 ℃ within 20 minSpeed rate for cooling

Ozone Test Chamber LOC-A12

  • 600Diameter of holder (mm)
  • 220Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Ozone Test Chamber LOC-A11

  • 400Diameter of holder (mm)
  • 180Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Plant Growth Chamber LPGC-A12
  • 800 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range
Plant Growth Chamber LPGC-A11
  • 450 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

Plant Growth Chamber LPGC-A10

  • 300 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Sand and Dust Test Chamber LSC-A11

  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire
Sand and Dust Test Chamber LSC-A10
  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire
Sand and Dust Test Chamber LSC-A12
  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire

Xenon Test Chamber

We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.

Xenon Test Chamber LXC-A10

  • 280 ~ 800Bandwidth Measurement (nm)
  • 28Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range

Xenon Test Chamber LXC-A22

  • RT+50℃ to 70℃Temperature Range
  • ±3℃Temperature Fluctuation
  • Air-cooledCooling Way
  • 0-99min adjustableRaining Time
Xenon Test Chamber LXC-A11
  • 300 - 420Bandwidth Measurement (nm)
  • 34Specimen Capacity (pcs)
  • 80 × 15Specimen holder size (mm)
  • Ambient ~ 100 ℃ ± 2 °CChamber Temperature Range