UV Test Chamber LUVC-A21

Labtron model of LUVC-A21 is equipped with UV carbon lamps to carry out UV testing along with temperature, humidity and rain to test the aging resistance to provide an accurate environment condition to give precise test results.

  • Temperature Range RT + 100 °C ~ 630 °C
    Humidity range 30 % ~ 85 % RH
    Testing Time 20 hours
    Testing Voltage 120 V ~ 145 V
    Testing Current 15 A ~ 17 A
    Black Panel Temperature
    Black Bulb Thermometer 63 °C ± 30 °C ~ 83 °C ± 30 °C
    Sample Rack Size 508Ø
    Sample Rack Rotation Speed 3 rpm
    Specimens capacity
    Specimen Sample Rack 248 x 50 mm, 20 pcs
    UV wavelength
    UV Temperature
    Testing Capacity
    Irradiance Control
    Irradiation Source
    Weight
    Water Spray
    Water Consumption
    Distance of Specimen and lamp
    Internal dimensions
    Overall dimensions
    Dimension(W x D x H) 130 x 130 x 200 cm
    Nominal power
    Power 1∮ 220 V 6 KVA
    • Light and temperature can be controlled through an user friendly coloured touch screen
    • Light intensity control system allow users to set different test light intensity based on test requirements
    • Designed to perform UV light testing with the help of UV carbon lamps
    • Used to test aging-resistance of material when exposed to sunlight, temperature, humidity and rain
  • The UV Test Chamber is widely used in plastics, printing and packaging, paint, resins, adhesives, automotive, cosmetics, metals, electroplating, medicine, etc.

Related Products of UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A20

  • RT + 100 °C ~ 850 °CTemperature Range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %Humidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 V (135 V)Testing Voltage

UV Test Chamber LUVC-A10

  • 50 °C to 75 °CUV Temperature
  • 48 piece (75 x 150 mm); 50 piece (75x 150 mm)Testing Capacity
  • 136 kgWeight
  • Distilled water, 8liters per dayWater Consumption

Salt Spray Test Chamber

Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.

Salt Spray Test Chamber LSSC-A10

  • 110 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Salt Spray Test Chamber LSSC-A11

  • 326 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation
Salt Spray Test Chamber LSSC-A12
  • 410 LTesting room capacity
  • Ambient to +60°CTemperature range
  • 95 to 98% RHHumidity range
  • ± 0.5 ℃Temperature Fluctuation

Temperature and Humidity Test Chamber

Labtron offers temperature and humidity test chambers which are used in various industries to test large equipments such as automotive parts by controlling the temperature and humidity. It is highly stable and provides enough space to work.

Temperature and Humidity Test Chamber LTHC-B10
  • 100 LCapacity
  • (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃Temperature range
  • 1 ℃ / minTemperature cooling rate
  • 860 x 1050 x 1620 mmOverall dimension (D x W x H)

Temperature and Humidity Test Chamber LTHC-A11

  • 80 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition

Temperature and Humidity Test Chamber LTHC-A10

  • 50 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Sand and Dust Test Chamber LSC-A10
  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire
Sand and Dust Test Chamber LSC-A12
  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire

Sand and Dust Test Chamber LSC-A11

  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire

Plant Growth Chamber

Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.

Plant Growth Chamber LPGC-A10

  • 300 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range
Plant Growth Chamber LPGC-A12
  • 800 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range
Plant Growth Chamber LPGC-A11
  • 450 LChamber Volume
  • 3(PCS)Shelves
  • 0.1 ℃Display Resolution
  • Without Lighting: 0 to 50℃
    With lighting:10 to 50℃
    Temperature Range

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A10

  • 50 °C to 75 °CUV Temperature
  • 48 piece (75 x 150 mm); 50 piece (75x 150 mm)Testing Capacity
  • 136 kgWeight
  • Distilled water, 8liters per dayWater Consumption

UV Test Chamber LUVC-A20

  • RT + 100 °C ~ 850 °CTemperature Range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %Humidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 V (135 V)Testing Voltage
UV Test Chamber LUVC-A21
  • RT + 100 °C ~ 630 °CTemperature Range
  • 30 % ~ 85 % RHHumidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 VTesting Voltage