Viscometer LVM-A22

Viscometer LVM-A22 is a floor standing instrument used to measure viscosity of fluid sample at specified shear rates. This model is HA (High viscosity) range viscometer which uses six set of spindles with a spindle protector. Easy operations, anti-static shell, metal lifter, temperature probe, durable axle, data transfer port, external storage supports, a lot of rotate speed options, etc. are some of the features which ensures safety of user along with ease of handling. It is used in medical laboratories, paint industry, oil and petroleum industry, etc.

  • Viscosity Range HA: 200 to 26000000 mPa.s
    Rotation speed range 0.3 to 100 rpm (stepless)
    Spindles HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
    Accuracy ± 1.0 % (of full range)
    Repeatability 0.005
    Options in Unit mPa.s, Pa.s, dPa.s, cP, P, cPs
    Probe Built-in RTD temperature probe
    Display 7 inch touch screen display
    Packaging Dimension 410 × 380 × 410 mm
    Net Weight 10 kg
    Gross Weight 12 kg
    • ARM chip for fast data processing
    • 7 inch touch screen display
    • Optional DV software
    • Displays shear stress and rate
    • Built-in RTD temperature probe
    • Interactive interface
    • Password protected temperature and correction factor
    • Automatically switches between dynamic and kinematic viscosity
    • Options between viscosity units
    • Alarm system when measurement range is crossed
    • Continuous testing is possible
    • Choices available for interface style
    • Computerized Calibration process
  • It is used to measure viscosity of fluid samples like latex, glue, paint, oil, polymer solutions, medicine, cosmetic, juice etc.

  • Sr. No. Accessories Name
    1 DV Software
    2 Thermostatic water bath
    3 Ultra-low viscosity adapter
    4 Small sample adapter
    5 Micro printer
    6 External circulatory glass beaker

Viscometer LVM-B11

  • 0.1 to 2,000,000 mPa.sMeasuring range
  • 0.3/0.6/1.5/3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)

Viscometer LVM-A10

  • 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cPMeasuring range
  • 0.1 - 200 rpmRotating speed
  • ± 1.0 % full rangeMeasuring Error (Newtonian liquid)
  • ± 0.5 %Repeatability error (Newtonian liquid))

Viscometer LVM-D20

  • 40.2 KU to 141.0 KU
    32 g to 1099 g
    27 to 5250 CP
    Viscosity Range
  • 200±0.1 rpmRotation speed range
  • ± 3 %Accuracy
  • ±1.5 %Repeatability
Viscometer LVM-A42
  • 0.3 to 100 rpmRotational speed range
  • Rotor R2 to R7 (6, Standard), R1 (Apolegamy)Standard Rotor
  • Rotor R2 to R7:200 to 26 M (mPa.s)Viscosity measurement range
  • Rotor R1 to R7: 500 mlStandard Rotor Sample Dosage
Viscometer LVM-D12
  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-A41

  • 0.3 to 100 rpmRotational speed range
  • Rotor R2 to R7 (6, Standard), R1 (Apolegamy)Standard Rotor
  • Rotor R2 to R7:100 to 4000 M (mPa.s)Viscosity measurement range
  • Rotor R1 to R7: 500 mlStandard Rotor Sample Dosage

Viscometer LVM-A21

  • RV: 100 to 13000000 mPa.sViscosity Range
  • 0.3 to 100 rpm (stepless)Rotation speed range
  • RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)Spindles
  • ± 1.0 % (of full range)Accuracy

Viscometer LVM-C12

  • 1 to 200000 mPa.sMeasuring range
  • 0.3/0.6/1.5/3.6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)
Viscometer LVM-C11
  • 1 to 100000 mPa.sMeasuring range
  • 3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±0.5%Measuring Error (Newtonian liquid)
Viscometer LVM-A40
  • 3 to 1600000 M (mPa.s)Viscosity Range
  • 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpmRotation speed range
  • 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 mlSpindles
  • 18#,25#,31#,34# (standard configuration)Rotor

Viscometer LVM-D10

  • 25 mPa.s to 1×10000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-C10

  • 1 to 100000 mPa.sMeasuring range
  • 3/6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)

Viscometer LVM-B10

  • 0.1 to 100,000 mPa.sMeasuring range
  • 6/12/30/60 (r/min)Rotating speed
  • 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotarRotor
  • ±1%Measuring Error (Newtonian liquid)
Viscometer LVM-D11
  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range
Viscometer LVM-A30
  • LV: 1 to 6000000 mPa.sViscosity Range
  • 0.1 to 250 rpmRotation speed range
  • (1#, 2#, 3#, 4# spindles) (0# is optional)Spindles
  • ± 1.0% (of full range)Accuracy

Ubbelohde Viscometer LUV-A10

  • 0.3 - 50000 mm2/sMeasuring range
  • 2Measure position
  • 25 LBath volume
  • 0.01 sTiming accuracy

Ubbelohde Viscometer LUV-A12

  • 0.3 - 50000 mm2/sMeasuring range
  • 6Measure position
  • 41 LBath volume
  • 0.01 sTiming accuracy
Ubbelohde Viscometer LUV-A11
  • 0.3 - 50000 mm2/sMeasuring range
  • 4Measure position
  • 33 LBath volume
  • 0.01 sTiming accuracy
Cone Plate Viscometer LCPV-A10
  • ± 2 % (F.S)Accuracy
  • -1℃ to 150℃ (± 0.1℃)Temperature
  • Spindle No CAP-01 CAP-04
    Shear Rate 13.3 N 3.3 N
    Sample Volume 67µL 134µL
    LCPV-A10 (400rpm) 47-469 300-3,750
    LCPV-A10 (750rpm) 25-250 200-2,000
    LCPV-A10 (900rpm) 20-208 170-1,667
    Spindle Details
  • rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.sNote

Viscometer LVM-D12

  • 100 mPa.s to 2000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • 45 to 200°CTemperature control range

Viscometer LVM-D11

  • 100 mPa.s to 200000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • 5, 10, 20, 50 r/minRotor speed
  • Room temperature to 200°CTemperature control range
Viscometer LVM-D10
  • 25 mPa.s to 1×10000000 mPa.sMeasurement range
  • Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)Rotors
  • (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/minRotor speed
  • 45 to 200°CTemperature control range