Dissolution tester LDLT-A15

Dissolution tester LDLT- A15 is adopted with microprocessor controlled technology, automatically controls the temperature, time and rotation speed of experiment. The vessels and poles are fitted in backward or front position. The basket and paddle units of these dissolution tester are made of high quality SUS316L stainless steel. Equipped with magnetism-pumped circular water current, maintains uniform temperature of the liquid throughout the water bath.

  • No of vessels 8
    No of poles 6
    Position of vessels and poles Six vessels and six poles in front and other two vessels at back
    Head part movement Electrically turn over
    Preset time
    Preset time (for 9 points) 1 to 999 mins
    Dimension (L × W × H) 960 × 520 × 480 mm
    Speed range 20 to 200 rpm
    Speed accuracy ± 2 rpm
    Temperature range Ambient to 45°C
    Temperature accuracy ± 0.3°C
    Time accuracy ± 0.5 mins
    Paddle radial run out ± 0.5 mm
    Basket radial run out ± 1.0 mm
    Power supply 220 V, 50 Hz
    Power 600 W
    Gross Weight 86 kg
    • LCD display shows preset and real data
    • Automatic beeper sound for test point
    • Microprocessor controlled technology
    • Splash proof alphanumeric keypad
    • Auto test, auto diagnosis, auto alarm functions
    • Six vessels and six poles in front and other two vessels at back
    • Automatic up and down movement of head part
  • Used to detect rate (velocity & extent) dissolution limit of pharmaceutical drugs in the form of tablets, pills, capsules, etc. in prescriptive form.

  • Accessories no. Name Capacity Qty.
    1 Beaker 1000 ml 8
    Can select any one capacity for beaker
    1 Beaker 1200 ml 8

Dissolution tester LDLT-A16

  • 8No of vessels
  • 8No of poles
  • Four vessels and four poles in front and others at backPosition of vessels and poles
  • Electrically turn overHead part movement

Dissolution tester LDLT-A12

  • 6No of vessels
  • 6No of poles
  • Six vessel and six pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement

Dissolution tester LDLT-A10

  • 1No of vessels
  • 1No of poles
  • One vessel and one pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement
Dissolution tester LDLT-A17
  • 12No of vessels
  • 12No of poles
  • Six vessels and six poles in front and other six poles and vessels at backPosition of vessels and poles
  • Electrically (automatic) turn overHead part movement
Dissolution tester LDLT-A14
  • 8No of vessels
  • 6No of poles
  • Six vessels and six poles in front and other two vessels at backPosition of vessels and poles
  • Manually turn overHead part movement

Dissolution tester LDLT-A11

  • 3No of vessels
  • 3No of poles
  • Three vessel and three pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement

Dissolution tester LDLT-A13

  • 6No of vessels
  • 6No of poles
  • Six vessel and six pole arranged on one linePosition of vessels and poles
  • Electrically turn overHead part movement

Dissolution tester LDLT-A12

  • 6No of vessels
  • 6No of poles
  • Six vessel and six pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement

Dissolution tester LDLT-A10

  • 1No of vessels
  • 1No of poles
  • One vessel and one pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement
Dissolution tester LDLT-A11
  • 3No of vessels
  • 3No of poles
  • Three vessel and three pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement
Disintegration tester LDIT-A11
  • 2 setsNumber of basket lifting set
  • 30 to 32/ minLifting frequency of the basket
  • 55 ± 1 mmLifting distance of basket
  • 25 ± 2 mmMinimum spacing from screen to bottom of beaker

Disintegration tester LDIT-A10

  • 1 setNumber of basket lifting set
  • 30 to 32/ minLifting frequency of the basket
  • 55 ± 1 mmLifting distance of basket
  • 25 ± 2 mmMinimum spacing from screen to bottom of beaker

Disintegration tester LDIT-A12

  • 3 setsNumber of basket lifting set
  • 30 to 32/ minLifting frequency of the basket
  • 55 ± 1 mmLifting distance of basket
  • 25 ± 2 mmMinimum spacing from screen to bottom of beaker
Tap Density Tester LTDT-A10
  • 1Work Station
  • ≤ 250 mlSample Volume
  • ≤ 500 gSample Weight
  • 0 to 99999 (set 0 to output bulk density)Number of Tapping
Tap Density Tester LTDT-A12
  • 3Work Station
  • ≤ 100 mlSample Volume
  • ≤ 500 gSample Weight
  • 0 to 99999 (set 0 to output bulk density)Number of Tapping

Tap Density Tester LTDT-A11

  • 2Work Station
  • ≤ 250 mlSample Volume
  • ≤ 500 gSample Weight
  • 0 to 99999 (set 0 to output bulk density)Number of Tapping

Tablet Counting Machine LTCM-A10

  • 400 mmDiameter of counting plate
  • 5 to 100 (optional)Hole No. of counting slide/range
  • 10 to 20 vials/ minProduction efficiency
  • 36 bottles/ minuteRate of Bottles
Tablet Hardness tester LTHT-A10
  • 2 to 196 N, 0.2 to 20 kgHardness measurement range
  • 2 to 20 mmTablet diameter
  • ≤ 100 tabletsNo. of testing tablets in each group
  • NoBuilt in printer
Tablet Hardness tester LTHT-A11
  • 2 to 200 N, 0.2 to 20 kgHardness measurement range
  • 2 to 40 mmTablet diameter
  • ≤ 100 tabletsNo. of testing tablets in each group
  • NoBuilt in printer

Tablet Hardness tester LTHT-A12

  • 2 to 200 N, 0.2 to 20 kgHardness measurement range
  • 2 to 40 mmTablet diameter
  • ≤ 100 tabletsNo. of testing tablets in each group
  • YesBuilt in printer