Dissolution tester LDLT-A10

Dissolution tester LDLT-A10 is adopted with microprocessor controlled technology, automatically controls the temperature, time and rotation speed of experiment. Its test parameters can be preset manually as per experiment. Equipped with magnetism-pumped circular water current, maintains uniform temperature of the liquid throughout the water bath. The basket and paddle units of these dissolution tester are made of high quality SUS316L stainless steel.

  • No of vessels 1
    No of poles 1
    Position of vessels and poles One vessel and one pole arranged on one line
    Head part movement Manually turn over
    Preset time
    Preset time (for 9 points) 5 to 900 mins
    Dimension (L × W × H) 260 × 300 × 480 mm
    Speed range 20 to 200 rpm
    Speed accuracy ± 2 rpm
    Temperature range Ambient to 45°C
    Temperature accuracy ± 0.3°C
    Time accuracy ± 0.5 mins
    Paddle radial run out ± 0.5 mm
    Basket radial run out ± 1.0 mm
    Power supply 220 V, 50 Hz
    Power 600 W
    Gross Weight 20 kg
    • LCD display shows preset and real data
    • Microprocessor controlled technology
    • Operations by convenient key buttons
    • Auto test, auto diagnosis, auto alarm functions
    • One vessel and one pole arranged on one line
    • Manually turned over smooth and flexible head part
  • Used to detect rate (velocity & extent) dissolution limit of pharmaceutical drugs in the form of tablets, pills, capsules, etc. in prescriptive form.

  • Accessories no. Name Capacity Qty.
    1 Beaker 1000 ml 1
    Can select any one capacity for beaker
    1 Beaker 1200 ml 1

Dissolution tester LDLT-A12

  • 6No of vessels
  • 6No of poles
  • Six vessel and six pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement

Dissolution tester LDLT-A13

  • 6No of vessels
  • 6No of poles
  • Six vessel and six pole arranged on one linePosition of vessels and poles
  • Electrically turn overHead part movement

Dissolution tester LDLT-A14

  • 8No of vessels
  • 6No of poles
  • Six vessels and six poles in front and other two vessels at backPosition of vessels and poles
  • Manually turn overHead part movement
Dissolution tester LDLT-A15
  • 8No of vessels
  • 6No of poles
  • Six vessels and six poles in front and other two vessels at backPosition of vessels and poles
  • Electrically turn overHead part movement
Dissolution tester LDLT-A11
  • 3No of vessels
  • 3No of poles
  • Three vessel and three pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement

Dissolution tester LDLT-A17

  • 12No of vessels
  • 12No of poles
  • Six vessels and six poles in front and other six poles and vessels at backPosition of vessels and poles
  • Electrically (automatic) turn overHead part movement

Dissolution tester LDLT-A16

  • 8No of vessels
  • 8No of poles
  • Four vessels and four poles in front and others at backPosition of vessels and poles
  • Electrically turn overHead part movement

Friability Tester LTFT-A10

  • 2Number of cylinder
  • 25 rpmRotating speed of cylinders
  • ± 1 rpmRotating accuracy
  • Adopted with countdown, 100 turns can be set arbitrarilyCounting mode

Friability Tester LTFT-A11

  • 2Number of cylinder
  • 20 to 100 rpm can be set arbitrarilyRotating speed of cylinders
  • ± 1 rpmRotating accuracy
  • Adopted with countdown, 5 to 900 turns can be set arbitrarilyCounting mode
Friability Tester LTFT-A12
  • 2Number of cylinder
  • 25 rpm can be set arbitrarilyRotating speed of cylinders
  • ± 1 rpmRotating accuracy
  • Adopted with countdown, 5 to 900 turns can be set arbitrarilyCounting mode
Dissolution tester LDLT-A10
  • 1No of vessels
  • 1No of poles
  • One vessel and one pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement

Dissolution tester LDLT-A12

  • 6No of vessels
  • 6No of poles
  • Six vessel and six pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement

Dissolution tester LDLT-A11

  • 3No of vessels
  • 3No of poles
  • Three vessel and three pole arranged on one linePosition of vessels and poles
  • Manually turn overHead part movement
Powder Flowability Tester LPFL-A10
  • Diameter 100 mmDisc
  • Outer diameter 155 mmFunnel Outer Diameter
  • 145 mmFunnel Inner Diameter
  • Surfactant Powder and Particles, non-agglomerated powderTest Sample
Tablet Counting Machine LTCM-A10
  • 400 mmDiameter of counting plate
  • 5 to 100 (optional)Hole No. of counting slide/range
  • 10 to 20 vials/ minProduction efficiency
  • 36 bottles/ minuteRate of Bottles

Tap Density Tester LTDT-A12

  • 3Work Station
  • ≤ 100 mlSample Volume
  • ≤ 500 gSample Weight
  • 0 to 99999 (set 0 to output bulk density)Number of Tapping

Tap Density Tester LTDT-A11

  • 2Work Station
  • ≤ 250 mlSample Volume
  • ≤ 500 gSample Weight
  • 0 to 99999 (set 0 to output bulk density)Number of Tapping
Tap Density Tester LTDT-A10
  • 1Work Station
  • ≤ 250 mlSample Volume
  • ≤ 500 gSample Weight