HPLC system LHLC-B11

This HPLC system delivers high quality performance and reliable results in order to meet the stringent requirements of the customer. To meet GMP/GLP requirements of the instrument, this HPLC system has hardware with VP function which records maintenance information and operations.

  • High pressure pump High pressure constant-current infusion pump
    Infusion Way Micro volume series dual-piston
    Infusion pressure 0 - 9999 Psi
    Flow rate ≤ 0.5 %
    Flow rate range 0.001 - 9.999 mL / min (in 0.001 mL / min increments)
    Stability error for the flow rate ≤ 0.2 % RSD
    Gradient error ± 1 % (0 - 100 % water/acetone solvent)
    Pressure pulsation < 15 Psi (flow rate 1 mL / min, pressure 600 - 1600 Psi)
    Air tightness Pressure 5400 Psi, 10 min time, pressure drop < 400 Psi
    Time program function Yes
    Size (W × H × D) 260 × 130 × 420 mm
    Weight 11 kg
    Operation temperature 4 - 40 ºC
    UV detector
    • Wavelength range: 240
    • Wavelength error: ≤ 1 nm
    • Wavelength repeatability error: ≤ ± 0.1 nm
    • Dynamic noise: ≤ ± 0.75 × 10<sup>-5</sup> AU (methyl alcohol 1 mL / min, 254 nm, 20 ºC)
    • Static noise: ≤ ± 0.5 × 10<sup>-5</sup> A (empty cell, response time, 1 second, 20 ºC)
    • Dynamic baseline Drift: ≤ ± 1 × 10<sup>-4</sup> AU / h (methyl alcohol 1 mL / min, 254 nm, 20 ºC)
    • Static baseline Drift: ≤ 0.5 × 10<sup>-4</sup> (empty cell, response time, 1 second, 20 ºC)
    • Linear range: ≥ 104
    • Limit of detection: ≤ 1 × 10<sup>-9</sup> g / ml (Naphthalene methyl alcohol solvent)
    • Quantitative repeatability: RSD 6 ≤ 0.1 %
    • Qualitative repeatability: RSD 6 ≤ 0.5 %
    • Spectrum band width: 6 nm
    • Flow cell volume: 8 µL
    • Optical path: 10 nm
    • Time program function: Yes
    • Size (W × H × D): 260 × 130 × 420 mm
    • Weight: 11 kg
    • Operation Temperature: 4 - 40 ºC
    • High pressure constant-current infusion pump
    • Even mixing of the injections using mixers
    • Supreme appearance to meet the customer’s visual requirements
    • Simple, easy to use operations
    • UV detector unit consists of dual beam monochromator, light battery, deuterium lamp
  • This HPLC has applications in the scientific research studies, detection of residual amount in medicine, food, alcohol and in chemical analysis.

HPLC system LHLC-A11

  • Two sets of pumpHigh pressure pump
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)Flow rate range
  • ≤ 0.5 MPa (0 - 42 MPa)Pressure range
  • RSD < 0.06 %Flow rate precision

HPLC system LHLC-A10

  • Single pumpHigh pressure pump
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)Flow rate range
  • ≤ 0.5 MPa (0 - 42 MPa)Pressure range
  • RSD < 0.06 %Flow rate precision

HPLC system LHLC-B10

  • High pressure gradient pumpHigh pressure pump
  • 45 MPa, Stainless steel pumpPeak operating pressure
  • ± 0.02 MPaPressure
  • 0.001 - 9.999 mL / minFlow rate range

Analytical HPLC-A7832

  • Model No HPD-A20 HPD-A21
    Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
    Wavelength accuracy ± 0.5 nm ± 2 nm
    Wavelength repeatability 0.15 nm 0.3 nm
    Band width 8 nm 8 nm
    Optical path 10 nm 10 nm
    Deuterium lamp 190 to 400 nm 190 to 400 nm
    Tungsten lamp 400 to 800 nm 400 to 800 nm
    Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5
    Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4
    Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8
    Power 100 W 100 W
    Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz
    Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm
    Weight 9.5 kg 9.5 kg
    Detector Specifications
  • {"Flow rate range":"0.0001 to 10 ml \/ min","Maximum pressure":"50 MPa , 0 to 2 ml \/ min","Column size":"4.6 \u00d7 250 mm","Sample size":"5 \u00b5m","Pressure pulsation":"\u2264 1 % at 10 MPa","Flow rate accuracy":"\u00b1 0.15 % at 1 ml \/ min","Flow rate repeatability %":"\u2264 0.1","Gradient accuracy %":"\u00b1 1.5","Gradient repeatability %":"\u2264 0.2","Dimension":"460 \u00d7 310 \u00d7 180 mm","Power supply":"90 V","Weight":"11.6 kg"}Pump Specifications

Analytical HPLC-A7835

  • {"Model No":"HPP-B1","Flow rate range":"0.0001 to 10 ml \/ min","Maximum pressure":"42 MPa , 0 to 5 ml \/ min","Column size":"4.6 \u00d7 250 mm","Sample size":"5 \u03bcm","Pressure pulsation":"\u2264 1.5 % at 10 MPa","Flow rate accuracy":"\u00b1 0.2 % at 1 ml \/ min","Flow rate repeatability %":"\u2264 0.15","Gradient accuracy %":"\u00b1 2","Gradient repeatability %":"\u2264 0.2","Dimension":"450 \u00d7 260 \u00d7 190 mm","Power supply":"90 V to 240 V","Weight":"11.2 kg"}Pump Specifications
  • {"Model No":"HPD-B2","Wavelength range":"190 to 800 nm","Wavelength accuracy":"\u00b1 0.75 nm","Wavelength repeatability":"0.2 nm","Band width":"8 nm","Optical path":"10 nm","Deuterium lamp":"190 to 400 nm","Tungsten lamp":"400 to 800 nm","Baseline noise ( Static ) Au":"\u2264 \u00b1 0.5 \u00d7 10 -5<\/sup>","Baseline drift ( Static ) Au \/ h":"\u2264 1.5 x 10 -4<\/sup>","Minimum detection limit":"\u2264 4 x 10 -8<\/sup>","Power":"100 W","Power supply":"90 V \/ 50 to 60 Hz","Dimension":"460 \u00d7 260 \u00d7 190 mm","Weight":"9.2 kg"}Detector Specifications
Analytical HPLC-A7840
  • {"Solvent delivery":"Double plunger series mode, floating plunger design, single stroke volume 30 \u00b5l","Pump Head":"10 ml stainless steel pump head","Flow rate range":"0.001 to 9.999 ml \/ min","Flow rate increment":"0.001 ml\/min","Maximum pressure":"42 MPa","Column size":"4.6 \u00d7 250 mm 5 \u00b5m","Pipeline Size":"1\/16 inch","Flow rate accuracy":"\u00b1 0.5 %","Flow rate precision":"RSD \u2264 0.1%","Gradient accuracy %":"\u00b1 0.5 %","Gradient repeatability %":"RSD \u2264 0.15%","GLP":"Automatic recording of pump sealing ring working time","Display":"LCD backlight display","Power":"80 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension":"398 \u00d7 149 \u00d7 267 mm"}Pump Specifications
  • {"Wavelength range":"190 to 700 nm","Wavelength accuracy":"\u00b1 1 nm","Wavelength repeatability":"0.2 nm","Deuterium lamp":"190 to 400 nm","Tungsten lamp":"400 to 700 nm","Baseline noise ( Static ) Au":"1 \u00d7 10-5<\/sup> AU\/h at 254 nm with methanol\/water= 80\/20","Baseline drift ( Static ) Au \/ h":"1.5 \u00d7 10-4<\/sup> AU\/h at 254 nm with methanol\/ water= 80\/20","Time constants":"16 grades adjustable","Display":"LCD backlight display","GLP":"Total number of lights, lamp replacement time and product serial number","Power":"75 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension (L \u00d7 W \u00d7 H)":"398 \u00d7 149 \u00d7 267 mm"}Detector Specifications
HPLC system LHLC-A11
  • Two sets of pumpHigh pressure pump
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)Flow rate range
  • ≤ 0.5 MPa (0 - 42 MPa)Pressure range
  • RSD < 0.06 %Flow rate precision

HPLC system LHLC-B11

  • High pressure constant-current infusion pumpHigh pressure pump
  • Micro volume series dual-pistonInfusion Way
  • 0 - 9999 PsiInfusion pressure
  • ≤ 0.5 %Flow rate

HPLC system LHLC-A10

  • Single pumpHigh pressure pump
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)Flow rate range
  • ≤ 0.5 MPa (0 - 42 MPa)Pressure range
  • RSD < 0.06 %Flow rate precision