Vertical Autoclave LVA-B13

Vertical Autoclave LVA-B13 is top loading vertical pressure steam sterilizer with chamber capacity of 100 L, working sterilization temperature and pressure of 134°C and 0.22 MPa respectively. Designed with digital display of working status, with touch keypad and double stainless steel baskets to keep the sterilization material load. Material used stainless high-alloy steel body structure. Auto discharge the cool air, and steam discharging automatically after sterilization. It is used in pharmaceutical industry, medicine and health care industry.

  • Capacity 100 L
    Chamber volume 440 × 650 mm
    Working Temperature 134℃
    Working Pressure 0.22 MPa
    Max Working Pressure 0.23 MPa
    Time Range 0 to 99 min or 0 to 99 hour 59 min
    Sterilization Temperature Range 105 to 134℃
    Heat Average ≤± 1℃
    Power Consumption 4.5 kW
    Power Supply AC 220 V, 50 Hz
    Overall Dimension 590 × 590 × 1080 mm
    Packing Dimension 680 × 650 × 1220 mm
    Net weight 85 kg
    Gross weight 105 kg
    • Material used for body structure is high-alloy stainless steel
    • Designed with digital display indicates working status, touch keypad control panel
    • Over temperature & over pressure auto-protection
    • Sterilization Temperature ranges from 105 to 134℃
    • Designed with auto discharge the cool air, and steam discharging automatically after sterilization
    • Automatically shut off with beep alarm after sterilization
    • Dual stainless steel baskets as standard accessory
    • Equipped with movable casters for easy movement
    • Easy to operate, safe and reliable
  • Vertical autoclave used in pharmaceutical industry, medicine and health care industry, Biotechnology, Microbiology for effective sterilization of glassware’s, biological materials, culture media and others.

  • Accessories no.Name MaterialQuantity
    1Basket Stainless steel02 pcs

Related Products of Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Autoclave LVA-L21

  • 54 LCapacity
  • Diameter 325 × 460 mmChamber dimension
  • SUS 304Chamber material
  • (Diameter 300 × 200) × 3Stainless steel basket

Vertical Laboratory Autoclave LVA-G13

  • 100LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 440 × 650 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-I11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 320 × 610 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-J12
  • 75 LCapacity
  • 115 to 129 °CSterilization Temperature
  • 0.165 MPaSterilization Pressure
  • 388 × 530 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-B12
  • 75 LCapacity
  • 400 × 600 mmChamber volume
  • 134℃Working Temperature
  • 0.22 MPaWorking Pressure

Vertical Laboratory Autoclave LVA-I13

  • 100 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 388 × 670 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-I15

  • 150 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 460 × 760 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-C11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-H12
  • 75 LCapacity
  • 134°CWorking sterilization temperature
  • 0.22 MPaWorking sterilization pressure
  • 105°C to 134°CAdjustment of Temperature
Vertical Laboratory Autoclave LVA-J11
  • 50 LCapacity
  • 115 to 129 °CSterilization Temperature
  • 0.165 MPaSterilization Pressure
  • 320 × 610 mmChamber Dimension ( Φ × D )

Vertical Autoclave LVA-A14

  • 120 LCapacity
  • 480×660 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Autoclave LVA-F10

  • 50 LCapacity
  • 340 × 650 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Autoclave LVA-A15

  • 150 LCapacity
  • 510×740 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-L11
  • 85 LCapacity
  • 2Number of baskets
  • 105 °C to 138 °CSterilization temperature
  • 5 °C to 45 °CWorking environment temperature
Vertical Laboratory Autoclave LVA-C13
  • 100 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 440 × 650 mmChamber Dimension ( Φ × D )

Ethylene Oxide Sterilizer LEOS-A11

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 120 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A10

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 80 LCapacity
  • 50℃ ± 3℃Sterilization temperature
Ethylene Oxide Sterilizer LEOS-A12
  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 220 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-A11
  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal Laboratory Autoclave LHA-A10

  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Horizontal autoclave LHA-D18

  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure

Table Top

We deliver a wide range of Table Top autoclaves with user-friendly operating system and a capacity ranging from 20L to 50L. These are highly accurate, reliable and in compliance with Class N European Standards.

Tabletop Laboratory Autoclave LTTA-A12
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure
Tabletop Laboratory Autoclave LTTA-A11
  • 24 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure

Tabletop Laboratory Autoclave LTTA-A13

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure

Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-C11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C10
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 318 × 450 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C12
  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )

Portable Autoclave LPOA-A13

  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A12

  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Portable Autoclave LPOA-A11
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure