Vertical Laboratory Autoclave LVA-G10

Vertical Autoclave LVA-G10 has hand wheel type quick open door structure design. It is equipped with two stainless steel baskets and indicator light to indicate working status of sterilization process. Autoclave is top loading sterilizer with four wheels for easy movement of the unit and self-bulge seal ring to prevent leakage. Vertical autoclave has dual scale numerical pressure gauge system and provides auto protection against over temperature & over pressure. Its safe, economic and reliable autoclave with multiple applications in hospitals, clinical research laboratories, food industry, biotechnology & microbiology labs etc.

  • Capacity 35L
    Sterilization Temperature 134 °C
    Sterilization Pressure 0.22 Mpa
    Chamber Dimension ( Φ × D ) 318 × 450 mm
    Timer Range 0 - 99 min
    Number of sterilizing baskets 2
    Heat Average ≤ ± 1 ℃
    • Designed with horizontal sliding door with safety interlock device which do not allow door to open until there is no pressure in the chamber
    • Equipped with four wheels for easy movement of the unit and self-bulge seal ring to prevent leakage
    • Two stainless steel sterilizing baskets
    • Indicator light indicates working status
    • Automatic shutdown with beep sound after completion of process
    • Dual scale numerical pressure gauge
    • Safe inflating type seal
    • Safety valve and door locking system with pressure or temperature overloading protection device
  • Vertical autoclave with pressure steam has applications medicine and clinical research industry, pharmaceutical industry, biotechnology, microbiology and other organizations to sterilize biological material, culture media, surgical equipments, glass wares etc.

Related Products of Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-C13

  • 100 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 440 × 650 mmChamber Dimension ( Φ × D )

Vertical Autoclave LVA-B15

  • 150 LCapacity
  • 510 × 740 mmChamber volume
  • 134℃Working Temperature
  • 0.22 MPaWorking Pressure

Vertical Autoclave LVA-D10

  • 35 LCapacity
  • 318×450 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-D11
  • 50 LCapacity
  • 340×550 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-F13
  • 100 LCapacity
  • 440 × 650 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Autoclave LVA-B10

  • 35 LCapacity
  • 318 × 450 mmChamber volume
  • 134℃Working Temperature
  • 0.22 MPaWorking Pressure

Vertical Autoclave LVA-B11

  • 50 LCapacity
  • 340 × 550 mmChamber volume
  • 134℃Working Temperature
  • 0.22 MPaWorking Pressure

Vertical Laboratory Autoclave LVA-J11

  • 50 LCapacity
  • 115 to 129 °CSterilization Temperature
  • 0.165 MPaSterilization Pressure
  • 320 × 610 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-D13
  • 100 LCapacity
  • 440×650 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-F23
  • 35 LCapacity
  • 318 × 450 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Autoclave LVA-L20

  • 36 LCapacity
  • Diameter 325 × 460 mmChamber dimension
  • SUS 304Chamber material
  • (Diameter 300 × 200) × 2Stainless steel basket

Vertical Laboratory Autoclave LVA-I11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 320 × 610 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-I12

  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 388 × 530 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-A12
  • 75 LCapacity
  • 400×600 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Laboratory Autoclave LVA-K11
  • 80 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 396 × 650 mmChamber Dimension ( Φ × D )

Medical Autoclave

We offer Medical autoclave with user-friendly features which will not only sterilize the medical tools but can also be used for sterilizing medical waste prior to disposal with respect to the standards of municipal solid waste management.

Medical Autoclave LMA-A12

  • 23 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays

Medical Autoclave LMA-A10

  • 14 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays
Medical Autoclave LMA-A11
  • 17 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays
Portable Autoclave LPOA-A12
  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A13

  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A11

  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-C10
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 318 × 450 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C11
  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-C12

  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )

Table Top

We deliver a wide range of Table Top autoclaves with user-friendly operating system and a capacity ranging from 20L to 50L. These are highly accurate, reliable and in compliance with Class N European Standards.

Tabletop Laboratory Autoclave LTTA-A12

  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure
Tabletop Laboratory Autoclave LTTA-A11
  • 24 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure
Tabletop Laboratory Autoclave LTTA-A13
  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure

Ethylene Oxide Sterilizer LEOS-A10

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 80 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A12

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 220 LCapacity
  • 50℃ ± 3℃Sterilization temperature
Ethylene Oxide Sterilizer LEOS-A11
  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 120 LCapacity
  • 50℃ ± 3℃Sterilization temperature