Vertical Autoclave LVA-B10

Vertical Autoclave LVA-B10 is top loading vertical pressure steam sterilizer with chamber capacity of 35 L, working sterilization temperature and pressure of 134°C and 0.22 MPa respectively. Designed with digital display of working status, with touch keypad and double stainless steel baskets to keep the sterilization material load. Material used stainless high-alloy steel body structure. Auto discharge the cool air, and steam discharging automatically after sterilization. It is used in pharmaceutical industry, medicine and health care industry.

  • Capacity 35 L
    Chamber volume 318 × 450 mm
    Working Temperature 134℃
    Working Pressure 0.22 MPa
    Max Working Pressure 0.23 MPa
    Time Range 0 to 99 min or 0 to 99 hour 59 min
    Sterilization Temperature Range 105 to 134℃
    Heat Average ≤± 1℃
    Power Consumption 2.5 kW
    Power Supply AC 220 V, 50 Hz
    Overall Dimension 480 × 460 × 850 mm
    Packing Dimension 570 × 550 × 970 mm
    Net weight 42 kg
    Gross weight 56 kg
    • Material used for body structure is high-alloy stainless steel
    • Designed with digital display indicates working status, touch keypad control panel
    • Over temperature & over pressure auto-protection
    • Sterilization Temperature ranges from 105 to 134℃
    • Designed with auto discharge the cool air, and steam discharging automatically after sterilization
    • Automatically shut off with beep alarm after sterilization
    • Dual stainless steel baskets as standard accessory
    • Equipped with movable casters for easy movement
    • Easy to operate, safe and reliable
  • Vertical autoclave used in pharmaceutical industry, medicine and health care industry, Biotechnology, Microbiology for effective sterilization of glassware’s, biological materials, culture media and others.

  • Accessories no.Name MaterialQuantity
    1Basket Stainless steel02 pcs

Related Products of Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Autoclave LVA-L11

  • 85 LCapacity
  • 2Number of baskets
  • 105 °C to 138 °CSterilization temperature
  • 5 °C to 45 °CWorking environment temperature

Vertical Laboratory Autoclave LVA-K10

  • 60 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 396 × 490 mmChamber Dimension ( Φ × D )

Vertical Autoclave LVA-D13

  • 100 LCapacity
  • 440×650 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-L20
  • 36 LCapacity
  • Diameter 325 × 460 mmChamber dimension
  • SUS 304Chamber material
  • (Diameter 300 × 200) × 2Stainless steel basket
Vertical Laboratory Autoclave LVA-G11
  • 50LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-G12

  • 75LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )

Vertical Autoclave LVA-F22

  • 100 LCapacity
  • 440 × 650 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Autoclave LVA-F11

  • 75 LCapacity
  • 400 × 600 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Laboratory Autoclave LVA-I11
  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 320 × 610 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-K13
  • 120 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 504 x 404 x 590 mmChamber Dimension ( Φ × D )

Vertical Autoclave LVA-A10

  • 35 LCapacity
  • 318×450 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Autoclave LVA-D10

  • 35 LCapacity
  • 318×450 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Autoclave LVA-H10

  • 35 LCapacity
  • 134°CWorking sterilization temperature
  • 0.22 MPaWorking sterilization pressure
  • 105°C to 134°CAdjustment of Temperature
Vertical Laboratory Autoclave LVA-G13
  • 100LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 440 × 650 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-L12
  • 110 LCapacity
  • 3Number of baskets
  • 105 °C to 138 °CSterilization temperature
  • 5 °C to 45 °CWorking environment temperature

Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal autoclave LHA-D18

  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure

Horizontal Laboratory Autoclave LHA-A10

  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal Laboratory Autoclave LHA-A11
  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Ethylene Oxide Sterilizer LEOS-A12
  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 220 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A11

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 120 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A10

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 80 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Medical Autoclave

We offer Medical autoclave with user-friendly features which will not only sterilize the medical tools but can also be used for sterilizing medical waste prior to disposal with respect to the standards of municipal solid waste management.

Medical Autoclave LMA-A11
  • 17 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays
Medical Autoclave LMA-A10
  • 14 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays

Medical Autoclave LMA-A12

  • 23 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays

Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-C11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C12
  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C10
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 318 × 450 mmChamber Dimension ( Φ × D )

Portable Autoclave LPOA-A13

  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A11

  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Portable Autoclave LPOA-A12
  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure