Vertical Autoclave LVA-L10

Vertical Autoclave LVA-L10 is a 60 liter capacity fast speed microcomputer controlled unit with eight column evenly distributed mechanical interlocking system and cooling lock open temperature for sterilization. Inbuilt with automatic water feeding, cooling fan and drying mode for different types of sterilization cycles such as agar and solid with drying cycle. It consists of embedded steam collector and water tank with exhaust mode. Automatic protection with water level sensor, overpressure, cooling lock, dry scorch, temperature, safety valve, short circuit and anti-scald chamber leakage.

  • Capacity 60 L
    Number of baskets 2
    Sterilization temperature 105 °C to 138 °C
    Working environment temperature 5 °C to 45 °C
    Temperature accuracy 0.1 °C
    Sterilization time range 1 to 6000 minutes
    Melting temperature 45 °C to 60 °C
    Melting time range 1 to 9999 minutes
    Drying temperature 80 °C to 140 °C
    Drying time range 1 to 300 minutes
    Pressure gauge display -0.1 MPa to 0.5 MPa
    Maximum working pressure 0.27 MPa
    Design pressure 0.35 MPa
    Chamber material SUS 304
    Steam collector Embedded steam collector
    Water tank 28 L tank
    Sterilization cycle Solid, liquid, liquid with warming, agar, solid with drying, medical waste and customized cycles
    Sterilization cycle number Up to 60 cycles
    Power supply 2900 W
    Current supply 16 A
    Voltage supply AC 220 V, 50/60 Hz
    Chamber dimension (D × H) ɸ 400 mm × 505 mm
    Stainless steel basket dimension (D × H) (ɸ 360 mm × 200 mm) × 2
    Dimensions (L × W × H) 660 × 644 × 980 mm
    Packing Dimensions (L × W × H) 980 × 800 × 1230 mm
    Gross Weight 157 kg
    • Fast speed microcomputer intelligent control system
    • Eight column evenly distributed mechanical interlocking system
    • Drying mode consists of Automatic water feeding + cooling fan + drying
    • Specially designed for solid with drying function sterilization cycle
    • Sterilization cycle: Solid, liquid, liquid with warming, agar, solid with drying, medical waste and customized cycles
    • Sterilization cycle number: up to 60 cycles
    • Made up of SUS 304 chamber material
    • Up and Down lid opening type
    • Consist of auto start and preset range of timer
    • Water level sensor, leakage cooling lock, over pressure protection
    • Temperature monitor, anti-scald chamber and short circuit protection
    • Automatic internal discharging exhaust mode with steam collector bottle
    • Cooling lock open temperature feature
    • Easy to understand and operable control panel
  • Widely used in the applications of Biochemistry, pharmaceutical industry, medicine and health care industry, Biotechnology, Microbiology and scientific research.

  • No Accessory name
    1 Drainage Hose
    2 Water Plate
    3 Exhaust Bottle

Related Products of Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Autoclave LVA-H10

  • 35 LCapacity
  • 134°CWorking sterilization temperature
  • 0.22 MPaWorking sterilization pressure
  • 105°C to 134°CAdjustment of Temperature

Vertical Laboratory Autoclave LVA-I14

  • 120 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 460 × 670 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-I10

  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 280 × 500 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-F12
  • 35 LCapacity
  • 318 × 450 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-A12
  • 75 LCapacity
  • 400×600 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Laboratory Autoclave LVA-J12

  • 75 LCapacity
  • 115 to 129 °CSterilization Temperature
  • 0.165 MPaSterilization Pressure
  • 388 × 530 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-K12

  • 100 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 504 x 404 x 502 mmChamber Dimension ( Φ × D )

Vertical Autoclave LVA-F23

  • 35 LCapacity
  • 318 × 450 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Laboratory Autoclave LVA-J10
  • 35 LCapacity
  • 115 to 129 °CSterilization Temperature
  • 0.165 MPaSterilization Pressure
  • 280 × 500 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-G13
  • 100LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 440 × 650 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-C12

  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )

Vertical Autoclave LVA-F11

  • 75 LCapacity
  • 400 × 600 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Laboratory Autoclave LVA-K13

  • 120 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 504 x 404 x 590 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-I13
  • 100 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 388 × 670 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-J11
  • 50 LCapacity
  • 115 to 129 °CSterilization Temperature
  • 0.165 MPaSterilization Pressure
  • 320 × 610 mmChamber Dimension ( Φ × D )

Plasma Autoclave LPA-A10

  • 80 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply

Plasma Autoclave LPA-A11

  • 120 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply
Plasma Autoclave LPA-A12
  • 240 LCapacity
  • Rectangular, double doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply
Ethylene Oxide Sterilizer LEOS-A10
  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 80 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A12

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 220 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Ethylene Oxide Sterilizer LEOS-A11

  • Vertical; constant temperature heating box typeType
  • ManualDoor opening
  • 120 LCapacity
  • 50℃ ± 3℃Sterilization temperature

Table Top

We deliver a wide range of Table Top autoclaves with user-friendly operating system and a capacity ranging from 20L to 50L. These are highly accurate, reliable and in compliance with Class N European Standards.

Tabletop Laboratory Autoclave LTTA-A12
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure
Tabletop Laboratory Autoclave LTTA-A13
  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure

Tabletop Laboratory Autoclave LTTA-A11

  • 24 LCapacity
  • 134 °CSterilization Temperature
  • 105 to 134 °CAdjustment temperature
  • 0.22 MPaSterilization Pressure

Portable Autoclave LPOA-A12

  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Portable Autoclave LPOA-A11
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Portable Autoclave LPOA-A13
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-C10

  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 318 × 450 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-C11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C12
  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )