Drug Stability Test Chamber LDST-A11

Drug Stability Test Chamber LDST-A11 maintains a stable temperature and humidity condition by means of a highly advanced touch-screen controller and comes with a large LCD display showing temperature and humidity parameters.

  • Volume 250 L
    Temperature Range 0 - 65 °C
    Temperature Range(without illumination)
    Temperature Range(with illumination)
    Temperature Fluctuation ± 0.5 °C
    Temperature Control Precision 0.1 °C
    Humidity Range 40 - 98 % RH
    Illumination Intensity
    Internal Dimension 680 × 500 × 730 mm
    Overall Dimension 880 × 1010 × 1740 mm
    Power Supply AC 380 V ± 10 % 50 ± 0.5 Hz
    • Highly advanced temperature and humidity touch screen controller
    • 7 inch HD color LCD touch display
    • Real-time network monitoring and control functions
    • Sample shelves having adjustable height feature
    • Inner chamber made up of acid and corrosion resistant mirror finish SUS304 plate
    • High-quality door sealing strips and insulation materials for high performance
    • Shallow groove humidification method
    • Adopts automatic filling and standard water pump as water supply system
    • Water level automatic compensation and water shortage alarming system
    • PT100 platinum resistance thermometer as temperature sensor
    • Capacity to store around 1000 sections of programmes
    • Computer interface: Ethernet port
  • Drug Stability Test Chamber are used for a variety of applications like pharmaceutical and medical products package testing, stability and shelf-life testing.

Related Products of Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Drug Stability Test Chamber LDST-A21

  • 225 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Test Chamber LDST-A22

  • 500 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Test Chamber LDST-A23

  • 800 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time
Drug Stability Test Chamber LDST-A10
  • 150 LVolume
  • 0 - 65 °CTemperature Range
  • ± 0.5 °CTemperature Fluctuation
  • 0.1 °CTemperature Control Precision
Drug Stability Test Chamber LDST-A24
  • 1000 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Chamber with Illumination LDST-B11

  • 250 LVolume
  • 0 - 65 °CTemperature Range(without illumination)
  • 10 °C - 65°CTemperature Range(with illumination)
  • ± 0.5 °CTemperature Fluctuation

Drug Stability Test Chamber LDST-A20

  • 100 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Chamber with Illumination LDST-B12

  • 500 LVolume
  • 0 - 65 °CTemperature Range(without illumination)
  • 10 °C - 65°CTemperature Range(with illumination)
  • ± 0.5 °CTemperature Fluctuation
Drug Stability Chamber with Illumination LDST-B10
  • 150 LVolume
  • 0 - 65 °CTemperature Range(without illumination)
  • 10 °C - 65°CTemperature Range(with illumination)
  • ± 0.5 °CTemperature Fluctuation
Drug Stability Test Chamber LDST-A12
  • 500 LVolume
  • 0 - 65 °CTemperature Range
  • ± 0.5 °CTemperature Fluctuation
  • 0.1 °CTemperature Control Precision

UV Test Chamber

We manufacture UV test machine to simulate sunlight alongwith condenser and water spray system to simulate rain and dew. These chambers are used in various industries to detect the damage caused by environmental factors.

UV Test Chamber LUVC-A20

  • RT + 100 °C ~ 850 °CTemperature Range
  • At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %Humidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 V (135 V)Testing Voltage

UV Test Chamber LUVC-A21

  • RT + 100 °C ~ 630 °CTemperature Range
  • 30 % ~ 85 % RHHumidity range
  • 20 hoursTesting Time
  • 120 V ~ 145 VTesting Voltage
UV Test Chamber LUVC-A10
  • 50 °C to 75 °CUV Temperature
  • 48 piece (75 x 150 mm); 50 piece (75x 150 mm)Testing Capacity
  • 136 kgWeight
  • Distilled water, 8liters per dayWater Consumption

Drug Test Chamber

Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.

Drug Stability Test Chamber LDST-A22
  • 500 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Test Chamber LDST-A21

  • 225 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Drug Stability Test Chamber LDST-A20

  • 100 LInterior Volume
  • 1000 WHeat load
  • 0℃ to 100 ℃Temperature Range
  • ± 2.0 ℃Temperature Deviation in time

Temperature and Humidity Test Chamber

Labtron offers temperature and humidity test chambers which are used in various industries to test large equipments such as automotive parts by controlling the temperature and humidity. It is highly stable and provides enough space to work.

Temperature and Humidity Test Chamber LTHC-B10
  • 100 LCapacity
  • (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃Temperature range
  • 1 ℃ / minTemperature cooling rate
  • 860 x 1050 x 1620 mmOverall dimension (D x W x H)
Temperature and Humidity Test Chamber LTHC-A11
  • 80 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition

Temperature and Humidity Test Chamber LTHC-A10

  • 50 LCapacity
  • (- 20 °C) to 150 °CTemperature range
  • I – 40 °C, II – 70 °CLow type
  • 5 ℃ ~ + 40 ℃ ≤ 85 % RHEnvironmental condition

Ozone Test Chamber

Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.

Ozone Test Chamber LOC-A10

  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
  • ± 0.5 ℃Temperature fluctuation
  • Ambient ~ 0 ℃ within 20 minSpeed rate for cooling
Ozone Test Chamber LOC-A11
  • 400Diameter of holder (mm)
  • 180Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range
Ozone Test Chamber LOC-A12
  • 600Diameter of holder (mm)
  • 220Length of each side (mm)
  • 0℃ ~ 100℃Temperature range
  • 30 % - 98 % R.HHumidity range

Sand Test Chamber

In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.

Sand and Dust Test Chamber LSC-A11

  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire

Sand and Dust Test Chamber LSC-A12

  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire
Sand and Dust Test Chamber LSC-A10
  • Ambient to + 50 ℃Temperature range
  • < 30 % RHRelative Humidity
  • 50 umNormal wire diameter
  • 75 umNormal width of a gap between wire