Portable Airborne Particle Counter LPPC-A10

Portable airborne particle counter LPPC-A10 is a six channel microcomputer controlled unit. It has a provision of simultaneously counting particles in six different size ranges with real time monitoring. Equipped with built-in thermal sensitive printer for direct printing of pre-recorded and current data for end user convenience. The particle count data can be conveniently viewed, downloaded or printed directly using the built-in printer featuring multiple print mode.

  • Particle size channels 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
    Flow Rate 0.1 CFM ( 2.83 L/min )
    Test class Class 100 ∼ Class 300,000
    Built-in battery No
    Test period 1 min ∼ 10 min ( 10 levels )
    UCL Calculation 0.95
    Light source and life Semiconductor laser<hr> ( ˃ 30,000 hours )
    Self-clean time ≤ 10 min
    Operating temperature range 10 °C to 35 °C
    Operational humidity ≤ 75 % RH
    Battery type
    Battery life
    Power 220 V ± 10 %, 50 Hz ± 2 Hz
    Power dissipation 15 W
    Dimensions 215 x 255 x 110 mm
    Weight 2.6 kgs
    • Laser sensor based particle detection
    • Dual counting mode ( Auto/Manual )
    • Data conversion : ft3 and m3
    • Date and time display
  • Used in clean room monitoring, indoor air quality testing, filter testing, tracking particle sources, pharmaceuticals, R&D labs, and electronics and semiconductor industries; monitoring of biosafety cabinets, clean benches, computer rooms and HVAC system performance.

  • Accessory No Accessory Quantity
    1.        Aluminum alloy case 1
    2.        Power cord 1
    3.        Sampling rack 1
    4.        Printing paper 1
    5.        Fuse 1
    6.        Operating manual 1

Portable Airborne Particle Counter LPPC-A20

  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 1 CFM ( 28.3 L/min )Flow Rate
  • Class 100 ∼ Class 300,000Test class
  • 1 min ∼ 10 minTest period

Portable Airborne Particle Counter LPPC-A30

  • 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 (µm)Size channel
  • 28.3 L/minFlow rate
  • UCLTeat way
  • 1 to 40 minuteTest period

Portable Airborne Particle Counter LPPC-A11

  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 0.1 CFM ( 2.83 L/min )Flow Rate
  • Class 100 ∼ Class 300,000Test class
  • YesBuilt-in battery
Portable Airborne Particle Counter LPPC-B10
  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 1.0 CFM ( 28.3 L/min )Flow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )Test period
Portable Airborne Particle Counter LPPC-B12
  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 100 L/minFlow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )Test period

Portable Airborne Particle Counter LPPC-B11

  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 50 L/minFlow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 3599 sec ( 5 L ∼ 3000 L )Test period

Portable Airborne Particle Counter LPPC-A21

  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
    0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
    Particle size channels
  • 0.1 CFM ( 2.83 L/min )Flow Rate
  • Class 100 ∼ Class 300,000Test class
  • 1 min ∼ 10 minTest period

Dual Flow Particle Counter LDPC-A10

  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
    0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
    Particle size channels
  • 2.83 L/min
    50 mL/min
    Flow rates
  • 0.3 µmSensitivity
  • Class 100 ∼ Class 300,000Test class

Handheld Airborne Particle Counter LHPC-A11

  • 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µmParticle size channels
  • 0.1 CFM ( 2.83 L/min )Flow rate
  • Class 100 ∼ Class 300,000Test class
  • 1 min ∼ 15 min ( 15 levels )Test period
Handheld Airborne Particle Counter LHPC-A10
  • 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
    0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
    Particle size channels
  • 0.1 CFM ( 2.83 L/min )Flow rate
  • Class 100 ∼ Class 300,000Test class
  • 50 % at 0.3 µm
    100 % at 0.5 µm
    Counting efficiency
Dust Monitor LDMR-A10
  • PM10, PM2.5, PM1.0, TSPParticulate matter concentration
  • 15 channels, 0.3 to 25 µmParticulate channels and size
  • 0.0001 mg/m3Sensitivity
  • 0.01 to 20 mg/m3Measuring Range

Handheld Dust Meter LDMH-A10

  • PM 1.0, PM 2.5, and PM 10.0Measurement range
  • 0.1 µg/m3Resolution
  • 1000 µg/m3Concentration limits
  • 0.1Accuracy

Portable Airborne Particle Counter LPPC-B10

  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 1.0 CFM ( 28.3 L/min )Flow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )Test period
Portable Airborne Particle Counter LPPC-A30
  • 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 (µm)Size channel
  • 28.3 L/minFlow rate
  • UCLTeat way
  • 1 to 40 minuteTest period
Portable Airborne Particle Counter LPPC-B11
  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 50 L/minFlow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 3599 sec ( 5 L ∼ 3000 L )Test period