Dust Monitor LDMR-A10

Dust Monitor LDMR-A10 based on light scattering principle is a portable unit which counts as well determine the mass concentration of particulates. Additionally it displays battery levels, flow rate, pump details etc. on the screen. SD card slot and USB port are available to store and transfer data respectively. It is widely used in laboratories, research institutes, industries, quality control department etc.

  • Particulate matter concentration PM<sub>10</sub>, PM<sub>2.5</sub>, PM<sub>1.0</sub>, TSP
    Particulate channels and size 15 channels, 0.3 to 25 µm
    Sensitivity 0.0001 mg/m<sup>3</sup>
    Measuring Range 0.01 to 20 mg/m<sup>3</sup>
    Accuracy ± 10%
    Reproducibility ± 2%
    Flow Rate 1.0 to 2.83 L/min(Optional)
    Sample Time Arbitrary set
    Dimensions 160 × 115 × 200 mm
    Net Weight 2 kg
    • Based on Light scattering principle
    • Determines the number as well as mass concentration of particulates
    • Measures PM10, PM2.5, PM1.0, TSP
    • 15 channel particulate count of 0.3 to 25 µm size
    • High resolution touch screen
    • Easy to operate
    • Internal memory to store data
    • Li-ion battery which can last for 8 hrs
    • USB port to transfer data
    • Data logger incorporated can store 120000 samples
  • It is widely used in quality control department, to test air quality in industrial areas, laboratories, research institutes, mining industry etc.

Handheld Dust Meter LDMH-A10

  • PM 1.0, PM 2.5, and PM 10.0Measurement range
  • 0.1 µg/m3Resolution
  • 1000 µg/m3Concentration limits
  • 0.1Accuracy

Dual Flow Particle Counter LDPC-A10

  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
    0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
    Particle size channels
  • 2.83 L/min
    50 mL/min
    Flow rates
  • 0.3 µmSensitivity
  • Class 100 ∼ Class 300,000Test class

Handheld Airborne Particle Counter LHPC-A11

  • 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µmParticle size channels
  • 0.1 CFM ( 2.83 L/min )Flow rate
  • Class 100 ∼ Class 300,000Test class
  • 1 min ∼ 15 min ( 15 levels )Test period
Handheld Airborne Particle Counter LHPC-A10
  • 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
    0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
    Particle size channels
  • 0.1 CFM ( 2.83 L/min )Flow rate
  • Class 100 ∼ Class 300,000Test class
  • 50 % at 0.3 µm
    100 % at 0.5 µm
    Counting efficiency
Handheld Dust Meter LDMH-A10
  • PM 1.0, PM 2.5, and PM 10.0Measurement range
  • 0.1 µg/m3Resolution
  • 1000 µg/m3Concentration limits
  • 0.1Accuracy

Dust Monitor LDMR-A10

  • PM10, PM2.5, PM1.0, TSPParticulate matter concentration
  • 15 channels, 0.3 to 25 µmParticulate channels and size
  • 0.0001 mg/m3Sensitivity
  • 0.01 to 20 mg/m3Measuring Range

Portable Airborne Particle Counter LPPC-A30

  • 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 (µm)Size channel
  • 28.3 L/minFlow rate
  • UCLTeat way
  • 1 to 40 minuteTest period
Portable Airborne Particle Counter LPPC-B10
  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 1.0 CFM ( 28.3 L/min )Flow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )Test period
Portable Airborne Particle Counter LPPC-B11
  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 50 L/minFlow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 3599 sec ( 5 L ∼ 3000 L )Test period