Portable Airborne Particle Counter LPPC-A30

Portable Airborne Particle Counter LPPC-A30 is a six channel microcomputer controlled unit. It has a provision of simultaneously counting particles in six different size ranges with real time monitoring. Equipped with built-in thermal sensitive printer for direct printing of pre-recorded and current data for end user convenience. Designed with large LCD screen for displaying particle count of all channels. The particle count data can be conveniently viewed, downloaded or printed directly using the built-in printer featuring multiple print mode.

  • Size channel 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 (µm)
    Flow rate 28.3 L/min
    Teat way UCL
    Test period 1 to 40 minute
    Zero count < = 10 min
    Print mode Build-in Thermal Printer
    Continuously working time 8 h
    Light source and lifetime Long life laser diode with 3000h MTTF
    Display LCD
    Data storage 256 samples
    Dimension 370 × 440 × 126 mm
    Power consumption 80 W
    Power supply AC 220 V+/-10%, 50 Hz
    Weight 6 kg
    • Designed with large LCD screen for displaying particle count of all channels
    • It offers 6 size channels count
    • Sampling flow rate is up to 28.3 L/min
    • Equipped with computerized verification
    • Build in thermal printer
    • 1 CFM flow rate
    • Adopts 256 samples data storage
    • Designed with long life laser diode with 3000 h MTTF
  • Portable Airborne Particle Counter is used in clean room monitoring, indoor air quality testing, filter testing, tracking particle sources, pharmaceuticals, R&D labs, and electronics, semiconductor industries; monitoring of biosafety cabinets, clean benches, computer rooms and HVAC system performance; in fields of optics, aerospace, pharmaceutical, electronics, food hygiene industry, etc.

  • Accessories no.Name
    1Isokinetic probe
    2Sampling tubing
    3Sampling stent
    4Operator manual

Portable Airborne Particle Counter LPPC-B10

  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 1.0 CFM ( 28.3 L/min )Flow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )Test period

Portable Airborne Particle Counter LPPC-A20

  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 1 CFM ( 28.3 L/min )Flow Rate
  • Class 100 ∼ Class 300,000Test class
  • 1 min ∼ 10 minTest period

Portable Airborne Particle Counter LPPC-A21

  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
    0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
    Particle size channels
  • 0.1 CFM ( 2.83 L/min )Flow Rate
  • Class 100 ∼ Class 300,000Test class
  • 1 min ∼ 10 minTest period
Portable Airborne Particle Counter LPPC-A11
  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 0.1 CFM ( 2.83 L/min )Flow Rate
  • Class 100 ∼ Class 300,000Test class
  • YesBuilt-in battery
Portable Airborne Particle Counter LPPC-B12
  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 100 L/minFlow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )Test period

Portable Airborne Particle Counter LPPC-A10

  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 0.1 CFM ( 2.83 L/min )Flow Rate
  • Class 100 ∼ Class 300,000Test class
  • NoBuilt-in battery

Portable Airborne Particle Counter LPPC-B11

  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 50 L/minFlow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 3599 sec ( 5 L ∼ 3000 L )Test period

Dual Flow Particle Counter LDPC-A10

  • 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
    0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
    Particle size channels
  • 2.83 L/min
    50 mL/min
    Flow rates
  • 0.3 µmSensitivity
  • Class 100 ∼ Class 300,000Test class

Handheld Airborne Particle Counter LHPC-A10

  • 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm
    0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
    Particle size channels
  • 0.1 CFM ( 2.83 L/min )Flow rate
  • Class 100 ∼ Class 300,000Test class
  • 50 % at 0.3 µm
    100 % at 0.5 µm
    Counting efficiency
Handheld Airborne Particle Counter LHPC-A11
  • 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µmParticle size channels
  • 0.1 CFM ( 2.83 L/min )Flow rate
  • Class 100 ∼ Class 300,000Test class
  • 1 min ∼ 15 min ( 15 levels )Test period
Handheld Dust Meter LDMH-A10
  • PM 1.0, PM 2.5, and PM 10.0Measurement range
  • 0.1 µg/m3Resolution
  • 1000 µg/m3Concentration limits
  • 0.1Accuracy

Dust Monitor LDMR-A10

  • PM10, PM2.5, PM1.0, TSPParticulate matter concentration
  • 15 channels, 0.3 to 25 µmParticulate channels and size
  • 0.0001 mg/m3Sensitivity
  • 0.01 to 20 mg/m3Measuring Range

Portable Airborne Particle Counter LPPC-A30

  • 0.1, 0.2, 0.3, 0.5, 1.0, 5.0 (µm)Size channel
  • 28.3 L/minFlow rate
  • UCLTeat way
  • 1 to 40 minuteTest period
Portable Airborne Particle Counter LPPC-B11
  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 50 L/minFlow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 3599 sec ( 5 L ∼ 3000 L )Test period
Portable Airborne Particle Counter LPPC-B10
  • 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µmParticle size channels
  • 1.0 CFM ( 28.3 L/min )Flow Rate
  • 0.3 µmSensitivity
  • 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L )Test period