Microplate Reader LMPR-B10

Microplate Reader LMPR-B10 is used in ultraviolet-visible spectrophotometer with 96-well multimode UV-transmissive 96-well microplate optical system. Designed with flashing xenon lamp source, long life and stable illumination, the wavelength ranges from 190 nm to 1000 nm and offers 0 to 15.0 OD measurement range. It has single wavelength, dual wavelength and full wavelength detection functions and microplate oscillating mixing function. It offers quantitative or qualitative detection, a variety of calculation methods: absorbance mode, Cut-off qualitative calculation, linear regression, exponential regression and logistic regression. It is used for G protein coupled receptor detection and for protein quantitative analysis, support UV absorption, Bradford, Lowry and other methods. The special light absorption detection board can be used for calibration and calibration of the equipment also used in powerful data analysis software, microplate analysis and workstation.

  • Wavelength range 190 nm to 1000 nm
    Wavelength accuracy ±1.0 nm
    Wavelength repeatability ˂ 0.2 nm
    Resolution 0.001 Abs
    Display Value 0.000001 Abs
    Measurement range 0 to 15.0 OD
    Layout mode Visual free layout
    Incubation temperature Room Temperature + 2˚C to 65˚C
    Microplate type Standard 96-well microliter plate
    Display LCD touch
    Dimension 510 × 370 × 290 mm
    Packing Dimension 675 × 680 × 600 mm
    Net weight 21 kg
    Gross weight 45 kg
    • Designed with temperature control incubation system
    • It is used in ultraviolet-visible spectrophotometer
    • CCD real-time spectral scanning mode and real-time output of UV-visible spectrum
    • Detects any standard 96-well or UV-transmissive 96-well microplate
    • Designed with LCD touch display
    • Built-in grating monochromator
    • It offers incubation heating function
    • Wavelength ranges from 190 to 1000 nm
    • Equipped with single wavelength, dual wavelength and full wavelength detection functions
    • Microplate oscillating mixing function
    • Total antioxidant capacity test
    • Suitable for cell proliferation and cytotoxicity test
    • G protein coupled receptor detection
    • Designed with flashing xenon lamp source, long life and stable illumination
    • USB data interface to facilitate instrument control and data transmission
    • It detect the absorbance, concentration and purity of nucleic acids and proteins
    • The special light absorption detection board can be used for calibration and calibration of the equipment also used in powerful data analysis software, microplate analysis and workstation
    • Instrument parameter setting and instrument self-test function is highly automated
    • Suitable for end point method ELISA / EIA, with a variety of fitting curves for analysis
    • The software complies with IQ/OQ/PQ and FDA 21 CFR Part 11 certification
  • Microplate Reader is used in life science research work, especially DNA/RNA analysis, cell proliferation and cytotoxicity test, bacterial concentration analysis, pharmaceutical plant analysis, protease and kinase, phospholipase, NADH, GST activity test across used in end point method ELISA / EIA, with a variety of fitting curves for analysis.

Related Products of Microplate Reader

It features 96 well multimode and bichromatic multi-channel optical system. It offers high throughput with 3 shaking modes, fast reading speed of 5 seconds and malfunction alarm system. Different detection modes like comprehensive qualitative and quantitative data-evaluation functions with cut-offs, curve-fits and transformation formulas are available. It is a basic tool in drug discovery and life science research, bioassay testing and quality control pharmaceutical processes.

Microplate Reader LMPR-A10

  • 96-well platePlate Type
  • 7" TFT LCD DisplayDisplay
  • 400 to750 nmWavelength Range
  • 405, 450, 492, 630 nmStandard Wavelength

Microplate Reader LMPR-A12

  • controller tungsten halogen lampLight Source
  • 400 nm to 800 nmWavelength Range
  • 405, 450, 492, 630 nm and 4 optionalStandard Filters
  • 0.000 to 4.000 AbsReading range

Microplate Reader LMPR-A13

  • 8 V/50 W controller tungsten halogen lampLight Source
  • 400 nm to 850 nmWavelength Range
  • 405, 450, 492, 630 nm and 4 optionalStandard Filters
  • 0.000 to 4.000 AbsReading range
Microplate Reader LMPR-A15
  • 48-well,96-well microplatesPlate type
  • 8-inch industrial grade color LCD touch screen display; can display entire ELISA plate board informationDisplay
  • 400 to 800 nmWavelength range
  • 405 nm, 450 nm, 492 nm, 630 nm; can installed up to 10 filtersFilters
Microplate Reader LMPR-A14
  • 200 nm to 1000 nm with 1 nm stepsWavelength range
  • ±2 nmWavelength accuracy
  • MonochromatorWavelength selection
  • ˂ 2.5 nmHalf-bandwidth of filter

Microplate Reader LMPR-A30

  • 48/96-well platePlate type
  • 400-850 nmWavelength range
  • 405, 450, 492, 630 nmStandard filters
  • Filter wheel for up to 8 filtersAdditional filters

Microplate Reader LMPR-A20

  • 48/96-well platePlate Type
  • 400 to 850 nmWavelength Range
  • 405, 450, 492, 630 nmStandard Wavelength
  • Filter wheel for up to 8 filtersAdditional filters

Microplate Washer LMPW-A20

  • ≤ 1μL/wellResidual liquid
  • Plate mode and strip modeWash mode
  • 1 x 8 / 1 x 12Washing heads
  • 1-12 adjustableWash strip

Microplate Washer LMPW-A10

  • ≤ 1 µLResidual liquid
  • 1 × 8 or 1 × 12 headsWashing heads
  • Flat , U , V , C bottomPlate types
  • Sling-point, two-point and multi-pointWashing method

Microplate Reader

It features 96 well multimode and bichromatic multi-channel optical system. It offers high throughput with 3 shaking modes, fast reading speed of 5 seconds and malfunction alarm system. Different detection modes like comprehensive qualitative and quantitative data-evaluation functions with cut-offs, curve-fits and transformation formulas are available. It is a basic tool in drug discovery and life science research, bioassay testing and quality control pharmaceutical processes.

Microplate Reader LMPR-A14
  • 200 nm to 1000 nm with 1 nm stepsWavelength range
  • ±2 nmWavelength accuracy
  • MonochromatorWavelength selection
  • ˂ 2.5 nmHalf-bandwidth of filter
Microplate Reader LMPR-A13
  • 8 V/50 W controller tungsten halogen lampLight Source
  • 400 nm to 850 nmWavelength Range
  • 405, 450, 492, 630 nm and 4 optionalStandard Filters
  • 0.000 to 4.000 AbsReading range

Microplate Reader LMPR-A12

  • controller tungsten halogen lampLight Source
  • 400 nm to 800 nmWavelength Range
  • 405, 450, 492, 630 nm and 4 optionalStandard Filters
  • 0.000 to 4.000 AbsReading range