Microplate Reader LMPR-A15

Microplate Reader LMPR-A15 is a compact, benchtop ELISA microplate reader comprising silicon photocell detector, Halogen tungsten Lamp as light source, offers wavelength range of 400 to 750 nm. Features qualitative determination and quantitative analysis, 48-well and 96-well microplates, offers End point method, two-point method, dynamics, single / dual wavelength test mode. Adapted with unique open Cut-Off judgment formula, center positioning function, this equipment configures the inhibition rate measurement module. 8-inch industrial grade color LCD touch screen display, can display entire ELISA plate board information, allow user to monitor timely and print testing results directly through RS232 interface. Designed with professional software, large storage up to 200 group programs and 100000 sample results, and more than 10 curve fitting equations. With 3 linear vibration plate functions, this equipment offers 8 channel vertical light path system.

  • Plate type 48-well,96-well microplates
    Display 8-inch industrial grade color LCD touch screen display; can display entire ELISA plate board information
    Wavelength range 400 to 800 nm
    Filters 405 nm, 450 nm, 492 nm, 630 nm; can installed up to 10 filters
    Accuracy ≤±0.01 Abs
    Resolution 0.001Abs (display, print); inner calculating 0.0001Abs
    Repeatability ≤0.3%
    Stability ≤±0.003 Abs
    Optical path 8 channel vertical light path system
    Reading range 0 to 4.000 Abs
    Reading speed 6 s/96 well plate, single wavelength
    Vibration plate 3 kinds of linear vibration plate function; adjustable (0 to 255 sec)
    Light source Halogen-tungsten lamp; 12V/20W; ≥3000 hours
    Detector Silicon photocell detector
    Measurement mode Automatic Single-wavelength, dual-wavelength end point method
    Calculation mode Open type qualitative determination and quantitative analysis
    Software Professional software, large storage up to 200 group programs and 100000 sample results, and more than 10 curve fitting equations
    Interface RS232
    Power supply AC 110/220 V±10 %, 60/50 Hz
    Packaging dimensions (W×D×H) 550×395×470 mm
    Gross weight 16 kg
    • Compact, benchtop ELISA microplate reader
    • Silicon photocell detector; Halogen tungsten Lamp as light source
    • Open type qualitative determination and quantitative analysis
    • 48-well and 96-well microplates; Configures the inhibition rate measurement module
    • Offers End point method, two-point method, dynamics, single / dual wavelength test mode
    • Unique open Cut-Off judgment formula; Center positioning function
    • 8-inch industrial grade color LCD touch screen display, can display entire ELISA plate board information
    • Professional software, large storage up to 200 group programs and 100000 sample results, and more than 10 curve fitting equations
    • 3 linear vibration plate functions; 8 channel vertical light path system
    • RS232 printer interface
  • Microplate reader is widely used in the fields of hospital clinical diagnosis, immune pathology testing, microbial antigen and antibody detection, parasitic diseases diagnosis, blood disease diagnosis, endocrine disorder measure, plant diseases and insect, pets studies etc.

Related Products of Microplate Reader

It features 96 well multimode and bichromatic multi-channel optical system. It offers high throughput with 3 shaking modes, fast reading speed of 5 seconds and malfunction alarm system. Different detection modes like comprehensive qualitative and quantitative data-evaluation functions with cut-offs, curve-fits and transformation formulas are available. It is a basic tool in drug discovery and life science research, bioassay testing and quality control pharmaceutical processes.

Microplate Reader LMPR-A12

  • controller tungsten halogen lampLight Source
  • 400 nm to 800 nmWavelength Range
  • 405, 450, 492, 630 nm and 4 optionalStandard Filters
  • 0.000 to 4.000 AbsReading range

Microplate Reader LMPR-A30

  • 48/96-well platePlate type
  • 400-850 nmWavelength range
  • 405, 450, 492, 630 nmStandard filters
  • Filter wheel for up to 8 filtersAdditional filters

Microplate Reader LMPR-A14

  • 200 nm to 1000 nm with 1 nm stepsWavelength range
  • ±2 nmWavelength accuracy
  • MonochromatorWavelength selection
  • ˂ 2.5 nmHalf-bandwidth of filter
Microplate Reader LMPR-A13
  • 8 V/50 W controller tungsten halogen lampLight Source
  • 400 nm to 850 nmWavelength Range
  • 405, 450, 492, 630 nm and 4 optionalStandard Filters
  • 0.000 to 4.000 AbsReading range
Microplate Reader LMPR-A20
  • 48/96-well platePlate Type
  • 400 to 850 nmWavelength Range
  • 405, 450, 492, 630 nmStandard Wavelength
  • Filter wheel for up to 8 filtersAdditional filters

Microplate Reader LMPR-A10

  • 96-well platePlate Type
  • 7" TFT LCD DisplayDisplay
  • 400 to750 nmWavelength Range
  • 405, 450, 492, 630 nmStandard Wavelength

Microplate Reader LMPR-B10

  • 190 nm to 1000 nmWavelength range
  • ±1.0 nmWavelength accuracy
  • ˂ 0.2 nmWavelength repeatability
  • 0.001 AbsResolution

Microplate Reader

It features 96 well multimode and bichromatic multi-channel optical system. It offers high throughput with 3 shaking modes, fast reading speed of 5 seconds and malfunction alarm system. Different detection modes like comprehensive qualitative and quantitative data-evaluation functions with cut-offs, curve-fits and transformation formulas are available. It is a basic tool in drug discovery and life science research, bioassay testing and quality control pharmaceutical processes.

Microplate Reader LMPR-A12

  • controller tungsten halogen lampLight Source
  • 400 nm to 800 nmWavelength Range
  • 405, 450, 492, 630 nm and 4 optionalStandard Filters
  • 0.000 to 4.000 AbsReading range

Microplate Reader LMPR-A13

  • 8 V/50 W controller tungsten halogen lampLight Source
  • 400 nm to 850 nmWavelength Range
  • 405, 450, 492, 630 nm and 4 optionalStandard Filters
  • 0.000 to 4.000 AbsReading range
Microplate Reader LMPR-A14
  • 200 nm to 1000 nm with 1 nm stepsWavelength range
  • ±2 nmWavelength accuracy
  • MonochromatorWavelength selection
  • ˂ 2.5 nmHalf-bandwidth of filter
Microplate Washer LMPW-A10
  • ≤ 1 µLResidual liquid
  • 1 × 8 or 1 × 12 headsWashing heads
  • Flat , U , V , C bottomPlate types
  • Sling-point, two-point and multi-pointWashing method

Microplate Washer LMPW-A20

  • ≤ 1μL/wellResidual liquid
  • Plate mode and strip modeWash mode
  • 1 x 8 / 1 x 12Washing heads
  • 1-12 adjustableWash strip