Analytical HPLC System LAHS-B10

Analytical HPLC System LAHS-B10 is a unit equipped with LCD display UV-Visible wavelength range of 190 nm to 700 nm and double plunger reciprocating pump system for constant flow pump. It has isocratic kit system for test result accuracy. Consists of separate workstation, sample injector and front mounted self-locking switch. Deuterium lamp is used as light source with valve mounting frame. It is ideally used in the detection of compounds in pharmaceutical industries, research institute, food industries, and petroleum industries, etc.

  • High Pressure Constant Flow Pump
    • Double plunger reciprocating pump: 1 set
    • Flow range: 0.001 to 10.00 mL/min
    • Setting step size: 0.001 mL/min
    • Flow accuracy: ≤ ± 0.3 %
    • Flow stability: RSD ≤ 00.1 %
    • Maximum pressure: 42 MPa
    • Display pressure error: ≤ 1.0 %
    • Pressure fluctuation: ≤ 1.0 %
    • Power consumption: 80 W
    UV/Visible Detector
    • Wavelength range: 190 to 700 nm
    • Wavelength repeatability: ± 0.1 nm
    • Band width: 8 nm
    • Response time: 0 to 4.9 seconds
    • Linearity range: 1.8 AU (5 %)
    • Baseline Noise: ≤ ± 1 × 10<sup>-5</sup>AU
    • Baseline drift: ≤ 2.0 × 10<sup>-4</sup>AU/h
    • Minimum detectable concentration: 4.0 × 10<sup>-9</sup> g/mL
    • Detector cell: Optical path: 10 mm<hr> Volume: 10 µL
    • Light source: Deuterium lamp
    • Power consumption: 100 W
    • Voltage: AC 110 V/ 220 V ± 10 %, 50/60 Hz
    • Packing Dimensions (W × D × H): 600 × 440 × 380 mm<hr> 2 × (600 × 410 × 300 mm
    • Gross weight: 54 kg
    • Double plunger reciprocating pump system
    • Isocratic system kits
    • Sample injector: 1 set
    • Deuterium lamp light source
    • Separate workstation
    • LCD display for value observation
    • Front mounted self-locking switch
    • Output: USB port
    • Compact and easy to install
  • Widely used in pharmaceutical, petroleum, research institute, food industrial applications in separation and detection of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

  • No Accessory name
    1 Column oven

Analytical HPLC-A7840

  • {"Solvent delivery":"Double plunger series mode, floating plunger design, single stroke volume 30 \u00b5l","Pump Head":"10 ml stainless steel pump head","Flow rate range":"0.001 to 9.999 ml \/ min","Flow rate increment":"0.001 ml\/min","Maximum pressure":"42 MPa","Column size":"4.6 \u00d7 250 mm 5 \u00b5m","Pipeline Size":"1\/16 inch","Flow rate accuracy":"\u00b1 0.5 %","Flow rate precision":"RSD \u2264 0.1%","Gradient accuracy %":"\u00b1 0.5 %","Gradient repeatability %":"RSD \u2264 0.15%","GLP":"Automatic recording of pump sealing ring working time","Display":"LCD backlight display","Power":"80 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension":"398 \u00d7 149 \u00d7 267 mm"}Pump Specifications
  • {"Wavelength range":"190 to 700 nm","Wavelength accuracy":"\u00b1 1 nm","Wavelength repeatability":"0.2 nm","Deuterium lamp":"190 to 400 nm","Tungsten lamp":"400 to 700 nm","Baseline noise ( Static ) Au":"1 \u00d7 10-5<\/sup> AU\/h at 254 nm with methanol\/water= 80\/20","Baseline drift ( Static ) Au \/ h":"1.5 \u00d7 10-4<\/sup> AU\/h at 254 nm with methanol\/ water= 80\/20","Time constants":"16 grades adjustable","Display":"LCD backlight display","GLP":"Total number of lights, lamp replacement time and product serial number","Power":"75 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension (L \u00d7 W \u00d7 H)":"398 \u00d7 149 \u00d7 267 mm"}Detector Specifications

Analytical HPLC-A7835

  • {"Model No":"HPP-B1","Flow rate range":"0.0001 to 10 ml \/ min","Maximum pressure":"42 MPa , 0 to 5 ml \/ min","Column size":"4.6 \u00d7 250 mm","Sample size":"5 \u03bcm","Pressure pulsation":"\u2264 1.5 % at 10 MPa","Flow rate accuracy":"\u00b1 0.2 % at 1 ml \/ min","Flow rate repeatability %":"\u2264 0.15","Gradient accuracy %":"\u00b1 2","Gradient repeatability %":"\u2264 0.2","Dimension":"450 \u00d7 260 \u00d7 190 mm","Power supply":"90 V to 240 V","Weight":"11.2 kg"}Pump Specifications
  • {"Model No":"HPD-B2","Wavelength range":"190 to 800 nm","Wavelength accuracy":"\u00b1 0.75 nm","Wavelength repeatability":"0.2 nm","Band width":"8 nm","Optical path":"10 nm","Deuterium lamp":"190 to 400 nm","Tungsten lamp":"400 to 800 nm","Baseline noise ( Static ) Au":"\u2264 \u00b1 0.5 \u00d7 10 -5<\/sup>","Baseline drift ( Static ) Au \/ h":"\u2264 1.5 x 10 -4<\/sup>","Minimum detection limit":"\u2264 4 x 10 -8<\/sup>","Power":"100 W","Power supply":"90 V \/ 50 to 60 Hz","Dimension":"460 \u00d7 260 \u00d7 190 mm","Weight":"9.2 kg"}Detector Specifications

Analytical HPLC System LAHS-B11

  • {"Double plunger reciprocating pump":"2 sets","Flow range":"0.001 to 10.00 mL\/min","Setting step size":"0.001 mL\/min","Flow accuracy":"\u2264 \u00b1 0.3 %","Flow stability":"RSD \u2264 00.1 %","Maximum pressure":"42 MPa","Display pressure error":"\u2264 1.0 %","Pressure fluctuation":"\u2264 1.0 %","Power consumption":"80 W"}High Pressure Constant Flow Pump
  • {"Wavelength range":"190 to 700 nm","Wavelength repeatability":"\u00b1 0.1 nm","Band width":"8 nm","Response time":"0 to 4.9 seconds","Linearity range":"1.8 AU (5 %)","Baseline Noise":"\u2264 \u00b1 1 \u00d7 10-5<\/sup>AU","Baseline drift":"\u2264 2.0 \u00d7 10-4<\/sup>AU\/h","Minimum detectable concentration":"4.0 \u00d7 10-9<\/sup> g\/mL","Detector cell":"Optical path: 10 mm
    \nVolume: 10 \u00b5L","Light source":"Deuterium lamp","Power consumption":"100 W","Voltage":"AC 110 V\/ 220 V \u00b1 10 %, 50\/60 Hz","Packing Dimensions (W \u00d7 D \u00d7 H)":"600 \u00d7 440 \u00d7 380 mm
    \n3 \u00d7 (600 \u00d7 410 \u00d7 300 mm","Gross weight":"75 kg"}
    UV/Visible Detector
Analytical HPLC-A7832
  • Model No HPD-A20 HPD-A21
    Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
    Wavelength accuracy ± 0.5 nm ± 2 nm
    Wavelength repeatability 0.15 nm 0.3 nm
    Band width 8 nm 8 nm
    Optical path 10 nm 10 nm
    Deuterium lamp 190 to 400 nm 190 to 400 nm
    Tungsten lamp 400 to 800 nm 400 to 800 nm
    Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5
    Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4
    Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8
    Power 100 W 100 W
    Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz
    Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm
    Weight 9.5 kg 9.5 kg
    Detector Specifications
  • {"Flow rate range":"0.0001 to 10 ml \/ min","Maximum pressure":"50 MPa , 0 to 2 ml \/ min","Column size":"4.6 \u00d7 250 mm","Sample size":"5 \u00b5m","Pressure pulsation":"\u2264 1 % at 10 MPa","Flow rate accuracy":"\u00b1 0.15 % at 1 ml \/ min","Flow rate repeatability %":"\u2264 0.1","Gradient accuracy %":"\u00b1 1.5","Gradient repeatability %":"\u2264 0.2","Dimension":"460 \u00d7 310 \u00d7 180 mm","Power supply":"90 V","Weight":"11.6 kg"}Pump Specifications
Analytical HPLC System LAHS-A10
  • {"Type":"Quaternary Low Pressure Pump","Flow Rate Range":"0.001 to 10.000 ml\/min, in 0.001ml increments","Flow Accuracy":"\u2264 \u00b1 0.2% (1.00 ml\/min, H2 <\/sub>O, R.T., 8.5 MPa)","Flow Precision":"RSD \u2264 0.06% (1.00 ml\/min, H2 <\/sub>O, R.T., 8.5MPa)","Maximum Pressure":"63 MPa","Pressure accuracy":"\u2264 \u00b1 3.0 %","Pressure pulsation":"\u2264 0.1 MPa","Composition rang":"0 to 100 %","Composition precision":"\u2264 0.3 % RSD"}Pump specification
  • {"Wavelength Range":"190 to 800 nm","Wavelength Repeatability":"\u2264 0.1 nm","Wavelength Accuracy":"\u2264 \u00b1 1.0 nm","Band Width":"6 nm","Response Time":"0.0 s to 5 s","Baseline Noise":"\u2264 \u00b1 0.25 \u00d7 10-5 <\/sup> AU(empty cell, 254 nm, 1.0s)","Drift":"\u2264 0.5 \u00d7 10-4 <\/sup> AU\/h (empty cell, 254 nm, 60 min)","Path length":"10 mm(analytical cell)","Light Source":"Deuterium Lamp and Tungsten Lamp"}UV/VIS Detector
  • System contain the tables for regular samples
    Equipped with Internal and external standard calculation process
    Automatic display, print, export of data and starting of another program on completion on measurement
    Observe with the condition of 21 CFR part 11 directive of the FDA
    Data-processing Workstation
  • 1 Set
    Combined A/D converters
    Combined vacuum degasser and 4 channel
    System Kits

Analytical HPLC-A7840

  • {"Solvent delivery":"Double plunger series mode, floating plunger design, single stroke volume 30 \u00b5l","Pump Head":"10 ml stainless steel pump head","Flow rate range":"0.001 to 9.999 ml \/ min","Flow rate increment":"0.001 ml\/min","Maximum pressure":"42 MPa","Column size":"4.6 \u00d7 250 mm 5 \u00b5m","Pipeline Size":"1\/16 inch","Flow rate accuracy":"\u00b1 0.5 %","Flow rate precision":"RSD \u2264 0.1%","Gradient accuracy %":"\u00b1 0.5 %","Gradient repeatability %":"RSD \u2264 0.15%","GLP":"Automatic recording of pump sealing ring working time","Display":"LCD backlight display","Power":"80 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension":"398 \u00d7 149 \u00d7 267 mm"}Pump Specifications
  • {"Wavelength range":"190 to 700 nm","Wavelength accuracy":"\u00b1 1 nm","Wavelength repeatability":"0.2 nm","Deuterium lamp":"190 to 400 nm","Tungsten lamp":"400 to 700 nm","Baseline noise ( Static ) Au":"1 \u00d7 10-5<\/sup> AU\/h at 254 nm with methanol\/water= 80\/20","Baseline drift ( Static ) Au \/ h":"1.5 \u00d7 10-4<\/sup> AU\/h at 254 nm with methanol\/ water= 80\/20","Time constants":"16 grades adjustable","Display":"LCD backlight display","GLP":"Total number of lights, lamp replacement time and product serial number","Power":"75 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension (L \u00d7 W \u00d7 H)":"398 \u00d7 149 \u00d7 267 mm"}Detector Specifications

Analytical HPLC-A7835

  • {"Model No":"HPP-B1","Flow rate range":"0.0001 to 10 ml \/ min","Maximum pressure":"42 MPa , 0 to 5 ml \/ min","Column size":"4.6 \u00d7 250 mm","Sample size":"5 \u03bcm","Pressure pulsation":"\u2264 1.5 % at 10 MPa","Flow rate accuracy":"\u00b1 0.2 % at 1 ml \/ min","Flow rate repeatability %":"\u2264 0.15","Gradient accuracy %":"\u00b1 2","Gradient repeatability %":"\u2264 0.2","Dimension":"450 \u00d7 260 \u00d7 190 mm","Power supply":"90 V to 240 V","Weight":"11.2 kg"}Pump Specifications
  • {"Model No":"HPD-B2","Wavelength range":"190 to 800 nm","Wavelength accuracy":"\u00b1 0.75 nm","Wavelength repeatability":"0.2 nm","Band width":"8 nm","Optical path":"10 nm","Deuterium lamp":"190 to 400 nm","Tungsten lamp":"400 to 800 nm","Baseline noise ( Static ) Au":"\u2264 \u00b1 0.5 \u00d7 10 -5<\/sup>","Baseline drift ( Static ) Au \/ h":"\u2264 1.5 x 10 -4<\/sup>","Minimum detection limit":"\u2264 4 x 10 -8<\/sup>","Power":"100 W","Power supply":"90 V \/ 50 to 60 Hz","Dimension":"460 \u00d7 260 \u00d7 190 mm","Weight":"9.2 kg"}Detector Specifications
Analytical HPLC-A7832
  • Model No HPD-A20 HPD-A21
    Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
    Wavelength accuracy ± 0.5 nm ± 2 nm
    Wavelength repeatability 0.15 nm 0.3 nm
    Band width 8 nm 8 nm
    Optical path 10 nm 10 nm
    Deuterium lamp 190 to 400 nm 190 to 400 nm
    Tungsten lamp 400 to 800 nm 400 to 800 nm
    Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5
    Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4
    Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8
    Power 100 W 100 W
    Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz
    Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm
    Weight 9.5 kg 9.5 kg
    Detector Specifications
  • {"Flow rate range":"0.0001 to 10 ml \/ min","Maximum pressure":"50 MPa , 0 to 2 ml \/ min","Column size":"4.6 \u00d7 250 mm","Sample size":"5 \u00b5m","Pressure pulsation":"\u2264 1 % at 10 MPa","Flow rate accuracy":"\u00b1 0.15 % at 1 ml \/ min","Flow rate repeatability %":"\u2264 0.1","Gradient accuracy %":"\u00b1 1.5","Gradient repeatability %":"\u2264 0.2","Dimension":"460 \u00d7 310 \u00d7 180 mm","Power supply":"90 V","Weight":"11.6 kg"}Pump Specifications
HPLC system LHLC-A11
  • Two sets of pumpHigh pressure pump
  • 0.001 - 9.999 mL / min (0.001 mL / min increments)Flow rate range
  • ≤ 0.5 MPa (0 - 42 MPa)Pressure range
  • RSD < 0.06 %Flow rate precision

HPLC system LHLC-A10

  • Single pumpHigh pressure pump
  • 0.001 - 9.999 mL / min (0.001 mL / min increment)Flow rate range
  • ≤ 0.5 MPa (0 - 42 MPa)Pressure range
  • RSD < 0.06 %Flow rate precision

HPLC system LHLC-B11

  • High pressure constant-current infusion pumpHigh pressure pump
  • Micro volume series dual-pistonInfusion Way
  • 0 - 9999 PsiInfusion pressure
  • ≤ 0.5 %Flow rate