Spectral Colorimeter LCS-A12

Spectral colorimeter LCS-A12 with high precision, is adopted with spectral measurement working theory which greatly improves the accuracy of colorimeter. The superior leather design, helps in increasing the friction in case of fingers sliding. It comes with multiple light source for measurements & has metameric index, staining fastness, color fastness for color measurements in textile industry.

  • Illumination Di / 8 (diffusion illumination, 8° viewing), SCI
    Size of integrated sphere 40 mm, avian diffused reflection surface coating
    Illumination light source CLED
    Sensor Sensor array
    Wavelength 400 - 700 nm
    Spectral resolution 10 nm
    Measuring time 2 s
    Measurement caliber size 11 mm
    Optional measurement caliber size 4 mm, 6 mm, 15 mm
    Repeatability Standard deviation ΔE × ab 0.08 (when a white calibration plate is measured 30x at 10 second interval after calibration)
    Observe angles 2° and 10°
    Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF, U35
    Camera attachment camera viewing for measurement
    Display Chromaticity value(L × a × b,L × C × h), ΔE value, pass / fail, color tendency, average, generate test report<br/> With camera to see the measurement area, spectrum reflectance figure data, manual input target data
    Color difference formula ΔE × ab, ΔE × CH, ΔE × uv,ΔE × cmc(2:1),ΔE × cmc(1:1),ΔE × 94,ΔE × 00
    Color space CIE-L × a × b, L × C × h, L × uv, XYZ, Yxy, reflectance
    Measurement indices WI (whiteness indices)(ASTM E313-10,ASTM E313-73,CIE/ISO,AATCC,Hunter,Taube Berger,Ganz,Stensby)<br/> YI (yellowness indices) (ASTM D1925,ASTM E313-00,ASTM E313-73)<br/> Metameric index, staining fastness, color fastness
    Data storage 100 targets and 200 samples
    Light source lifetime 5 years, 1.5 million times
    Screen Panchromatic True Color Screen
    Interface USB 2.0
    Other function Input color swatches
    Working temperature 5 ~ 45 °C, relative humidity 80 % or below( at 35 °C ),no condensation
    Storage temperature (-25 to 55 °C), relative humidity 80 % or below( at 35 °C ),no condensation
    Power Rechargeable Lithium battery, 8.4 V / 2000 mAh, adaptor DC 12 V
    Dimension 77 × 86 × 210 mm
    Weight 550 g
    • CLED as source of diffusion illumination, 8° viewing
    • Panchromatic true color screen with USB 2.0 interface
    • Adopted with multiple source of light like A, C, D50, D65, D75, F1 - F12 etc.
    • Mass storage capacity of 100 pcs targets and 200 pcs samples
    • Ergonomic design, portable nature
    • Adapted with Camera for viewing measurement area
    • Patented technology guarantees the measurement stability
  • Spectral colorimeter is widely used for plastic, printing, paint, ink, textile, dyeing, food, chemical and other industries for color management.

  • Micro printer

Spectral Colorimeter LCS-A10

  • Di / 8 (diffusion illumination, 8° viewing), SCIIllumination
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Sensor arraySensor

Spectral Colorimeter LCS-A11

  • Di / 8 (diffusion illumination, 8° viewing), SCIIllumination
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Sensor arraySensor

Color & Haze meter LHM-A11

  • CIE-A,CIE-C,CIE-D65 Chromaticity Value:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84Light source
  • ASTM D1003/D1044,ISO13468/ISO14782 & CIE No.15,ISO 7724/1,ASTM E1164Standards
  • HAZE, Transmittance(T),Spectral Transmittance
    Whiteness Index (ASTM E313-00,ASTM E313-73,CIE/ISO AATCC,Hunter, Taube Berger Stensby) Yellowness Index (ASTM D1925,ASTM E313-00,ASTM E313-73)
    Tint(ASTM E313-00), Metamerism Index, Milm APHA, Pt-Co, Gardner, Color Difference(ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00)
    Parameters
  • CIE Luminosity function ySpectral response

Haze meter LHM-A10

  • CIE-A, CIE-C, CIE-D65Light source
  • ASTM D1003/D1044 & ISO13468/ISO14782Standards
  • HAZE, Transmittance(T)Parameters
  • CIE Luminosity function ySpectral response
Spectral Colorimeter LCS-A12
  • Di / 8 (diffusion illumination, 8° viewing), SCIIllumination
  • 40 mm, avian diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Sensor arraySensor
Spectral Colorimeter LCS-A10
  • Di / 8 (diffusion illumination, 8° viewing), SCIIllumination
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Sensor arraySensor

Spectral Colorimeter LCS-A11

  • Di / 8 (diffusion illumination, 8° viewing), SCIIllumination
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Sensor arraySensor

Colorimeter LCC-A12

  • Camera viewing system for measurementCharacteristic function
  • 8°/d (diffusion illumination), SCI (spectral components included)Illumination system
  • Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values
    Color difference values: △(L × a × b),△(L × C × h)
    Whiteness values: hunter whiteness, Ganz whiteness
    Yellowness value: YI
    Display mode
  • 2.4 inch LCD display screenDisplay screen
Colorimeter LCC-A10
  • Color cardColor measurement method
  • 8°/d (diffusion illumination), SCI (spectral components included)Illumination system
  • Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values
    Color difference values: △(L × a × b),△(L × C × h)
    Whiteness values: hunter whiteness, Ganz whiteness
    Yellowness value: YI
    Display mode
  • 2.4 inch LCD display screenDisplay screen
Colorimeter LCC-A11
  • 8°/d (diffusion illumination), SCI (spectral components included)Illumination system
  • Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values
    Color difference values: △(L × a × b),△(L × C × h)
    Whiteness values: hunter whiteness, Ganz whiteness
    Yellowness value: YI
    Display mode
  • 2.4 inch LCD display screenDisplay screen
  • About 8 mmMeasuring calibration

Colorimeter LCOM-A10

  • 420 to 660 nmWavelength Range
  • 420 nm , 470 nm ,530 nm ,620 nm , 660 nmFilter
  • ± 5 nmHigh stability and reproducibility
  • Consumes only 1.5ml of reagentEconomy