Haze meter LHM-A10

Haze meter LHM-A10 is used for haze and transmittance measurement. It has open measurement area with no limit on sample size, can carry out vertical measurements as well. It comes with different light sources such as A, C, D65 etc. for haze, transmittance measurement. Design confirms to ASTM & ISO standards, where transmittance compensation measurement provides high accuracy test result.

  • Light source CIE-A, CIE-C, CIE-D65
    Standards ASTM D1003/D1044 & ISO13468/ISO14782
    Parameters HAZE, Transmittance(T)
    Spectral response CIE Luminosity function y
    Wavelength 400 to 700 nm
    Wavelength interval 10 nm
    Geometry 0/d
    Measurement area/sample port 16.5 mm/ 21 mm
    Measurement range 0 to 100 %
    Haze resolution 0.01
    Haze responsibility ≤ 0.1
    Sample size Thickness ≤ 145 mm
    Display 5.0 inch TFT touch LCD screen
    Memory 20000 value
    Interface USB
    Power 220 V with power cable
    Working temperature 0 to 45 °C, Relative humidity 80% or below (at 35 ° C), no condensation
    Storage temperature 0 to 50 °C
    Dimension (L × W × H) 598 × 247 × 366 mm
    • 5.0 inch TFT touch screen display interface
    • Different light sources A,C, D65 etc. for haze, transmittance measurement
    • Open measurement area with no limit on sample size
    • Confirms to ASTM & ISO haze measurement standard
    • Equipped with software for haze and transmittance
    • Different parameters can be tested like Haze, Transmittance, and Yellowness & Whiteness Index etc.
    • Large storage capacity 100 test samples , 200 measurement records for each sample
  • Haze meter has applications in haze and transmittance measurement of anti-glare plastic sheets, films, glass, LCD panel screens used for TV screen, car navigation screen, computer screen, mobile phone cover & other transparent & semi-transparent material color.

Color & Haze meter LHM-A11

  • CIE-A,CIE-C,CIE-D65 Chromaticity Value:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84Light source
  • ASTM D1003/D1044,ISO13468/ISO14782 & CIE No.15,ISO 7724/1,ASTM E1164Standards
  • HAZE, Transmittance(T),Spectral Transmittance
    Whiteness Index (ASTM E313-00,ASTM E313-73,CIE/ISO AATCC,Hunter, Taube Berger Stensby) Yellowness Index (ASTM D1925,ASTM E313-00,ASTM E313-73)
    Tint(ASTM E313-00), Metamerism Index, Milm APHA, Pt-Co, Gardner, Color Difference(ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00)
    Parameters
  • CIE Luminosity function ySpectral response

Colorimeter LCOM-A10

  • 420 to 660 nmWavelength Range
  • 420 nm , 470 nm ,530 nm ,620 nm , 660 nmFilter
  • ± 5 nmHigh stability and reproducibility
  • Consumes only 1.5ml of reagentEconomy

Colorimeter LCC-A10

  • Color cardColor measurement method
  • 8°/d (diffusion illumination), SCI (spectral components included)Illumination system
  • Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values
    Color difference values: △(L × a × b),△(L × C × h)
    Whiteness values: hunter whiteness, Ganz whiteness
    Yellowness value: YI
    Display mode
  • 2.4 inch LCD display screenDisplay screen
Colorimeter LCC-A12
  • Camera viewing system for measurementCharacteristic function
  • 8°/d (diffusion illumination), SCI (spectral components included)Illumination system
  • Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values
    Color difference values: △(L × a × b),△(L × C × h)
    Whiteness values: hunter whiteness, Ganz whiteness
    Yellowness value: YI
    Display mode
  • 2.4 inch LCD display screenDisplay screen
Colorimeter LCC-A11
  • 8°/d (diffusion illumination), SCI (spectral components included)Illumination system
  • Colorimetric values: L × a × b,L × C × h,△E × ab,XYZ,relative RGB values
    Color difference values: △(L × a × b),△(L × C × h)
    Whiteness values: hunter whiteness, Ganz whiteness
    Yellowness value: YI
    Display mode
  • 2.4 inch LCD display screenDisplay screen
  • About 8 mmMeasuring calibration

Spectral Colorimeter LCS-A10

  • Di / 8 (diffusion illumination, 8° viewing), SCIIllumination
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Sensor arraySensor

Spectral Colorimeter LCS-A12

  • Di / 8 (diffusion illumination, 8° viewing), SCIIllumination
  • 40 mm, avian diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Sensor arraySensor
Spectral Colorimeter LCS-A11
  • Di / 8 (diffusion illumination, 8° viewing), SCIIllumination
  • 40 mm, alvan diffused reflection surface coatingSize of integrated sphere
  • CLEDIllumination light source
  • Sensor arraySensor
Color & Haze meter LHM-A11
  • CIE-A,CIE-C,CIE-D65 Chromaticity Value:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84Light source
  • ASTM D1003/D1044,ISO13468/ISO14782 & CIE No.15,ISO 7724/1,ASTM E1164Standards
  • HAZE, Transmittance(T),Spectral Transmittance
    Whiteness Index (ASTM E313-00,ASTM E313-73,CIE/ISO AATCC,Hunter, Taube Berger Stensby) Yellowness Index (ASTM D1925,ASTM E313-00,ASTM E313-73)
    Tint(ASTM E313-00), Metamerism Index, Milm APHA, Pt-Co, Gardner, Color Difference(ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00)
    Parameters
  • CIE Luminosity function ySpectral response

Haze meter LHM-A10

  • CIE-A, CIE-C, CIE-D65Light source
  • ASTM D1003/D1044 & ISO13468/ISO14782Standards
  • HAZE, Transmittance(T)Parameters
  • CIE Luminosity function ySpectral response