Vertical Autoclave LVA-L12

Vertical Autoclave LVA-L12 is a 110 liter capacity fast speed microcomputer controlled unit with eight column evenly distributed mechanical interlocking system and cooling lock open temperature for sterilization. Inbuilt with automatic water feeding, cooling fan and drying mode for different types of sterilization cycles such as agar and solid with drying cycle. It consists of embedded steam collector and water tank with exhaust mode. Automatic protection with water level sensor, overpressure, cooling lock, dry scorch, temperature, safety valve, short circuit and anti-scald chamber leakage.

  • Capacity 110 L
    Number of baskets 3
    Sterilization temperature 105 °C to 138 °C
    Working environment temperature 5 °C to 45 °C
    Temperature accuracy 0.1 °C
    Sterilization time range 1 to 6000 minutes
    Melting temperature 45 °C to 60 °C
    Melting time range 1 to 9999 minutes
    Drying temperature 80 °C to 140 °C
    Drying time range 1 to 300 minutes
    Pressure gauge display -0.1 MPa to 0.5 MPa
    Maximum working pressure 0.27 MPa
    Design pressure 0.35 MPa
    Chamber material SUS 304
    Steam collector Embedded steam collector
    Water tank 28 L tank
    Sterilization cycle Solid, liquid, liquid with warming, agar, solid with drying, medical waste and customized cycles
    Sterilization cycle number Up to 60 cycles
    Power supply 4600 W
    Current supply 32 A
    Voltage supply AC 220 V, 50/60 Hz
    Chamber dimension (D × H) ɸ 400 mm × 895 mm
    Stainless steel basket dimension (D × H) (ɸ 360 mm × 250 mm) × 3
    Dimensions (L × W × H) 660 × 644 × 1180 mm
    Packing Dimensions (L × W × H) 980 × 800 × 1430 mm
    Gross Weight 182 kg
    • Fast speed microcomputer intelligent control system
    • Eight column evenly distributed mechanical interlocking system
    • Drying mode consists of Automatic water feeding + cooling fan + drying
    • Specially designed for solid with drying function sterilization cycle
    • Sterilization cycle: Solid, liquid, liquid with warming, agar, solid with drying, medical waste and customized cycles
    • Sterilization cycle number: up to 60 cycles
    • Made up of SUS 304 chamber material
    • Up and Down lid opening type
    • Consist of auto start and preset range of timer
    • Water level sensor, leakage cooling lock, over pressure protection
    • Temperature monitor, anti-scald chamber and short circuit protection
    • Automatic internal discharging exhaust mode with steam collector bottle
    • Cooling lock open temperature feature
    • Easy to understand and operable control panel
  • Widely used in the applications of Biochemistry, pharmaceutical industry, medicine and health care industry, Biotechnology, Microbiology and scientific research.

  • No Accessory name
    1 Drainage Hose
    2 Water Plate
    3 Exhaust Bottle

Related Products of Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Autoclave LVA-F23

  • 35 LCapacity
  • 318 × 450 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Laboratory Autoclave LVA-I14

  • 120 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 460 × 670 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-K11

  • 80 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 396 × 650 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-D13
  • 100 LCapacity
  • 440×650 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure
Vertical Autoclave LVA-L21
  • 54 LCapacity
  • Diameter 325 × 460 mmChamber dimension
  • SUS 304Chamber material
  • (Diameter 300 × 200) × 3Stainless steel basket

Vertical Autoclave LVA-D10

  • 35 LCapacity
  • 318×450 mmChamber Volume
  • 134°CWorking Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Laboratory Autoclave LVA-J10

  • 35 LCapacity
  • 115 to 129 °CSterilization Temperature
  • 0.165 MPaSterilization Pressure
  • 280 × 500 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-G11

  • 50LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-K13
  • 120 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MPaSterilization Pressure
  • 504 x 404 x 590 mmChamber Dimension ( Φ × D )
Vertical Autoclave LVA-B14
  • 120 LCapacity
  • 480 × 660 mmChamber volume
  • 134℃Working Temperature
  • 0.22 MPaWorking Pressure

Vertical Laboratory Autoclave LVA-I12

  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 388 × 530 mmChamber Dimension ( Φ × D )

Vertical Autoclave LVA-F21

  • 75 LCapacity
  • 400 × 600 mmChamber volume
  • 134℃Working Sterilization Temperature
  • 0.22 MPaWorking Sterilization Pressure

Vertical Laboratory Autoclave LVA-G12

  • 75LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C12
  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C11
  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )

Portable Autoclave LPOA-A12

  • 24 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure

Portable Autoclave LPOA-A11

  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically / LPG heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Portable Autoclave LPOA-A13
  • 18 LVolume of Chamber
  • 126 ℃Working temperature
  • Electrically heatedHeating mode
  • 0.14 ~ 0.16 MPaWorking pressure
Plasma Autoclave LPA-A11
  • 120 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply

Plasma Autoclave LPA-A12

  • 240 LCapacity
  • Rectangular, double doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply

Plasma Autoclave LPA-A10

  • 80 LCapacity
  • Rectangular, single doorDoor type
  • Anti rust aluminum alloyChamber material
  • 3 kW / 220 V, Single phasePower supply

Medical Autoclave

We offer Medical autoclave with user-friendly features which will not only sterilize the medical tools but can also be used for sterilizing medical waste prior to disposal with respect to the standards of municipal solid waste management.

Medical Autoclave LMA-A12
  • 23 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays
Medical Autoclave LMA-A11
  • 17 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays

Medical Autoclave LMA-A10

  • 14 LCapacity
  • 4 - 18 minsSterilization Time
  • 121 °C / 134 °CSterilization Temperature
  • 3No. of Trays

Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal autoclave LHA-D18

  • 120 LCapacity
  • 105 °C to 134 °CWorking temperature
  • 139 °CSterilization temperature
  • 0.245 MPaSterilization pressure
Horizontal Laboratory Autoclave LHA-A10
  • 300 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range
Horizontal Laboratory Autoclave LHA-A11
  • 500 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 0 - 99 minutesTimer Range

Vertical Autoclave

Labtron Vertical autoclaves are manufactured keeping in mind the client’s requirements in research laboratories, hospitals & clinics and food & beverage sectors. These units are equipped with dual scale numerical pressure gauge to indicate temperature and pressure of the system.

Vertical Laboratory Autoclave LVA-C11

  • 50 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 340 × 550 mmChamber Dimension ( Φ × D )

Vertical Laboratory Autoclave LVA-C12

  • 75 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 400 × 600 mmChamber Dimension ( Φ × D )
Vertical Laboratory Autoclave LVA-C10
  • 35 LCapacity
  • 134 °CSterilization Temperature
  • 0.22 MpaSterilization Pressure
  • 318 × 450 mmChamber Dimension ( Φ × D )